Skip to main content

FQXSPUN0055M : The RAID controller in PCI slot [arg1] is in critical state. Battery is in non-optimal state.

The RAID controller in PCI slot [arg1] is in critical state. Battery is in non-optimal state.

This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

Severity​

Error

Alert Category​

Critical - Other

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0522

SNMP Trap ID​

50

Automatically Notify Support​

No

User Action​

Complete the following steps until the problem is solved:

  1. Check whether a RAID battery is installed and attached.
  2. If no RAID battery is installed, please ignore this message.
  3. If a RAID battery is installed, check the RAID battery for air flow obstruction and ensure that battery cables are properly connected.
  4. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.