Specifications

The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.

Table 1. Server specifications
SpecificationDescription

Dimension

  • Form factor: 1U

  • Height: 43.0 mm (1.7 inches)

  • Width:
    • With rack latches: 482.0 mm (19.0 inches)

    • Without rack latches: 434.4 mm (17.1 inches)

  • Depth: 778.3 mm (30.7 inches)
    Note
    The depth is measured with rack latches and power supply installed, but without security bezel installed.

Weight

Up to 16.0 kg (35.3 lb), depending on your configuration

Processor (depending on the model)

  • Up to two Intel® Xeon® Scalable Processors
    • Designed for Land Grid Array (LGA) 3647 socket

    • Scalable up to 20 cores

For a list of supported processors, see: Lenovo ServerProven website

Memory

For 1st Generation Intel Xeon Scalable Processor (SP Gen 1) :

  • Minimum: 8 GB

  • Maximum:
    • 384 GB using registered DIMMs (RDIMMs)

    • 768 GB using load-reduced DIMMs (LRDIMMs)

  • Type (depending on the model):

    • TruDDR4 2666, single-rank or dual-rank, 8 GB/16 GB/32 GB RDIMMs

    • TruDDR4 2666, quad-rank, 64 GB LRDIMMs

  • Slots: 12 slots

For 2nd Generation Intel Xeon Scalable Processor (SP Gen 2):

  • Minimum: 8 GB

  • Maximum: 768 GB

  • Type (depending on the model):

    • TruDDR4 2666, single-rank or dual-rank, 16 GB/32 GB RDIMMs

    • TruDDR4 2933, single-rank or dual-rank, 8 GB/16 GB/32 GB/64 GB RDIMMs

  • Slots: 12 slots

Note
List of supported memory module is different for 1st generation (Skylake) and 2nd generation (Cascade Lake) Intel Xeon processors. Make sure to install compatible memory modules to avoid system error.For a list of supported DIMMs, see: Lenovo ServerProven website.
Operating systemsSupported and certified operating systems:
  • Microsoft Windows Server

  • VMware ESXi

  • Red Hat Enterprise Linux

  • SUSE Linux Enterprise Server

For a complete list of operating systems, see:

OS Interoperability Guide

For OS deployment instructions, see: Deploy the operating system.

Internal drives

Drives supported by your server vary by model.
  • Up to four 3.5-inch hot-swap SAS/SATA drives

  • Up to four 3.5-inch simple-swap SATA drives

  • Up to eight 2.5-inch hot-swap SAS/SATA drives

  • Up to two M.2 drives

PCIe slots

Depending on the server model, your server supports up to three PCIe slots.

For more information about the PCIe slots, see Rear view.

Input/Output (I/O) features

  • Front panel:
    • One VGA connector*

    • One XClarity Controller USB connector

    • One USB 3.0 connector

  • Rear panel:
    • One VGA connector

    • Two USB 3.0 connectors

    • Two Ethernet connectors (RJ-45)

    • One XClarity Controller network connector

    • Two Ethernet connectors on the LOM adapter*

    • One serial port*

* Available on some models

Storage controller

  • SAS/SATA HBA adapters

    • ThinkSystem 430-8i SAS/SATA 12Gb HBA

    • ThinkSystem 430-8e SAS/SATA 12Gb HBA

    • ThinkSystem 430-16e SAS/SATA 12Gb HBA

    • ThinkSystem 440-8e SAS/SATA PCIe Gen4 12Gb HBA

    • ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA

    • ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA

    • ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA

  • SAS/SATA RAID adapters

    • ThinkSystem RAID 530-8i PCIe 12Gb Adapter

    • ThinkSystem RAID 540-8i PCIe 12Gb Adapter

    • ThinkSystem RAID 730-8i 1GB Adapter

    • ThinkSystem RAID 730-8i 2GB PCIe Adapter

    • ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter

    • ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter

    • ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter

    • ThinkSystem RAID 940-8e 4GB Flash PCIe 12Gb Adapter

    • ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter

    • ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter

    • ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter

    • ThinkSystem RAID 5350-8i PCIe 12Gb Adapter

    • ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter

Note
  • RAID 730-8i 1G Cache SAS/SATA adapter is not available for North America.

  • If RAID 730-8i 1GB/2GB Cache SAS/SATA adapter is installed, ThinkSystem 2.5" PM1653/PM1655 Read Intensive/Mixed Use SAS 24Gb SSD cannot be installed.

  • RAID 530-8i SAS/SATA adapter cannot be mixed with RAID 730-8i 1G Cache SAS/SATA adapter.

  • RAID 730-8i 2G Flash SAS/SATA adapter cannot be mixed with RAID 730-8i 1G Cache SAS/SATA adapter or RAID 930-8i SAS/SATA adapter.

  • The RAID 940 adapters can be mixed with the ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA and the ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA.

  • Mixing of RAID/HBA 430/530/730/930 adapters (Gen 3) and RAID/HBA 440/540/940 adapters (Gen 4) in the same system is not allowed.

  • RAID 930/940 series or 9350 series adapters require a RAID flash power module.

  • RAID 5350/9350 series adapters cannot be mixed with HBA/RAID 430/440/530/540/730/930/940 series SAS/SATA adapters.

System fans

  • One processor: four system fans

  • Two processors: six system fans

Note
  • If your server is installed with one processor, four system fans (fan 1 to fan 4) are adequate to provide proper cooling. However, you must keep the locations for fan 5 and fan 6 occupied by fan fillers to ensure proper airflow.

  • When the system is powered off but still plugged in to AC power, fans 1 and 2 may continue to spin at a much lower speed. This is the system design to provide proper cooling.

Power supplies

Up to two hot-swap power supplies for redundancy support.
  • 550-watt ac 80 PLUS Platinum

  • 750-watt ac 80 PLUS Platinum

  • 750-watt ac 80 PLUS Titanium

Acoustical noise emissions

  • Sound power levels, idle

    • 4.5 bels, minimum

    • 4.6 bels, typical

    • 5.2 bels, maximum

  • Sound power levels, operating

    • 5.0 bels, minimum

    • 5.1 bels, typical

    • 5.5 bels, maximum

Note
  • These sound power levels are measured in controlled acoustical environments according to procedures specified by ISO 7779 and are reported in accordance with ISO 9296.

  • The declared acoustic noise levels are based on specified configurations and they may change depending on configurations/conditions.

  • The declared acoustic noise levels may increase greatly, if high-power components are installed, for example, some high-power NICs, CPUs, and GPUs.

Electrical input

  • Sine-wave input (50–60 Hz) required

  • Input voltage low range
    • Minimum: 100 V ac

    • Maximum: 127 V ac

  • Input voltage high range:
    • Minimum: 200 V ac

    • Maximum: 240 V ac

Note
For server models with 750-watt ac 80 PLUS Titanium power supplies, the 100–127 V ac input voltage is not supported.
CAUTION
  • 240 V dc input (input range: 180-300 V dc) is supported in Chinese Mainland ONLY. Power supply with 240 V dc input cannot support hot plugging power cord function. Before removing the power supply with dc input, please turn off server or disconnect dc power sources at the breaker panel or by turning off the power source. Then, remove the power cord.

  • In order for the ThinkSystem products to operate error free in both a DC or AC electrical environment, a TN-S earthing system which complies to 60364-1 IEC 2005 standard has to be present or installed.

Minimal configuration for debugging

  • One processor in processor socket 1

  • One DIMM in slot 3

  • One power supply

  • One HDD or M.2 (If OS installation is needed for debugging)

  • Four system fans (fan 1 to fan 4)

Environment

The server is supported in the following environment:
Note
This server is designed for standard data center environment and recommended to be placed in industrial data center.
  • Air temperature:

    • Operating:
      • ASHRAE class A2: 10–35°C (50–95°F); when the altitude exceeds 900 m (2953 ft), the maximum ambient temperature value decreases by 1°C (1.8°F) with every 300 m (984 ft) of altitude increase.

      • ASHRAE class A3: 5–40°C (41–104°F); when the altitude exceeds 900 m (2953 ft), the maximum ambient temperature value decreases by 1°C (1.8°F) with every 175 m (574 ft) of altitude increase.

      • ASHRAE class A4: 5–45°C (41–113°F); when the altitude exceeds 900 m (2953 ft), the maximum ambient temperature value decreases by 1°C (1.8°F) with every 125 m (410 ft) of altitude increase.

    • Server off: 5–45°C (41–113°F)

    • Shipping or storage: -40–60°C (-40–140°F)

  • Maximum altitude: 3050 m (10 000 ft)

  • Relative humidity (non-condensing):

    • Operating:
      • ASHRAE class A2: 8%–80%; maximum dew point: 21°C (70°F)

      • ASHRAE class A3: 8%–85%; maximum dew point: 24°C (75°F)

      • ASHRAE class A4: 8%–90%; maximum dew point: 24°C (75°F)

    • Shipping or storage: 8%–90%

  • Particulate contamination
    Attention
    Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.
Note
Your server complies with ASHRAE class A2 specifications. The server performance might be impacted when the operating temperature is outside the ASHRAE A2 specifications. Depending on the hardware configuration, some server models comply with ASHRAE class A3 and class A4 specifications. To comply with ASHRAE class A3 and class A4 specifications, the server models must meet the following hardware configuration requirements at the same time:
  • Two power supplies must be installed.

  • No system fan fails.

Important information about EU ecodesign requirements

To meet the EU ecodesign requirements for energy-related products (ErP) Lot 9, your server must meet the following requirements:
  • Minimum memory: 16 GB

  • For server configured with one processor, these processors are not supported: Intel Xeon 3104, 3106, 3204, 4108, 4109T, 4110, 4112, 5122, 5222, 8156, and 8256.