System board jumpers
The following illustration shows the jumpers on the system board of your server.
Jumper / Switch name | Jumper / Switch number | Jumper / Switch setting |
---|---|---|
1 TPM/TCM physical presence jumper | JP6 |
|
2 Clear CMOS jumper | JP3 |
|
3 SW6 switch block | JP8 |
Note For debug only. |
4 SW6 switch block | SW6 (including switches 1, 2, 3, 4, 5, 6, 7, and 8) | All the switches are in the Off position by default.
|
4 Power permission | SW6-7 | The default position is Off. Changing this switch to the On position enables Power On. |
4 Force XCC reset | SW6-4 | The default position is Off. Changing this switch to the On position reset the Lenovo XClarity Controller. |
4 Boot backup UEFI | SW6-5 | The default position is Off. Changing this switch to the On position forces the tower server to boot from the backup UEFI image. |
4 Force XCC update | SW6-3 | The default position is Off. Changing this switch to the On position force the Lenovo XClarity. |
- Before you move any jumpers, power off the server; then, disconnect all power cords and external cables. Do not open your server or attempt any repair before reading and understanding the following information:
- Any system-board switch or jumper block that is not shown in the illustrations in this document are reserved.