6 x 2.5'' SAS/SATA + 4 x 2.5'' AnyBay backplane (one processor)
Use this section to understand the AnyBay backplane cable routing for server model with ten 2.5-inch front drives and one processor.
Cable routing for 6 x 2.5'' SAS/SATA and 4 x 2.5'' AnyBay drives, and 1 x 16i SFF RAID adapter (Gen 3/Gen 4)
Figure 1. Cable routing for 6 x 2.5'' SAS/SATA and 4 x 2.5'' AnyBay drives, and 1 x 16i SFF RAID adapter (Gen 3/Gen 4)


From | To | Cable length |
---|---|---|
1 SAS 0 and SAS 1 connectors on backplane | 1
|
|
2 Power connector on backplane | 2 Power connector 2A connector on processor board | 480 mm |
3 NVMe 6-7 connector on backplane | 3 PCIe connector 4 on processor board | 250 mm |
4 SAS 2 connector on backplane | 4
| 900 mm |
5 NVMe 8-9 connector on backplane | 5 PCIe connector 3 on processor board | 350 mm |
Cable routing for 6 x 2.5'' SAS/SATA and 4 x 2.5'' AnyBay drives, and 1 x 16i CFF RAID adapter (Gen 4)
Figure 2. Cable routing for 6 x 2.5'' SAS/SATA and 4 x 2.5'' AnyBay drives, and 1 x 16i CFF RAID adapter (Gen 4)


From | To | Cable length |
---|---|---|
1 SAS 0 connector on backplane | 1 C0 connector on RAID adapter | 175 mm |
2 Input connector on RAID adapter | 2 PCIe connector 2 on processor board | 450 mm |
3 Power connector on backplane | 3 Power connector 2A on processor board | 480 mm |
4 SAS 1 connector on backplane | 4 C1 connector on RAID adapter | 150 mm |
5 NVME 6-7 connector on backplane | 5 PCIe connector 4 on processor board | 250 mm |
6 SAS 2 connector on backplane | 6 C2 connector on RAID adapter | 210 mm |
7 NVME 8-9 connector on backplane | 7 PCIe connector 3 on processor board | 350 mm |
8 Power connector on RAID adapter | 8 Power connector 13 and internal RAID power connector on processor board | 300/800 mm |