Aller au contenu principal

2.5-inch (6 SAS/SATA + 4 AnyBay)

ConfigurationRear BPStorage controller
Qty.TypeQty.Type
Config. 1    
Config. 21SFF 16i RAID/HBA
Config. 3  1CFF 16i RAID/HBA
Config. 412 x 2.5" SAS/SATA
Config. 512 x 2.5" SAS/SATA1CFF 16i RAID/HBA
En fonction de vos configurations de serveur, consultez l’une des sections suivantes pour obtenir des informations sur le cheminement des câbles.

Configuration 1 – 3:

Front BP: [6 x 2.5" SAS/SATA + 4 x 2.5" Anybay] BP

Config.Front BPSystem boardStorage controller
SFF 16i RAID/HBACFF 16i RAID/HBA
1NVMe 0-1PCIe 3  
NVMe 2–3PCIe 7  
SAS 0PCIe 2  
SAS 1PCIe 4  
SAS 2PCIe 5  
2NVMe 0–1

2 CPUs installed: PCIe 3

1 CPU installed: PCIe 1, PCIe 2

NVMe 2–3

2 CPUs installed: PCIe 7

1 CPU installed: PCIe 3

SAS 0, SAS 1

Gen 4: C 0

Gen 3: C 0, C 1

SAS 2

Gen 4: C 1

Gen 3: C 2

3NVMe 0–1PCIe 3  
NVMe 2–3PCIe 7  
SAS 0  C 0
SAS 1  C 1
SAS 2  C 2
 PCIe 8 MB

Exemple

Figure 1. Configuration 2 (2 CPU installed)
Cable routing for configuration 2

Configurations 4 – 5:

Front BP: [6 x 2.5" SAS/SATA + 4 x 2.5" Anybay] BP

Rear BP: 2 x 2.5'' SAS/SATA BP

Config.Front BPRear BPSystem boardStorage controller
CFF 16i RAID/HBA
4NVMe 0-1 PCIe 3 
NVMe 2–3 PCIe 7 
SAS 0 PCIe 2 
SAS 1 PCIe 4 
SAS 2SASPCIe 5 
5NVMe 0–1PCIe 3
NVMe 2–3PCIe 7
SAS 0C 0
SAS 1C 1
SAS 2C 2
SASC 3
PCIe 8MB

Exemple

Figure 2. Configuration 5
Cable routing for configuration 5