2.5-inch (6 SAS/SATA + 4 AnyBay)
Configuration | Rear BP | Storage controller | ||
Qty. | Type | Qty. | Type | |
Config. 1 | ||||
Config. 2 | 1 | SFF 16i RAID/HBA | ||
Config. 3 | 1 | CFF 16i RAID/HBA | ||
Config. 4 | 1 | 2 x 2.5" SAS/SATA | ||
Config. 5 | 1 | 2 x 2.5" SAS/SATA | 1 | CFF 16i RAID/HBA |
В зависимости от конфигураций сервера см. один из следующих разделов для получения сведения о прокладке кабелей.
Configuration 1 – 3:
Front BP: [6 x 2.5" SAS/SATA + 4 x 2.5" Anybay] BP
Config. | Front BP | System board | Storage controller | |
SFF 16i RAID/HBA | CFF 16i RAID/HBA | |||
1 | NVMe 0-1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS 0 | PCIe 2 | |||
SAS 1 | PCIe 4 | |||
SAS 2 | PCIe 5 | |||
2 | NVMe 0–1 | 2 CPUs installed: PCIe 3 1 CPU installed: PCIe 1, PCIe 2 | ||
NVMe 2–3 | 2 CPUs installed: PCIe 7 1 CPU installed: PCIe 3 | |||
SAS 0, SAS 1 | Gen 4: C 0 Gen 3: C 0, C 1 | |||
SAS 2 | Gen 4: C 1 Gen 3: C 2 | |||
3 | NVMe 0–1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS 0 | C 0 | |||
SAS 1 | C 1 | |||
SAS 2 | C 2 | |||
PCIe 8 | MB |
Пример
Рис. 1. Configuration 2 (2 CPU installed)
Configurations 4 – 5:
Front BP: [6 x 2.5" SAS/SATA + 4 x 2.5" Anybay] BP
Rear BP: 2 x 2.5'' SAS/SATA BP
Config. | Front BP | Rear BP | System board | Storage controller |
CFF 16i RAID/HBA | ||||
4 | NVMe 0-1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS 0 | PCIe 2 | |||
SAS 1 | PCIe 4 | |||
SAS 2 | SAS | PCIe 5 | ||
5 | NVMe 0–1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS 0 | C 0 | |||
SAS 1 | C 1 | |||
SAS 2 | C 2 | |||
SAS | C 3 | |||
PCIe 8 | MB |
Пример
Рис. 2. Configuration 5
Предоставить обратную связь