3.5 インチ (4 AnyBay)
| Configuration | Rear BP | Storage controller | ||
| Qty. | Type | Qty. | Type | |
| Config. 1 | ||||
| Config. 2 | 1 | SFF 8i RAID/HBA | ||
| Config. 3 | 1 | SFF 16i RAID(Tri-mode) | ||
| Config. 4 | 1 | 2 x 2.5" SAS/SATA | ||
| Config. 5 | 1 | 2 x 2.5" SAS/SATA | 1 | SFF 8i RAID/HBA |
| Config. 6 | 1 | 2 x 2.5" NVMe | ||
| Config. 7 | 1 | 2 x 2.5" NVMe | 1 | SFF 8i RAID/HBA |
サーバー構成に応じて、以下のいずれかのセクションを参照して、ケーブル配線情報を確認してください。
構成 1 – 3:
Front BP: 4 x 3.5'' AnyBay BP
| Config. | Front BP | System board | Storage controller | |
| SFF 8i RAID/HBA | SFF 16i RAID(Tri-mode) | |||
| 1 | NVMe 0–1 | PCIe 3 | ||
| NVMe 2–3 | PCIe 7 | |||
| SAS | PCIe 2 | |||
| 2 | NVMe 0–1 | PCIe 3 | ||
| NVMe 2–3 | PCIe 7 | |||
| SAS | Gen 4: C 0 Gen 3: C 0, C 1 | |||
| 3 | SAS | Gen 4: C 0 | ||
例
図 1. Configuration 2


構成 4 – 7:
Front BP: 4 x 3.5'' AnyBay BP
Rear BP: 2 x 2.5'' SAS/SATA BP
| Config. | Front BP | Rear BP | System board | Storage controller |
| SFF 8i RAID/HBA | ||||
| 4 | NVMe 0–1 | PCIe 3 | ||
| NVMe 2–3 | PCIe 7 | |||
| SAS | PCIe 2 | |||
| SAS | PCIe 5 | |||
| 5 | NVMe 0–1 | PCIe 3 | ||
| NVMe 2–3 | PCIe 7 | |||
| SAS | SAS | Gen 4: C 0 Gen 3: C 0, C 1 |
例
図 2. Configuration 5


Front BP: 4 x 3.5'' AnyBay BP
Rear BP: 2 x 2.5'' NVMe BP
| Config. | Front BP | Rear BP | System board | Storage controller |
| SFF 8i RAID/HBA | ||||
| 6 | NVMe 0–1 | PCIe 3 | ||
| NVMe 2–3 | PCIe 7 | |||
| SAS | PCIe 2 | |||
| NVMe 0, NVMe 1 | PCIe 6 | |||
| 7 | NVMe 0–1 | PCIe 3 | ||
| NVMe 2–3 | PCIe 7 | |||
| SAS | Gen 4: C 0 Gen 3: C 0, C 1 | |||
| NVMe 0, NVMe 1 | PCIe 6 |
例
図 3. Configuration 7


フィードバックを送る