3,5 Zoll (4 AnyBay)
Configuration | Rear BP | Storage controller | ||
Qty. | Type | Qty. | Type | |
Config. 1 | ||||
Config. 2 | 1 | SFF 8i RAID/HBA | ||
Config. 3 | 1 | SFF 16i RAID(Tri-mode) | ||
Config. 4 | 1 | 2 x 2.5" SAS/SATA | ||
Config. 5 | 1 | 2 x 2.5" SAS/SATA | 1 | SFF 8i RAID/HBA |
Config. 6 | 1 | 2 x 2.5" NVMe | ||
Config. 7 | 1 | 2 x 2.5" NVMe | 1 | SFF 8i RAID/HBA |
In den folgenden Abschnitten finden Sie die für Ihre Serverkonfiguration geltenden Informationen zur Kabelführung.
Konfiguration 1 – 3:
Front BP: 4 x 3.5'' AnyBay BP
Config. | Front BP | System board | Storage controller | |
SFF 8i RAID/HBA | SFF 16i RAID(Tri-mode) | |||
1 | NVMe 0–1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS | PCIe 2 | |||
2 | NVMe 0–1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS | Gen 4: C 0 Gen 3: C 0, C 1 | |||
3 | SAS | Gen 4: C 0 |
Beispiel
Abbildung 1. Configuration 2
Konfiguration 4 – 7:
Front BP: 4 x 3.5'' AnyBay BP
Rear BP: 2 x 2.5'' SAS/SATA BP
Config. | Front BP | Rear BP | System board | Storage controller |
SFF 8i RAID/HBA | ||||
4 | NVMe 0–1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS | PCIe 2 | |||
SAS | PCIe 5 | |||
5 | NVMe 0–1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS | SAS | Gen 4: C 0 Gen 3: C 0, C 1 |
Beispiel
Abbildung 2. Configuration 5
Front BP: 4 x 3.5'' AnyBay BP
Rear BP: 2 x 2.5'' NVMe BP
Config. | Front BP | Rear BP | System board | Storage controller |
SFF 8i RAID/HBA | ||||
6 | NVMe 0–1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS | PCIe 2 | |||
NVMe 0, NVMe 1 | PCIe 6 | |||
7 | NVMe 0–1 | PCIe 3 | ||
NVMe 2–3 | PCIe 7 | |||
SAS | Gen 4: C 0 Gen 3: C 0, C 1 | |||
NVMe 0, NVMe 1 | PCIe 6 |
Beispiel
Abbildung 3. Configuration 7
Feedback geben