Skip to main content

FQXSFIO0034J : PCIe Link Speed has degraded from [arg1] to [arg2] in physical bay number [arg3].

PCIe Link Speed has degraded from [arg1] to [arg2] in physical bay number [arg3].

Severity

Warning

User Action

Complete the following steps:

  1. Check the log for a separate error related to an associated PCIe NVME disk, and resolve that error.
  2. Check the Lenovo Support site for an applicable service bulletin or firmware update for the system or adapter that applies to this error.
  3. Check the system spec to make sure that the PCIe NVME disk, is installed in the compatible bay and a compatible cable is used. If not, performance of this device might be impacted.
  4. If the problem persists, collect Service Data logs and contact Lenovo Support.
    Note
    The solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.