Skip to main content

FQXSPPW0104J : Power redundancy lost with sufficient remaining power.

Power redundancy lost with sufficient remaining power.

This message is for the use case when Power redundancy lost with sufficient remaining power.

Severity

Warning

Alert Category

Warning - Redundant Power Supply

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0806

SNMP Trap ID

10

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. For CRPS Premium:
    1. Check the PSU LEDs:
    2. If IN and OUT LED are not lit, check the power cord and input voltage.
    3. If IN LED is green and DC LED is yellow or not lit, remove and then reinstall the power supply unit.
    4. If the problem persists, collect service data log.
    5. Contact Lenovo Support.
  2. For CRPS:
    1. Check the LED on the PSU:
    2. If PSU LED is yellow, check power cord and input voltage.
    3. If PSU LED is still yellow, remove and re-install power supply unit.
    4. If the problem persists, collect service data log.
    5. Contact Lenovo Support.