Skip to main content

FQXSPPW0110M : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted.

This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient Resources.

Severity​

Error

Alert Category​

Critical - Redundant Power Supply

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0810

SNMP Trap ID​

9

Automatically Notify Support​

No

User Action​

Complete the following steps until the problem is solved:

  1. Check if one of the power supplies is missing, failed, or not installed properly. If so, reinstall it.
  2. Check the maximum power supply rate and power capping policy. If any power supply does not meet the requirements, change the power supply or modify the power capping mechanism.
  3. Upgrade all system firmware and chassis firmware (if applicable) to the latest level.
    Note
    If the device is part of a cluster solution, verify that the latest level of code is supported by the cluster solution before the update.
  4. Collect service data log from the XCC WebGUI and contact Lenovo Support.