2.5-inch drive bay chassis

Use the parts list in this section to identify each of the components that are available for server models with 2.5-inch front drive bays.

For more information about ordering parts:
  1. Go to Lenovo Data Center Support and navigate to the support page for your server.

  2. Click Parts.

  3. Enter the serial number to view a listing of parts for your server.

It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.

Note
Depending on the model, your server might look slightly different from the illustration. Some parts are available only on some models.
Figure 1. Server components (2.5-inch drive bay chassis)
Server components (2.5-inch drive bay chassis)

The parts listed in the following table are identified as one of the following:
  • T1: Tier 1 customer replaceable unit (CRU). Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request with no service agreement, you will be charged for the installation.

  • T2: Tier 2 customer replaceable unit (CRU). You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.

  • F: Field replaceable unit (FRU). FRUs must be installed only by trained service technicians.

  • C: Consumable and Structural parts. Purchase and replacement of consumable and structural parts (components, such as a filler or bezel) is your responsibility. If Lenovo acquires or installs a structural component at your request, you will be charged for the service.

DescriptionTypeDescriptionType
1 Top coverT12 Rear wall bracketsT1
3 Power supply unitT14 Rear 8 x 2.5-inch drive cageT1
5 Rear 4 x 2.5-inch drive cageT16 7mm drive cage (1U)T1
7 7mm drive cage (2FH + 7mm)T18 7mm drive backplanesT2
9 7mm drive bay fillerC10 7mm driveT1
11 OCP moduleT112 PCIe adapterT1
13 Serial port moduleT114 System fanT1
15 System fan cageT116 RAID flash power moduleT1
17 Intrusion switchT118 CFF RAID adapter/expanderT2
19 Right rack latch with front I/O moduleT120 Standard right rack latchT1
21 Left rack latch with VGA and external diagnostics portsT122 Left rack latch with external diagnostics portT1
23 Left rack latch with VGA portT124 Standard left rack latchT1
25 ChassisF26 External diagnostics handsetT1
27 Front I/O module with integrated diagnostics panelT128 Integrated diagnostics panelT1
29 Front I/O module with front operator panelT130 Security bezelC
31 2.5-inch driveT132 2.5-inch drive fillers (1-bay, 4-bay, or 8-bay)C
33 Middle/Rear 4 x 2.5-inch drive backplaneT134 Front 24 x 2.5-inch expander backplaneT1
35 Rear 8 x 2.5-inch drive backplaneT136 Front 8 x 2.5-inch drive backplaneT1
37 CMOS battery (CR2032)C38 Memory moduleT1
39 ProcessorF40 Heat sinksF
41 GPU air baffle fillerC42 Add-on air baffle (for GPU air baffle)T1
43 GPU air baffleT144 Mylar for standard air baffle fillernoteC
45 Standard air baffle fillerC46 Standard air baffleT1
47 M.2 drive backplaneT148 M.2 driveT1
49 M.2 retainer clipT150 Direct water cooling moduleF
51 Cold plate coverC52 ManifoldsFRU
53 1FH riser cage for DWCMC54 3FH riser cage for DWCMC
55 Hose holderC56 Bleeder kitFRU
57 42U in-row hose kitFRU58 42U/48U in-rack connection hose (return side)FRU
59 48U in-rack connection hose (supply side)FRU60 42U in-rack connection hose (supply side)FRU
61 Middle drive cageT162 4LP riser 3/4 cageT1
63 Riser 3/4 cardT164 Riser 3 cageT1
65 Riser 1 or riser 2 cageT166 1U riser cageT1
67 Riser card (LP)T168 Riser 1 or riser 2 cardT1
69 Riser 3 cardT270 Firmware and RoT security moduleF
71 System I/O boardF72 MicroSD cardT1
73 Processor boardF74 Processor fillerC
75 2U cable wall bracketT176 Management NIC adapterT1
77 Rear OCP interposer cardT178 Front OCP interposer cardT1
79 Riser 5 cardT280 Front adapter cageT1
Note
The Mylar is needed only for configurations with DWCM and is pasted on the outside of the standard air baffle filler. For details, see Install the air baffle.