UC, dissipateur thermique et combinaisons de ventilateurs
Modèles : 8 x 3,5 pouces / 8 x 2,5 pouces / 16 x 2,5 pouces
CPU group | Config. | Heat sink | Fan |
---|---|---|---|
C/B |
| 1U Aluminium | Performance |
All other configurations | 1U Aluminium | Standard/Performance | |
A | Double-wide GPUs | 1U Aluminium | Performance |
| 2U Standard/Performance | Performance | |
All other configurations | 2U Standard/Performance | Standard/Performance | |
D/Z/X |
| 2U Performance | Performance |
All other configurations | 2U Performance | Standard/Performance |
Modèles : 24 x 2,5 pouces / 12 x 3,5 pouces
CPU group | Config. | Heat sink | Fan |
C/B/A |
| 2U Standard/Performance | Performance |
Mid bays | 1U Aluminium | Performance | |
All other configurations | 2U Standard/Performance | Standard/Performance | |
D/Z/X |
| 2U Performance | Performance |
All other configurations | 2U Performance | Standard/Performance |
Les ventilateurs standards sont compatibles avec toutes les conditions ci-après. Dans les autres cas, il convient d’utiliser des ventilateurs de performance.
Pas de GPU
Pas de Mellanox ConnectX-6 100 GbE/200 GbE avec AOC
Pas de Xilinx Alveo U25 FPGA
Pas de Xilinx Alveo U50 FPGA
Pas de Broadcom 57454 10GBASE-T à 4 ports OCP
Pas de 3DS RDIMM 256 Go
Pas de baies d’unité centrales ou de baies d’unité arrière
Les configurations suivantes requièrent six ventilateurs :
configurations à deux processeurs
configurations à processeur unique avec des disques intermédiaires, des disques arrière ou une carte mezzanine 3
Si un adaptateur Ethernet OCP 3.0 est installé, lorsque le système est mis hors tension mais encore branché sur le secteur, les ventilateurs 5 et 6 continuent de tourner à une vitesse nettement inférieure. Il s'agit de la conception système pour assurer le refroidissement approprié de l'adaptateur Ethernet OCP 3.0.