Skip to main content

FQXSPCA0017M : Sensor [SensorElementName] has transitioned to critical from a less severe state.

Sensor [SensorElementName] has transitioned to critical from a less severe state.

This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

Severity​

Error

Alert Category​

Critical - Temperature

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0522

SNMP Trap ID​

0

Automatically Notify Support​

No

User Action​

Complete the following steps:

  1. Check the event log of XClarity Controller for any fan or cooling-related issues or power-related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place,clean, and correctly installed.
  3. Make sure that the room temperature is within operating specifications.