FQXSFMA0023M : Error has occurred in NVDIMM flash. NVDIMM backup/restore may not operate correctly. [arg1]

Error has occurred in NVDIMM flash. NVDIMM backup/restore may not operate correctly. [arg1]

Parameters

[arg1] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"

Severity

Error

User Action

Complete the following steps:

  1. Reseat the affected NDIMM, and the DIMM in the adjacent slots if populated.
  2. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this memory error.
  3. If the problem persists, collect Service Data logs and contact Lenovo Support.
    Note
    The solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.