Environmental specifications
Summary of the environmental specifications of server. Depending on the model, some features might not be available, or some specifications might not apply.
Ambient temperature management
Ambient temperature management |
---|
Adjust ambient temperature when specific components are installed. Keep the ambient temperature to 30°C or lower when ThinkSystem NVIDIA BlueField-3 B3220 VPI QSFP112 2P 200G PCIe Gen5 x16 Adapter is installed in PCIe riser 1 (PCIe slot 9). |
Environment
Environment |
---|
ThinkSystem SR780a V3 complies with ASHRAE Class A2 specifications. System performance may be impacted when operating temperature is outside ASHRAE A2 specification.
Note The server is designed for standard data center environment and recommended to be placed in industrial data center. |
Water requirements
Water requirements |
---|
Note The water required to initially fill the system side cooling loop must be reasonably clean, bacteria-free water (<100 CFU/ml) such as de-mineralized water, reverse osmosis water, de-ionized water, or distilled water. The water must be filtered with an in-line 50 micron filter (approximately 288 mesh). The water must be treated with anti-biological and anti-corrosion measures. |