ThinkAgile SXM Series power cabling
The ThinkAgile SXM Series rack and components come cabled for power. This information is provided for your reference.
Power cabling for 25U rack
The following table shows the power cabling for the ThinkAgile SXM Series 25U rack models. These settings apply regardless of the number of server nodes that are installed. Power cabling for all ThinkAgile SXM Series 25U rack models is the same, regardless of the individual server components. See the specific model information for details about the hardware components. Note that the power cabling is not the same as the 42U rack models.
Source | Destination | Connection type | ||
---|---|---|---|---|
PDU | Port | Device | Port | |
PDU-4 | 12 | “TOR-1” switch | PSU-2 | C13/C14 |
PDU-4 | 11 | Hardware Lifecycle Host | PSU-2 | C13/C14 |
PDU-4 | 10 | not used | n/a | n/a |
PDU-4 | 9 | not used | n/a | n/a |
PDU-4 | 8 | not used | n/a | n/a |
PDU-4 | 7 | not used | n/a | n/a |
PDU-4 | 6 | not used | n/a | n/a |
PDU-4 | 5 | not used | n/a | n/a |
PDU-4 | 4 | Server node 8 | PSU-2 | C13/C14 |
PDU-4 | 3 | Server node 7 | PSU-2 | C13/C14 |
PDU-4 | 2 | Server node 6 | PSU-2 | C13/C14 |
PDU-4 | 1 | Server node 5 | PSU-2 | C13/C14 |
PDU-4 | MGMT | not used | n/a | n/a |
PDU-3 | 12 | “TOR-1” switch | PSU-1 | C13/C14 |
PDU-3 | 11 | Hardware Lifecycle Host | PSU-1 | C13/C14 |
PDU-3 | 10 | not used | n/a | n/a |
PDU-3 | 9 | not used | n/a | n/a |
PDU-3 | 8 | not used | n/a | n/a |
PDU-3 | 7 | not used | n/a | n/a |
PDU-3 | 6 | not used | n/a | n/a |
PDU-3 | 5 | not used | n/a | n/a |
PDU-3 | 4 | Server node 8 | PSU-1 | C13/C14 |
PDU-3 | 3 | Server node 7 | PSU-1 | C13/C14 |
PDU-3 | 2 | Server node 6 | PSU-1 | C13/C14 |
PDU-3 | 1 | Server node 5 | PSU-1 | C13/C14 |
PDU-3 | MGMT | not used | n/a | n/a |
PDU-2 | 12 | “TOR-2” switch | PSU-2 | C13/C14 |
PDU-2 | 11 | BMC switch (if present) | PSU-2 | C13/C14 |
PDU-2 | 10 | not used | n/a | n/a |
PDU-2 | 9 | not used | n/a | n/a |
PDU-2 | 8 | not used | n/a | n/a |
PDU-2 | 7 | not used | n/a | n/a |
PDU-2 | 6 | not used | n/a | n/a |
PDU-2 | 5 | not used | n/a | n/a |
PDU-2 | 4 | Server node 4 | PSU-2 | C13/C14 |
PDU-2 | 3 | Server node 3 | PSU-2 | C13/C14 |
PDU-2 | 2 | Server node 2 | PSU-2 | C13/C14 |
PDU-2 | 1 | Server node 1 | PSU-2 | C13/C14 |
PDU-2 | MGMT | not used | n/a | n/a |
PDU-1 | 12 | “TOR-2” switch | PSU-1 | C13/C14 |
PDU-1 | 11 | BMC switch (if present) | PSU-1 | C13/C14 |
PDU-1 | 10 | not used | n/a | n/a |
PDU-1 | 9 | not used | n/a | n/a |
PDU-1 | 8 | not used | n/a | n/a |
PDU-1 | 7 | not used | n/a | n/a |
PDU-1 | 6 | not used | n/a | n/a |
PDU-1 | 5 | not used | n/a | n/a |
PDU-1 | 4 | Server node 4 | PSU-1 | C13/C14 |
PDU-1 | 3 | Server node 3 | PSU-1 | C13/C14 |
PDU-1 | 2 | Server node 2 | PSU-1 | C13/C14 |
PDU-1 | 1 | Server node 1 | PSU-1 | C13/C14 |
PDU-1 | MGMT | not used | n/a | n/a |
Power cabling for 42U rack
The following table shows the power cabling for the ThinkAgile SXM Series 42U rack models. These settings apply regardless of the number of server nodes that are installed. Power cabling for all ThinkAgile SXM Series 42U rack models is the same, regardless of the individual server components. See the specific model information for details about the hardware components.
Source | Destination | Connection type | ||
---|---|---|---|---|
PDU | Port | Device | Port | |
PDU-4 | 12 | not used | n/a | n/a |
PDU-4 | 11 | not used | n/a | n/a |
PDU-4 | 10 | not used | n/a | n/a |
PDU-4 | 9 | not used | n/a | n/a |
PDU-4 | 8 | Server node 16 | PSU-2 | C13/C14 |
PDU-4 | 7 | Server node 15 | PSU-2 | C13/C14 |
PDU-4 | 6 | Server node 14 | PSU-2 | C13/C14 |
PDU-4 | 5 | Server node 13 | PSU-2 | C13/C14 |
PDU-4 | 4 | Server node 12 | PSU-2 | C13/C14 |
PDU-4 | 3 | Server node 11 | PSU-2 | C13/C14 |
PDU-4 | 2 | Server node 10 | PSU-2 | C13/C14 |
PDU-4 | 1 | Server node 9 | PSU-2 | C13/C14 |
PDU-4 | MGMT | not used | n/a | n/a |
PDU-3 | 12 | not used | n/a | n/a |
PDU-3 | 11 | not used | n/a | n/a |
PDU-3 | 10 | not used | n/a | n/a |
PDU-3 | 9 | not used | n/a | n/a |
PDU-3 | 8 | Server node 16 | PSU-2 | C13/C14 |
PDU-3 | 7 | Server node 15 | PSU-2 | C13/C14 |
PDU-3 | 6 | Server node 14 | PSU-2 | C13/C14 |
PDU-3 | 5 | Server node 13 | PSU-2 | C13/C14 |
PDU-3 | 4 | Server node 12 | PSU-1 | C13/C14 |
PDU-3 | 3 | Server node 11 | PSU-1 | C13/C14 |
PDU-3 | 2 | Server node 10 | PSU-1 | C13/C14 |
PDU-3 | 1 | Server node 9 | PSU-1 | C13/C14 |
PDU-3 | MGMT | not used | n/a | n/a |
PDU-2 | 12 | “TOR-2” switch | PSU-2 | C13/C14 |
PDU-2 | 11 | “TOR-1” switch | PSU-2 | C13/C14 |
PDU-2 | 10 | “BMC” switch (if present) | PSU-2 | C13/C14 |
PDU-2 | 9 | Hardware Lifecycle Host | PSU-2 | C13/C14 |
PDU-2 | 8 | Server node 8 | PSU-2 | C13/C14 |
PDU-2 | 7 | Server node 7 | PSU-2 | C13/C14 |
PDU-2 | 6 | Server node 6 | PSU-2 | C13/C14 |
PDU-2 | 5 | Server node 5 | PSU-2 | C13/C14 |
PDU-2 | 4 | Server node 4 | PSU-2 | C13/C14 |
PDU-2 | 3 | Server node 3 | PSU-2 | C13/C14 |
PDU-2 | 2 | Server node 2 | PSU-2 | C13/C14 |
PDU-2 | 1 | Server node 1 | PSU-2 | C13/C14 |
PDU-2 | MGMT | not used | n/a | n/a |
PDU-1 | 12 | “TOR-2” switch | PSU-1 | C13/C14 |
PDU-1 | 11 | “TOR-1” switch | PSU-1 | C13/C14 |
PDU-1 | 10 | “BMC” switch (if present) | PSU-1 | C13/C14 |
PDU-1 | 9 | Hardware Lifecycle Host | PSU-1 | C13/C14 |
PDU-1 | 8 | Server node 8 | PSU-1 | C13/C14 |
PDU-1 | 7 | Server node 7 | PSU-1 | C13/C14 |
PDU-1 | 6 | Server node 6 | PSU-1 | C13/C14 |
PDU-1 | 5 | Server node 5 | PSU-1 | C13/C14 |
PDU-1 | 4 | Server node 4 | PSU-1 | C13/C14 |
PDU-1 | 3 | Server node 3 | PSU-1 | C13/C14 |
PDU-1 | 2 | Server node 2 | PSU-1 | C13/C14 |
PDU-1 | 1 | Server node 1 | PSU-1 | C13/C14 |
PDU-1 | MGMT | not used | n/a | n/a |