The ThinkAgile SXN3000 product is precabled for the management network and data network. This information is provided for your reference.
The ThinkSystem NE2572 utilizes the dual-port Mellanox ConnectX-4 25GB HCA to enable 25 Gb Ethernet. The implementation is analogous to 10 Gb SFP+.
The following images show the
ThinkSystem NE2572 cabling connections for the
ThinkAgile HX appliances and enclosures in the
SXN3000:.
Figure 1. ThinkSystem NE2572 cabling for 1U and 2U appliances Table 1. ThinkSystem NE2572 Switch 1 cabling for 1U/2U appliances | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
1 | Management | | RackSwitch G8052 | 37 | 1.25m CAT6 Green Cable |
2 | 25 Gb NIC1 | 1–32 | ThinkAgile HX appliances | 1 | 3m SFP28 DAC Cable |
3 | Uplink | QSFP28 1, 2 | Customer switch | | Any 2 of the following:20m 100G QSFP28 Active Optical Cable 20m SFP+ to SFP+ Active Optical Cable 20m 25G SFP28 Active Optical Cable 20m 40G QSFP+ to QSFP+ Active Optical Cable
|
4 | VLAG | QSFP28 3 | ThinkSystem NE2572 switch 2 | QSFP28 5 | 1m Passive 100G QSFP28 DAC Cable |
QSFP28 4 | ThinkSystem NE2572 switch 2 | QSFP28 6 |
Table 2. ThinkSystem NE2572 Switch 2 cabling for 1U/2U appliances | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
5 | Management | | RackSwitch G8052 | 38 | 1.25m CAT6 Green Cable |
6 | 25 Gb NIC1 | 1–32 | ThinkAgile HX appliances | 2 | 3m SFP28 DAC Cable |
7 | 10 Gb DAC connection (initial setup only) | 48 | RackSwitch G8052 | | 1m Passive DAC SFP+ Cable |
8 | Uplink | QSFP28 1, 2 | Customer switch | | Any 2 of following:20m 100G QSFP28 Active Optical Cable 20m 20m SFP+ to SFP+ Active Optical Cable 25G SFP28 Active Optical Cable 20m 40G QSFP+ to QSFP+ Active Optical Cable
|
Figure 2. ThinkSystem NE2572 cabling for 2U4N enclosures Table 3. ThinkSystem NE2572 Switch 1 cabling for 2U4N enclosures | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
1 | Management | | RackSwitch G8052 | 37 | 1.25m CAT6 Green Cable |
2 | 25 Gb NIC1 | 1–32 | ThinkAgile HX enclosures | 1 | 3m SFP28 DAC Cable |
3 | Uplink | QSFP28 1 and 2 | Customer switch | | Any 2 of the following:20m 100G QSFP28 Active Optical Cable 20m SFP+ to SFP+ Active Optical Cable 20m 25G SFP28 Active Optical Cable 20m 40G QSFP+ to QSFP+ Active Optical Cable
|
4 | VLAG | QSFP28 3 | ThinkSystem NE2572 switch 2 | QSFP28 5 | 1m Passive 100G QSFP28 DAC Cable |
QSFP28 4 | ThinkSystem NE2572 switch 2 | QSFP28 6 |
Table 4. ThinkSystem NE2572 Switch 2 cabling for 2U4N enclosures | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
5 | Management | | RackSwitch G8052 | 38 | 1.25m CAT6 Green Cable |
6 | 25 Gb NIC1 | 1–32 | ThinkAgile HX enclosures | 2 | 3m SFP28 DAC Cable |
7 | 10 Gb DAC connection (initial setup only) | 48 | RackSwitch G8052 | | 1m Passive DAC SFP+ Cable |
8 | Uplink | QSFP28 1 and 2 | Customer switch | | Any 2 of following:20m 100G QSFP28 Active Optical Cable 20m SFP+ to SFP+ Active Optical Cable 20m 25G SFP28 Active Optical Cable 20m 40G QSFP+ to QSFP+ Active Optical Cable
|
The switch can be configured with 10Gb SFP+ or 10Gb Base-T. Different LOMs can be selected, but are limited to dual-port.
The following images show the
ThinkSystem NE1072T cabling connections for the
ThinkAgile HX appliances and enclosures in the
SXN3000.
Figure 3. ThinkSystem NE1072T cabling for 1U and 2U appliances Table 5. ThinkSystem NE1072T Switch 1 cabling for 1U/2U appliances | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
1 | Management | | RackSwitch G8052 | 37 | 1.25m CAT6 Green Cable |
2 | 10 Gb NIC1 | 1–32 | ThinkAgile HX appliances | 1 | 3m Green Cat5e Cable |
3 | Uplink (option 1) | Ethernet 45–48 | Customer switch | | 25m CAT6 Green Cable |
4, 5 | Uplink (option 2) | 40 Gb QSFP+ 1, 2, 5, 6 | Customer switch | | 20M 40Gb QSFP+ to QSFP+ Active Optical Cable |
6 | VLAG | 40 Gb QSFP 3 | ThinkSystem NE1072T switch 2 | QSFP 5 | 1m QSFP+-to-QSFP+ cable |
40 Gb QSFP 4 | ThinkSystem NE1072T switch 2 | QSFP 6 |
Table 6. ThinkSystem NE1072T Switch 2 cabling for 1U/2U appliances | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
7 | Management | | RackSwitch G8052 | 38 | 1.25m CAT6 Green Cable |
8 | 10 Gb NIC1 | 1–32 | ThinkAgile HX appliances | 2 | 3m Green Cat5e Cable |
9 | 1 Gb connection (initial setup only) | | RackSwitch G8052 | | 3m Green Cat5e Cable |
10 | Uplink (option 1) | Ethernet 45–48 | Customer switch | | 25m Cat6 Green Cable |
11 | Uplink (option 2) | 40 Gb QSFP+ 1–4 | Customer switch | | 20m 40Gb QSFP+ to QSFP+ Active Optical Cable |
Figure 4. ThinkSystem NE1072T cabling for 2U4N enclosures Table 7. ThinkSystem NE1072T Switch 1 cabling for 2U4N enclosures | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
1 | Management | | RackSwitch G8052 | 37 | 1.25m Cat6 Green Cable |
2 | 10 Gb NIC1 | 1–32 | ThinkAgile HX enclosures | 1 | 3m Green Cat5e Cable |
3 | Uplink (option 1) | Ethernet 45–48 | Customer switch | | 25m Cat6 Green Cable |
4, 5 | Uplink (option 2) | 40 Gb QSFP+ 1, 2, 5, 6 | Customer switch | | 20m 40Gb QSFP+ to QSFP+ Active Optical Cable |
6 | VLAG | 40 Gb QSFP 3 | ThinkSystem NE1072T switch 2 | QSFP 5 | 1m QSFP+-to-QSFP+ cable |
40 Gb QSFP 4 | ThinkSystem NE1072T switch 2 | QSFP 6 |
Table 8. ThinkSystem NE1072T Switch 2 cabling for 2U4N enclosures | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
7 | Management | | RackSwitch G8052 | 38 | 1.25m Cat6 Green Cable |
8 | 10 Gb NIC1 | 1–32 | ThinkAgile HX enclosures | 2 | 3m Green Cat5e Cable |
9 | 1 Gb connection (initial setup only) | | RackSwitch G8052 | | 3m Green Cat5e Cable |
10 | Uplink (option 1) | Ethernet 45–48 | Customer switch | | 25m Cat6 Green Cable |
11 | Uplink (option 2) | 40 Gb QSFP+ 1–4 | Customer switch | | 20m 40Gb QSFP+ to QSFP+ Active Optical Cable |
The switch can be configured with 10Gb SFP+ or 10Gb Base-T. Different LOMs can be selected, but are limited to dual-port.
The following images show the
RackSwitch G8272 cabling connections for the
ThinkAgile HX appliances and enclosures in the
SXN3000.
Figure 5. RackSwitch G8272 cabling for 1U and 2U appliances Table 9. RackSwitch G8272 Switch 1 cabling for 1U/2U appliances | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
1 | Management | | RackSwitch G8052 | 37 | 1.25m Cat6 Green Cable |
2 | 10 Gb NIC1 | 1–32 | ThinkAgile HX appliances | 1 | 3m Passive DAC Cable |
3 | Uplink (option 1) | 10 Gb SFP+ 45–48 | Customer switch | | 20m SFP+ to SFP+ Active Optical Cable |
4, 5 | Uplink (option 2) | 40 Gb QSFP+ 1, 2, 5, 6 | Customer switch | | 20m 40Gb QSFP+ to QSFP+ Active Optical Cable |
6 | VLAG | 40 Gb QSFP 3 | ThinkSystem NE1072T switch 2 | QSFP 5 | 1m QSFP+-to-QSFP+ cable |
40 Gb QSFP 4 | ThinkSystem NE1072T switch 2 | QSFP 6 |
Table 10. RackSwitch G8272 Switch 2 cabling for 1U/2U appliances | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
7 | Management | | RackSwitch G8052 | 38 | 1.25m Cat6 Green Cable |
8 | 10 Gb NIC1 | 1–32 | ThinkAgile HX appliances | 2 | 3m Passive DAC Cable |
9 | 10 Gb DAC connection (initial setup only) | | RackSwitch G8052 | | 1m Passive DAC SFP+ Cable |
10 | Uplink (option 1) | 10 Gb SFP+ 45–48 | Customer switch | | 20m SFP+ to SFP+ Active Optical Cable |
11 | Uplink (option 2) | 40 Gb QSFP+ 1–4 | Customer switch | | 20m 40Gb QSFP+ to QSFP+ Active Optical Cable |
Figure 6. RackSwitch G8272 cabling for 2U4N enclosures Table 11. RackSwitch G8272 Switch 1 cabling for 2U4N enclosures | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
1 | Management | | RackSwitch G8052 | 37 | 1.25m Cat6 Green Cable |
2 | 10 Gb NIC1 | 1–32 | ThinkAgile HX enclosures | 1 | 3m Passive DAC Cable |
3 | Uplink (option 1) | 10 Gb SFP+ 45–48 | Customer switch | | 20m SFP+ to SFP+ Active Optical Cable |
4, 5 | Uplink (option 2) | 40 Gb QSFP+ 1, 2, 5, 6 | Customer switch | | 20m 40Gb QSFP+ to QSFP+ Active Optical Cable |
6 | VLAG | 40 Gb QSFP 3 | ThinkSystem NE1072T switch 2 | QSFP 5 | 1m QSFP+-to-QSFP+ cable |
40 Gb QSFP 4 | ThinkSystem NE1072T switch 2 | QSFP 6 |
Table 12. RackSwitch G8272 Switch 2 cabling for 2U4N enclosures | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
7 | Management | | RackSwitch G8052 | 38 | 1.25m Cat6 Green Cable |
8 | 10 Gb NIC1 | 1–32 | ThinkAgile HX enclosures | 2 | 3m Passive DAC Cable |
9 | 10 Gb DAC connection (initial setup only) | | RackSwitch G8052 | | 1m Passive DAC SFP+ Cable |
10 | Uplink (option 1) | 10 Gb SFP+ 45–48 | Customer switch | | 20m SFP+ to SFP+ Active Optical Cable |
11 | Uplink (option 2) | 40 Gb QSFP+ 1–4 | Customer switch | | 20m 40Gb QSFP+ to QSFP+ Active Optical Cable |
ThinkAgile HX typically use only the 10Gb Ethernet connections. System management for ThinkAgile HX is handled in-band, so the 1Gb is typically only needed if systems require reimaging or out-of-band access.
The following images show the
RackSwitch G8052 cabling connections for the
ThinkAgile HX appliances and enclosures in the
SXN3000.
Figure 7. RackSwitch G8052 cabling for 1U and 2U appliances Table 13. RackSwitch G8052 cabling for 1U/2U appliances | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
1 | XCC | 1–32 | ThinkAgile HX appliances | 1 | 3m Green Cat5e Cable |
2 | Top-of-Rack switch management | 37, 38 | Top-of-Rack switch | | 1.25m Cat6 Green Cable |
3 | PDU management | 39, 40 | PDUs in Bays A and B | | 3m Green Cat5e Cable |
4 | 41, 42 | PDUs in Bays C and D | | 3m Green Cat5e Cable |
5 | 43, 44 | PDUs in Bays E and F | | 3m Green Cat5e Cable |
6 | Service/install | 45 | Service laptop | | 10m Cat6 Green Cable |
7 | Uplink (option 1) | 47, 48 | Customer switch (Ethernet) | | 25m Cat6 Green Cable |
8 | Uplink (option 2) | 49, 50 | Customer switch (SFP+) | | 20m SFP+ to SFP+ Active Optical Cable |
9 | Ethernet (initial setup option 1) | 46 | ThinkSystem NE1072T switch 2 | 44 | 3m Green Cat5e Cable |
10 | 10 Gb DAC connection (initial setup option 2) | 4 | RackSwitch G8272 switch 2 | 44 | 1m Passive DAC SFP+ Cable |
Figure 8. RackSwitch G8052 cabling for 2U4N enclosures Table 14. RackSwitch G8052 cabling for 2U4N enclosures | Source | Destination | Connection type |
---|
Usage | Port | Device | Port |
---|
1 | XCC | 1–32 | ThinkAgile HX enclosures | 1 | 3m Green Cat5e Cable |
2 | Top-of-Rack switch management | 37, 38 | Top-of-Rack switch | | 1.25m Cat6 Green Cable |
3 | PDU management | 39, 40 | PDUs in Bays A and B | | 3m Green Cat5e Cable |
4 | 41, 42 | PDUs in Bays C and D | | 3m Green Cat5e Cable |
5 | 43, 44 | PDUs in Bays E and F | | 3m Green Cat5e Cable |
6 | Service/install | 45 | Service laptop | | 10m Cat6 Green Cable |
7 | Uplink (option 1) | 47, 48 | Customer switch (Ethernet) | | 25m Cat6 Green Cable |
8 | Uplink (option 2) | 49, 50 | Customer switch (SFP+) | | 20m SFP+ to SFP+ Active Optical Cable |
9 | Ethernet (initial setup option 1) | 46 | ThinkSystem NE1072T switch 2 | 44 | 3m Green Cat5e Cable |
10 | 10 Gb DAC connection (initial setup option 2) | 4 | RackSwitch G8272 switch 2 | 44 | 1m Passive DAC SFP+ Cable |