Critical Events Reference
Critical events from DE Series arrays display certain defined fields in the alert and SNMP trap messages.
Recovery Guru
You can use the Recovery Guru to diagnose and recover from problems within your ThinkSystem System Manager.
Summary - Lists storage array problems.
Details - Shows information about the selected problem in the Summary pane.
Recovery Procedure - Lists the appropriate steps to resolve the selected problem in the Summary pane.
Storage array alert traps
MIB variable field | Description |
---|---|
Storage array name | Storage array user label. If the label contains non-ASCII characters, the resulting variable binding is populated with the fixed string "NonASCII Name." If the label is blank, the variable binding is populated with the fixed string "Unnamed." |
Event type | Event Code (4-digit hexadecimal) for the particular MEL event that prompted the trap. |
Event time | Timestamp of event in MM/DD/YYYY HH:MM:SS (24-hour clock) format. Note this is always controller/GMT time. |
Event description | Description of the specific MEL event that prompted the trap. |
Event component type | String representation of component type for the MEL vent that prompted the trap. Defaults to "Not Available" if component type cannot be identified. |
Event component location | This data is not populated by the embedded SNMP agent running on the controller at this time. |
Event severity | String representation of the severity of the MEL event that prompted the trap. Defaults to "Unknown" if severity cannot be identified. |
Event priority | String representation of the priority of the MEL event that prompted the trap. Defaults to "Unknown" if priority cannot be identified. |
Storage array WWID | 32-character printable ASCII representation of the 16-byte Storage Array World Wide Name. |
Chassis serial number | 32-character printable ASCII representation of the 16-byte Storage array World Wide Name. |
Critical event data
Critical event data from DE Series arrays is shown below:
MEL_EV_DRIVE_PFA - 0x1010
This event occurs when: The logged device generated a PFA condition.
Event Name - Drive PFA
Event description: Impending drive failure detected by drive
Event Group - Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_DRIVE_CDB
RecoveryFailureType - REC_IMPENDING_DRIVE_FAILURE_RISK_HIGH ( impendingDriveFailureHigh.html ), REC_IMPENDING_DRIVE_FAILURE_RISK_MED ( impendingDriveFailureMed.html )
MEL_EV_SYNTH_DRIVE_PFA - 0x101E
This event occurs when: The controller has detected that a drive failure is imminent.
Event Name - Synth Drv PFA
Event description: Impending drive failure detected by controller
Event Group - Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Error (0x1)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_DRIVE_SPFA_STATS
RecoveryFailureType - REC_IMPENDING_DRIVE_FAILURE_RISK_LOW ( impendingDriveFailureLow.html )
MEL_EV_PI_DRIVE_LOCKED_OUT - 0x1020
This event occurs when: An incompatible Protection Information drive has been discovered.
Event Name - PI Drive Locked Out
Event description: Data assurance drive has been locked out
Event Group - Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - State (0x5)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DRIVE_INCOMPATIBLE_PI_TYPE ( driveIncompatiblePIType.html )
MEL_EV_FC_LINK_ERROR_THRESHOLD_CRITICAL - 0x1207
This event occurs when: A Link Error count exceeds the threshold the first time.
Event Name - Link Error Threshold Critical
Event description: Fibre channel link errors - threshold exceeded
Event Group - Fibre Channel Source Driver
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_FC_SPEED_NEG_FAILURE - 0x1208
This event occurs when: A data rate negotiation fails.
Event Name - FC Speed Neg Failure
Event description: Data rate negotiation failed
Event Group - Fibre Channel Source Driver
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DEGRADE_CHANNEL - 0x1209
This event occurs when: A drive channel is set to degraded.
Event Name - Degrade Channel
Event description: Drive channel set to Degraded
Event Group - Fibre Channel Source Driver
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
MEL_DATA_DDS_RECORD
RecoveryFailureType - REC_CHANNEL_DEGRADED ( degradedDriveChannel.html )
MEL_EV_FC_SFP_FAILED - 0x120A
This event occurs when: The SFP on an XBB class controller has failed.
Event Name - SFP Failed
Event description: SFP failed
Event Group - Fibre Channel Source Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller SFP (0x2, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_FC_HOST_SFP_FAILED - 0x120D
This event occurs when: The host side SFP on an XBB class controller has failed.
Event Name - Host Side SFP Failed
Event description: Host-side SFP failed
Event Group - Fibre Channel Source Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller SFP (0x2, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_EXCESSIVE_REBOOTS_DETECTED - 0x1403
This event occurs when: This event is logged when the number of times a controller reboots reaches a certain threshold in a certain time window.
Event Name - Excessive Reboots Detected
Event description: Excessive reboots (exceptions) have occurred on the controller
Event Group - System
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_EXCESSIVE_REBOOTS_DETECTED
MEL_EV_DFC_ALT_LOOP_DIAG_FAIL - 0x150E
This event occurs when: A loop or minihub diagnostics detect that the controller is the bad device on the loop.
Event Name - Loop Diagnostic Failure
Event description: Controller loop-back diagnostics failed
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DFC_CHANNEL_MISWIRE - 0x150F
This event occurs when: Two channels are connected with one or more ESMs in between.
Event Name - Channel Miswire
Event description: Channel miswire
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DFC_ESM_MISWIRE - 0x1510
This event occurs when: Two IOMs (ESMs) of the same tray are seen on the same channel.
Event Name - ESM Miswire
Event description: IOM (ESM) miswire
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_ESM_MISWIRE ( esmMiswire.html )
MEL_EV_DFC_CHANNEL_FAILOVER - 0x1513
This event occurs when: A drive fails.
Event Name - Channel Failover
Event description: Individual drive - Degraded path
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
MEL_DATA_CHANNEL_LOCATION
RecoveryFailureType - REC_PATH_DEGRADED ( degradedDrivePath.html )
MEL_EV_DFC_HW_FAILED_CHANNEL - 0x1515
This event occurs when: A drive channel hardware fails.
Event Name - Drive Channel Hardware Failed
Event description: Drive Channel hardware failed
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
MEL_DATA_DDS_RECORD
RecoveryFailureType - N/A
MEL_EV_DFC_LSD_FAILURE - 0x151A
This event occurs when: A drive enclosure attached to a channel port is set to a link speed not supported by the SFP, resulting in a port bypass. Could also be Are is a faulty SFP, cable, or ESM.
Event Name - Link Speed Detection Failure
Event description: Optical link speed detection failure
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_LINK_SPEED_DETECTION_MISMATCH ( dataRateMismatch.html )
MEL_EV_DFC_CTL_MISWIRE - 0x151E
This event occurs when: This error is logged only for controllers with integrated drive channel ports. When two ESMs in the same drive tray are connected to different channels from the same controller. This error is reported for both channel ports involved in the miswire.
Event Name - Controller Miswire
Event description: Controller miswire for drive channel occurred
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel Port (0x2, 0x3)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DFC_MIXED_LOOP_TECHNOLOGY_MISWIRE - 0x1522
This event occurs when: Information not available.
Event Name - Drive Enclosure Type Miswire
Event description: Drive enclosure type miswire
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_MIXED_DRIVE_ENCLOSURE_MISWIRE ( mixedDriveTrayMiswire.html )
MEL_EV_DFC_TRUNK_INCOMPATIBLE_ESM - 0x1524
This event occurs when: The drive channel is trunk capable but an IOM (ESM) is determined to be trunk incompatible. This event is logged for each IOM (ESM) that is trunk incompatible.
Event Name - Trunk Incompatible ESM
Event description: Trunk incompatible IOM (ESM)
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_FIBRE_TRUNK_INCOMPATIBLE_ESM ( fcTrunkingIncompatibleEsm.html )
MEL_EV_DFC_FIBRE_TRUNK_MISWIRE - 0x1525
This event occurs when: Drive enclosures are trunk capable but are not cabled correctly for trunking or the cables themselves are missing. There should be one MEL event logged irrespective of the number of devices in miswire.
Event Name - Fibre Trunk Miswire
Event description: Fibre trunk miswire
Event Group - Fibre Channel-specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FIBRE_TRUNK_MISWIRE ( fcTrunkingMiswire.html )
MEL_EV_SAS_FRNT_END_MISWIRE - 0x1650
This event occurs when: Two ESMs or controllers, residing in the same tray, are cabled together.
Event Name - SAS Front End Miswire
Event description: SAS host channel miswire detected
Event Group - SAS-Specific Source Driver and Miscellaneous
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SAS_PORT_MISWIRED ( SASMiswire.html )
MEL_EV_SAS_PARTNER_INITIATOR_OVERFLOW - 0x1652
This event occurs when: A SAS source driver detects an initiator overflow condition resulting in the partner controller being unable to communicate with the SAS backend elements. This event is only logged on SAS-1 controllers (Mary Jane and Winterpark).
Event Name - Initiator Overflow
Event description: SAS source driver partner initiator overflow
Event Group - SAS-Specific Source Driver and Miscellaneous
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_DEVICE_NAME
RecoveryFailureType - N/A
MEL_EV_SAS_HOST_WIDE_PORT_DEGRADED - 0x1654
This event occurs when: One of the host port physical devices goes down from the optimal state.
Event Name - Host Wide Port Degraded
Event description: Host wide port is degraded
Event Group - SAS-Specific Source Driver and Miscellaneous
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - State (0x5)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_SAS_BACKEND_DISCOVERY_ERROR - 0x165A
This event occurs when: The event is logged when a connectivity error has been detected during the SAS backend discovery processing. The error means that there has been a loss of redundancy with the connectivity to trays and/or drives.
Event Name - SAS Backend Discovery Error
Event description: An error has been detected during SAS backend discovery processing
Event Group - SAS-Specific Source Driver and Miscellaneous
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DSAS_TOPOLOGY_MISWIRE - 0x1700
This event occurs when: A RAID controller detects an invalid SAS topology, such as an expander PHY with a table routing attribute attached to another expander PHY with a table routing attribute, a SAS loop, or multiple ports with the same SAS address.
Event Name - DSAS Topology Miswire
Event description: Invalid SAS topology detected
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SAS_PORT_MISWIRED ( SASMiswire.html ), REC_SAS_LOOP_MISWIRE ( SASLoopMiswire.html )
MEL_EV_DSAS_BK_END_HBA_MISWIRE - 0x1702
This event occurs when: A RAID controller detects a SAS adapter miswire.
Event Name - DSAS Back End HBA Miswire
Event description: SAS host adapter miswire detected
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SAS_PORT_MISWIRED ( SASMiswire.html ), REC_SAS_HOST_MISWIRE ( SASHostMiswire.html )
MEL_EV_DSAS_ESM_MISWIRE - 0x1704
This event occurs when: A RAID controller detects a SAS IOM (ESM) miswire.
Event Name - DSAS ESM Miswire
Event description: SAS IOM (ESM) miswire detected
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SAS_PORT_MISWIRED ( SASMiswire.html ), REC_SAS_CROSS_MISWIRE ( SASChannelMiswire.html )
MEL_EV_DSAS_WPORT_OPT_TO_DEG - 0x1706
This event occurs when: At least one of the phys that comprise a port is determined to be connected to an attached device, but the remaining port phys cannot connect to or communicate with an attached device.
Event Name - Optimal Wide Port Becomes Degraded
Event description: Optimal wide port becomes degraded
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_SAS_PORT_DEGRADED ( failedSASPort.html )
MEL_EV_DSAS_WPORT_DEG_TO_FAIL - 0x1707
This event occurs when: An attached device is determined to be present, but none of the PHYs that comprise the port attached to that device can connect to or communicate with the device.
Event Name - Degraded Wide Port Becomes Failed
Event description: Degraded wide port becomes failed
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_SAS_PORT_FAILED ( failedSASPort.html )
MEL_EV_DSAS_EXP_PORT_DEV_MISWIRE - 0x170A
This event occurs when: Information not available.
Event Name - DSAS Exp Port Dev Miswire
Event description: Drive expansion port miswire
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SAS_PORT_MISWIRED ( SASMiswire.html )
MEL_EV_DSAS_WPORT_OPT_TO_DEG_CTLR - 0x170F
This event occurs when: At least one of the phys that comprise a port is determined to be connected to an attached device, but the remaining port phys cannot connect to or communicate with an attached device.
Event Name - Controller Wide Port Has Gone To Degraded State
Event description: Controller wide port has gone to degraded state
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_SAS_PORT_DEGRADED ( failedSASPort.html )
MEL_EV_DSAS_WPORT_DEG_TO_FAIL_CTLR - 0x1710
This event occurs when: A device attached to the controller is determined to be present, but none of the PHYs that comprise the port attached to that device can connect to or communicate with the device.
Event Name - Controller Wide Port Has Gone To Failed State
Event description: Controller wide port has gone to failed state
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_SAS_PORT_FAILED ( failedSASPort.html )
MEL_EV_LOSS_EXT_REDUNDANCY - 0x171A
This event occurs when: A controller may have lost access to expansion trays.
Event Name - Loss of External Redundancy
Event description: A controller may have lost access to expansion trays
Event Group - SAS-Specific Destination Driver
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Channel Port (0x2, 0x3)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_LOSS_OF_EXTERNAL_REDUNDANCY ( noExtRedundancy.html )
MEL_EV_ISCSI_FAILED_HOST_CARD - 0x180A
This event occurs when: The firmware detects an iSCSI interface error. The optional data field of the MEL event includes information about the cause of the error, which, if Andrecht, Snowsnake, or Glencove HICS, includes (1) Uncorrectable ECC error, (2) The firmware cannot successfully restart the iSCSI interface, or (3) an iSCSI Controller EEPROM Error occurs. If Zion or Samoa HICS, the firmware cannot successfully restart the iSCSI interface.
Event Name - iSCSI Failed Host Card
Event description: Failed I/O host card; iSCSI interface error detected
Event Group - iSCSI-Specific
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Host Board (0x2, 0x5)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FAILED_HOST_IO_CARD ( failedHostCard.html )
MEL_EV_FAILED_HOST_INTERFACE_CARD - 0x1904
This event occurs when: The host interface card fails a loopback diagnostic test.
Event Name - Failed Host Interface Card
Event description: Failed host interface card
Event Group - Controller Field Replaceable HW
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Host I/O Card (0x2, 0xD)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_HOST_BOARD_FAULT ( hostCardFault.html )
MEL_EV_MISSING_DRIVE_LOCKDOWN - 0x1907
This event occurs when: A controller is locked down due to detecting enough missing drives that if left alone would result in failed volumes.
Event Name - Missing Drive Lockdown
Event description: Controller is locked down due to too many missing drives
Event Group - Controller Field Replaceable HW
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MISSING_DRIVE_LOCKDOWN ( missingDrivesLockdown.html )
MEL_EV_HIC_CONFIGURATION_OOC - 0x1908
This event occurs when: A controller has detected that the combination of host interface cards are out of compliance with limitations of the controller and/or the firmware.
Event Name - HIC Configuration OOC
Event description: A controller has detected that the combination of host interface cards are out of compliance with limitations of the controller and/or the firmware.
Event Group - Controller Field Replaceable HW
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_HIC_CONFIGURATION_OOC
MEL_EV_DATA_PARITY_MISMATCH - 0x200A
This event occurs when: A data/parity mismatch is detected during data scrubbing.
Event Name - Data Parity Mismatch
Event description: Data/parity mismatch on volume
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Volume (0x0, 0xD)
MEL_DATA_PARITY_READ_LBA
RecoveryFailureType - N/A
MEL_EV_MISCORRECTED_DATA - 0x202E
This event occurs when: An Unrecoverable Read Error is detected.
Event Name - Miscorrected Data
Event description: Read drive error during interrupted write
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_LBA_INFO
RecoveryFailureType - N/A
MEL_EV_DRIVE_FAIL_READ_ERROR_SCAN_CYCLE - 0x203B
This event occurs when: A drive is failed due to an unrecoverable read error detected during scan cycle.
Event Name - Drive Failure From Un-Recoverable Read Error
Event description: Drive failed due to un-recoverable read error during scan
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FAILED_DRIVE ( failedDrive.html )
MEL_EV_REDUN_GROUP_NOT_CONSISTENT - 0x2045
This event occurs when: As part of a reconfiguration operation, a redundancy group is determined to be inconsistent. After the reconfiguration operation completes, the data will be consistent but the data may be corrupt.
Event Name - Redundancy Group Not Consistent During Reconfiguration
Event description: Redundancy group not consistent during reconfiguration
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD)
MEL_DATA_PARITY_READ_LBA
RecoveryFailureType - REC_REDUNDANCY_GROUP_NOT_CONSISTENT_DURING_RECONFIG ( RedundancyGroupInconsistency.html )
MEL_EV_ISOLATION_REDUN_MISMATCH - 0x2046
This event occurs when: In RAID 6 environments, via media scan with redundancy check or when pre-read redundancy check is enabled. The event is logged when a drive can be isolated as causing corruption using P and Q parity of RAID 6. In this event data on disk is not altered as correction action without the potential of corruption is ambiguous.
Event Name - Isolation Redundancy Mismatch
Event description: Isolation of drive causing redundancy mismatch
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_REDUNDANCY_MISMATCH_DETECTED
RecoveryFailureType - N/A
MEL_EV_DIFFERENT_DATA_RETURNED_ON_RETRY - 0x2047
This event occurs when: A redundancy check results in retried reads and the drive returns different data on the retry.
Event Name - Different Data Returned On Retry
Event description: Different Data Returned On Read Retry
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_DIFFERENT_DATA_RETURNED_ON_RETRY
RecoveryFailureType - N/A
MEL_EV_DATA_ALTERED_TO_CORRECT_REDUN_MISMATCH - 0x2048
This event occurs when: Data is altered due to a detected inconsistency in redundancy. The data, which was within a redundancy group with multiple redundancy (e.g. RAID 6), was isolated, recovered, and rewritten to the drive.
Event Name - Data Altered to Correct Redundancy Mismatch
Event description: Data altered to correct redundancy mismatch
Event Group - VDD
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_REDUNDANCY_MISMATCH_DETECTED
RecoveryFailureType - N/A
MEL_EV_PI_SERVICE_MODE_ENTERED - 0x2069
This event occurs when: This event is logged when the controller has been rebooted into Service Mode because the controller has detected excessive Data Assurance errors.
Event Name - Data Assurance Service Mode Entered
Event description: Controller is in Service Mode due to excessive Data Assurance errors
Event Group - Protection Information
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_PI_ERROR_SERVICE_MODE
MEL_EV_PI_ANALYSIS_LOCKDOWN_MODE_ENTERED - 0x206A
This event occurs when: This event is logged when the controller has been rebooted into Analysis Lockdown Mode because the controller has detected excessive Data Assurance errors.
Event Name - Data Assurance Analysis Lockdown Mode Entered
Event description: Controller is in Analysis Lockdown Mode due to excessive Data Assurance errors
Event Group - Protection Information
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_PI_ERROR_LOCKDOWN
MEL_EV_CCM_HW_MISMATCH - 0x2109
This event occurs when: A write back cache could not be enabled due to different cache sizes of the controllers in the subsystem. ASC/ASCQ value of 0xA1/0x00 is also logged with this event.
Event Name - CCM Hardware Mismatch
Event description: Controller cache not enabled - cache sizes do not match
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_LBA_INFO
RecoveryFailureType - REC_CACHE_MEM_SIZE_MISMATCH ( cacheMismatch.html )
MEL_EV_CACHE_BATTERY_FAILURE - 0x210C
This event occurs when: A cache battery has failed. ASC/ASCQ of 0x0C/0x00 is also logged with this event.
Event Name - Cache Battery Failure
Event description: Controller cache battery failed
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
MEL_DATA_SMART_BATTERY
RecoveryFailureType - REC_FAILED_BATTERY ( failedBattery.html )
MEL_EV_CACHE_DATA_LOSS - 0x210E
This event occurs when: Logged by cache manager when cache blocks can't be successfully recovered. Companion to an ASC/ASCQ status of 0x0C/0x81.
Event Name - Cache Data Loss
Event description: Controller cache memory recovery failed after power cycle or reset
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_LBA_INFO
RecoveryFailureType - REC_CACHE_DATA_LOSS ( cache_failed_data_loss.html )
MEL_EV_CACHE_MEM_DIAG_FAIL - 0x2110
This event occurs when: A persistent RPA Memory Parity error is detected. A test of the cache memory (the data buffer on the controller) fails. The test is initiated with the startCacheMemoryDiagnostic_1 SYMbolAPI command. When the error occurs, the controller logs this event and locks down.
Event Name - Cache Memory Diagnostic Fail
Event description: Controller cache memory initialization failed
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_CACHE_BATTERY_WARN - 0x2113
This event occurs when: A cache battery is within the specified number of weeks of failing. The ASC/ASCQ value of 0x3F/0xD9 is also logged with this event.
Event Name - Cache Battery Warning
Event description: Controller cache battery nearing expiration
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Battery Pack (0x0, 0x9)
MEL_DATA_SMART_BATTERY
RecoveryFailureType - REC_BATTERY_NEAR_EXPIRATION ( batteryNearExpiration.html )
MEL_EV_OCB_SETTING_CONFLICT - 0x211B
This event occurs when: A conflict is detected between the NVSRAM setting and the presence of batteries.
Event Name - OCB Setting Conflict
Event description: Batteries present but NVSRAM file configured for no batteries
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_BATTERY_CONFIG_MISMATCH ( batterySettingsMismatch.html )
MEL_EV_UNSUPPORTED_CACHE_SIZE - 0x211E
This event occurs when: Controller is configured with an unsupported cache memory size.
Event Name - Unsupported Cache Size
Event description: Current cache size is unsupported
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_UNSUPPORTED_CACHE_MEMORY_SIZE ( unsupportedCacheMemSize.html )
MEL_EV_CACHE_BACKUP_INSUFFICIENT_CAPACITY - 0x211F
This event occurs when: The cache backup device is missing, leaving insufficient capacity to perform full cache backup.
Event Name - Insufficient Backup Device Capacity
Event description: Insufficient cache backup device capacity
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_CACHE_BACKUP_DEVICE_INSUFFICIENT_CAPACITY ( cacheBackupDevInsuffCapacity.html )
MEL_EV_INSUFFICIENT_MEMORY_FOR_CACHE_SIZE - 0x2120
This event occurs when: The controller has insufficient processor memory to support the configured cache.
Event Name - Insufficient Processor Memory For Cache
Event description: Insufficient processor memory for cache
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_PROC_MEM_TOO_SMALL_FOR_CACHE
MEL_EV_DEDICATED_MIRROR_CHANNEL_FAILED - 0x2124
This event occurs when: Information not available.
Event Name - Dedicated Mirror Channel Failed
Event description: Dedicated mirror channel failed
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DEDICATED_MIRROR_CHANNEL_FAILED ( failedDedicatedMirrorChannel.html )
MEL_EV_CACHE_BACKUP_PROTECTION_ERROR - 0x2125
This event occurs when: A data integrity check failed when the cache data was being restored from the backup device.
Event Name - Cache Backup Protection Error
Event description: Integrity check failed during cache restore
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_INCOMPLETE_CACHE_BACKUP - 0x2126
This event occurs when: The backup of the cache did not complete before the controller lost power -- input power and battery backup power.
Event Name - Incomplete Cache Backup
Event description: Backup of cache to persistent device did not complete
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_INC_BACKUP_REASON
RecoveryFailureType - N/A
MEL_EV_WB_CACHING_FORCIBLY_DISABLED - 0x212B
This event occurs when: Write-back caching is forcibly disabled beyond a threshold period of time for volumes that are configured to use the write caching capability.
Event Name - Write-back Caching Forcibly Disabled
Event description: Write-back caching forcibly disabled
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_VOLUMES_INFO
RecoveryFailureType - REC_WB_CACHING_FORCIBLY_DISABLED ( wBcacheDisabled.html )
MEL_EV_RCB_CACHE_DATA_LOSS - 0x212E
This event occurs when: Recovery control block information has been lost either while restoring from a backup device or some other reason.
Event Name - Recovery Control Block Cache Data Loss
Event description: Cached data may have been lost
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_CACHE_DATA_LOSS ( cache_failed_data_loss.html )
MEL_EV_CACHE_NOT_FLUSHED_ON_ONLY_CTLR - 0x2131
This event occurs when: Logged when the alternate controller is held in reset and this controller fails to flush dirty cache data on failed volume(s) possibly due to offlined drives. The controller should not be replaced to avoid loss of data.
Event Name - Dirty Cache Not Flushed On The Only Active Controller
Event description: Dirty cache not flushed on the only active controller
Event Group - Cache Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_CACHE_NOT_FLUSHED_ON_ONLY_CTLR
MEL_EV_DEVICE_FAIL - 0x222D
This event occurs when: A device is failed manually (via a SYMbolAPI command).
Event Name - Device Fail
Event description: Drive manually failed
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_CFG_DRV_TO_SMALL - 0x2249
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x8B indicating the controller set the drivestate to Drive Capacity is less than Minimum.
Event Name - CFG Drive Too Small
Event description: Physical drive replacement is too small
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_DRV_REPLACE
RecoveryFailureType - N/A
MEL_EV_WRONG_SECTOR_SIZE - 0x224A
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x8C indicating the controller set the drive state to Drive has wrong blocksize.
Event Name - Wrong Sector Size
Event description: Drive has wrong block size
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_WRONG_SECTOR_SIZE
RecoveryFailureType - REC_DRIVE_INCOMPATIBLE_SECTOR_SIZE ( sectorSizeIncompatible.html )
MEL_EV_DRV_FORMAT_FAILED - 0x224B
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x86 indicating the controller set the drive state to Failed Format failure.
Event Name - Drive Format Failed
Event description: Drive failed - initialization failure
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DRV_NO_RESPONSE - 0x224D
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x85 indicating the controller set the drive state to Failed No Response.
Event Name - Drive No Response
Event description: Drive failed - no response at start of day
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FAILED_DRIVE ( failedDrive.html )
MEL_EV_RECON_DRV_FAILED - 0x224E
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x82 indicating the controller set the drive state to Failed be it was unable to make the drive usable after replacement.
Event Name - Reconstruction Drive Failed
Event description: Drive failed - initialization/reconstruction failure
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_LUN_DOWN - 0x2250
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0xE0 indicating Logical Unit Failure.
Event Name - LUN Down
Event description: Volume failure
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FAILED_VOLUME ( failedVolume.html )
MEL_EV_CFG_READ_FAIL - 0x2251
This event occurs when: A configuration manager posts an UA/AEN of ASC/ASCQ = 0x3F/0x8E indicating that the drive failed due to a reconstruction failure at SOD.
Event Name - CFG Read Failure
Event description: Drive failed - reconstruction failure
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - State (0x5)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_FAIL_VDSK_DELAYED - 0x2252
This event occurs when: A specified device is failed during interrupted write processing. SK/ASC/ASCQ = 0x06/0x3F/0x98 will be offloaded for each failing device.
Event Name - Fail Vdisk Delayed
Event description: Drive marked offline during interrupted write
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_VOL_LABEL
RecoveryFailureType - N/A
MEL_EV_UNCERTIFIED_DRIVE - 0x2260
This event occurs when: An uncertified drive has been detected in the array.
Event Name - Uncertified Drive
Event description: Uncertified Drive Detected
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_UNCERTIFIED_DRIVE ( uncertifiedDrive.html )
MEL_EV_CFG_WRONG_DRIVE_TYPE - 0x2262
This event occurs when: A drive assigned to a volume group is failed, removed, and replaced with a drive that is not the same as the failed drive (for example, a Fibre Channel drive is replaced with a SATA drive).
Event Name - Configuration Wrong Drive Type
Event description: Failed drive replaced with wrong drive type
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_REPLACED_DRIVE_WRONG_TYPE ( incorrectDriveType.html )
MEL_EV_RECONFIGURATION_FAILED - 0x2266
This event occurs when: A drive fails during a reconfiguration operation causing the failure of all volumes in the volume group.
Event Name - Reconfiguration Failed
Event description: Volume modification operation failed
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume Group (0x0, 0xE), Disk Pool (0x3, 0x2)
MEL_SYMBOL_DATA_RETURNCODE
RecoveryFailureType - REC_FAILED_MODIFYING_VOLUME ( failedModifyingVolume.html )
MEL_EV_INCOMPAT_DRIVE_INVALID_CONFIG - 0x2267
This event occurs when: A drive transitions to incompatible due to a invalid volume group configuration.
Event Name - Incompatible Drive Due To Invalid Configuration
Event description: Incompatible drive due to invalid configuration on drive
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_ADOPTION_FAILED_RAID_LEVEL_UNSUPPORTED ( sodAdoptFailUnsupportedRAID.html ), REC_DB_ADOPTION_HARD_LIMIT_EXCEEDED ( sodAdoptFailHardLimitExceeded.html ), REC_DRIVE_INCOMPATIBLE_DOWNREV_DACSTORE ( downrevDacstoreIncomplete.html ), REC_DRIVE_INCOMPATIBLE_SECTOR_SIZE ( sectorSizeIncompatible.html ), REC_DRIVE_INCOMPATIBLE_UPREV_DACSTORE ( uprevDacstoreIncomplete.html ), REC_FOREIGN_DRIVE_INCONSISTENT ( pvgFrnDrvInconsConfig.html ), REC_FOREIGN_DRIVE_REFERS_TO_NATIVE_DRIVE ( pvgFrnDrvRefsNatDrv.html ), REC_REPLACED_INSUFFICIENT_DRIVE_CAPACITY ( replacedDriveWrongType.html ), REC_INCOMPATIBLE_FAILED_LEGACY_DRIVE ( pvgFailedLegacyDrive.html ), REC_MULTIPLE_CONFIG_DATABASES_DETECTED ( sodAdoptFailMultipleConfDBs.html ), REC_NATIVE_VG_FOREIGN_DRIVE_MUTUAL_REF ( pvgNatVgFrnDrvMutualRef.html ), REC_REPLACED_DRIVE_WRONG_TYPE ( incorrectDriveType.html ), REC_VG_CLONED ( pvgVgCloned.html ), REC_VG_DRIVE_PART_OF_MULTIPLE_VGS ( pvgMultVgsRefFrnDrv1.html ), REC_VG_HAS_DRIVE_PART_OF_MULTIPLE_VGS ( pvgMultVgsRefFrnDrv2.html ), REC_DRIVE_UNSUPPORTED_PROTOCOL_CONNECTION ( SATA_unsupported_protocol.html ), REC_DRIVE_INCOMPATIBLE_PI_TYPE ( driveIncompatiblePIType.html )
MEL_EV_FDE_LOCK_KEY_NEEDED - 0x226B
This event occurs when: A FDE lock key needed.
Event Name - FDE Lock Key Needed
Event description: Security (FDE) key needed
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_LOCK_KEY_NEEDED
RecoveryFailureType - REC_SECURITY_GET_KEY ( securityGetKey.html )
MEL_EV_CFG_DRIVE_FAILURE - 0x226C
This event occurs when: A drive failure has been detected.
Event Name - Drive Failure
Event description: Drive failure
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_DRIVE_FAILED
RecoveryFailureType - REC_FAILED_DRIVE ( failedDrive.html )
MEL_EV_DRIVE_IN_VG_OR_HOT_SPARE_REMOVED - 0x226D
This event occurs when: A drive that was assigned to a volume group or a hot spare drive that is in use has been removed.
Event Name - Drive In Volume Group Or Hot Spare In Use Removed
Event description: Assigned drive or hot spare-in use drive removed
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_HOTSPARE_DRIVE_MISSING ( missingHotSpare.html )
MEL_EV_SSD_AT_END_OF_LIFE - 0x226E
This event occurs when: It is recommended that the customer schedule replacing the SSD immediately or risk having the drive fail.
Event Name - SSD At End Of Life
Event description: Solid state disk drive at end of life
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SSD_AT_END_OF_LIFE ( ssdEndOfLife.html )
MEL_EV_DRIVE_UNSUPPORTED_CAPACITY - 0x2271
This event occurs when: The controller firmware detects a drive that has a capacity which is unsupported.
Event Name - Physical Drive Has Unsupported Capacity
Event description: Physical drive has unsupported capacity
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DRIVE_UNSUPPORTED_CAPACITY ( driveUnsupportedDriveCap.html )
MEL_EV_HOT_SPARE_IN_USE - 0x2273
This event occurs when: Information not available.
Event Name - Hot Spare In Use
Event description: Hot spare in use
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_VOLUME_HOT_SPARE_IN_USE ( volumeHotSpareInUse.html )
MEL_EV_VOLUME_GROUP_MISSING - 0x2274
This event occurs when: A volume group has gone to the missing state because all drives from the group have been removed.
Event Name - Volume Group Missing
Event description: Component is missing
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume Group (0x0, 0xE), Disk Pool (0x3, 0x2)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_VOLUME_GROUP_MISSING ( missingVGorDP.html )
MEL_EV_VOLUME_GROUP_INCOMPLETE - 0x2275
This event occurs when: A volume group becomes incomplete because one or more drives in the group have been removed.
Event Name - Volume Group Incomplete
Event description: Component incomplete
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume Group (0x0, 0xE), Disk Pool (0x3, 0x2)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_VOLUME_GROUP_INCOMPLETE ( incompleteVGorDP.html )
MEL_EV_DRIVE_UNSUP_INTERPOSER_FW_VER - 0x2276
This event occurs when: The firmware version in an interposer is incompatible with the drive behind the interposer. New interposer firmware is necessary.
Event Name - Interposer FW Version Unsupported
Event description: Interposer FW version unsupported
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DRIVE_UNSUPPORTED_INTERPOSER_FW_VERSION ( driveUnsupportedInterposerFWVersion.html )
MEL_EV_INCOMPATIBLE_ALIGNMENT_FOR_EMULATION_DRIVE - 0x2278
This event occurs when: Locking out an emulation drive that has a non-zero lowest aligned LBA. An emulation drive is one in which the logical and physical block sizes are not identical and therefore emulates the logical block size.
Event Name - Incompatible Alignment for Emulation Drive
Event description: Incompatible alignment for emulation drive
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_NON_ZERO_LOWEST_ALIGNED_LBA
RecoveryFailureType - REC_DRIVE_INCOMPATIBLE_ALIGNMENT_FOR_EMULATION_DRIVE ( incompatibleDriveAlignment.html )
MEL_EV_COPY_THEN_FAIL_NO_SPARE - 0x227C
This event occurs when: The controller detects an impending drive failure but is unable to trigger an automatic drive copy operation because there is not an eligible copy destination available.
Event Name - Copy Then Fail No Spare
Event description: Waiting for eligible copy destination to start drive copy
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_DRIVE_COPY_INFORMATION
RecoveryFailureType - REC_COPY_THEN_FAIL_WAITING_ON_HOT_SPARE ( impendingDriveFailurePending.html )
MEL_EV_DRIVE_PFA2 - 0x2285
This event occurs when: This event is logged when a PFA condition has been detected but an automatic drive copy operation will not be initiated because of the configuration settings or current volume state.
Event Name - Drive PFA 2
Event description: Impending drive failure detected by drive
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_IMPENDING_DRIVE_FAILURE_RISK_HIGH ( impendingDriveFailureHigh.html ), REC_IMPENDING_DRIVE_FAILURE_RISK_MED ( impendingDriveFailureMed.html )
MEL_EV_CFG_NTP_RES - 0x2287
This event occurs when: The controller was unable to resolve an IP address for the given domain name of the NTP server using the administered primary or secondary DNS.
Event Name - Primary/Secondary NTP Server Domain Name Resolution Failure
Event description: A NTP domain server name is either invalid or the configured primary or secondary DNS servers are unreachable
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_NET_NTP_RESOLUTION_FAIL ( UnableToResolveNTPAddress.html )
MEL_EV_CFG_NTP_UNREACH - 0x2288
This event occurs when: The controller was unable to reach an NTP server's resolved or configured IP address.
Event Name - Primary/Secondary NTP Server Unreachable
Event description: Either the NTP server's resolved or configured IP address is wrong or the IP address is unavailable via the attached network
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_NET_NTP_QUERY_FAIL ( ntpQueryFailed.html )
MEL_EV_CFG_NTP_SERVICE_UNAVAIL - 0x2289
This event occurs when: All SNTP queries to the configured Primary and Secondary NTP Servers have failed.
Event Name - NTP Service Unavailable
Event description: The DNS/NTP configuration on this controller is either incorrect or all the NTP servers are unreachable over the network
Event Group - Configuration Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_NET_NTP_SERVICE_UNAVAILABLE ( ntpServiceUnavailable.html )
MEL_EV_SBB_VALIDATION_FAIL_FOR_POWER_SUPPLY - 0x2302
This event occurs when: A power supply fails the validation for Storage Bridge Bay.
Event Name - SBB Validation Failure For Power Supply
Event description: SBB validation failure for power supply
Event Group - SBB Validation
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Power Supply (0x0, 0x2)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_INVALID_POWER_SUPPLY ( invalidPowerSupply.html )
MEL_EV_SBB_MISMATCHED_ENCL_EEPROM_CONTENTS - 0x2303
This event occurs when: The contents of the EEPROMs on the midplanes are not matched.
Event Name - Mismatched Midplane EEPROM Contents
Event description: Mismatched midplane EEPROM contents
Event Group - SBB Validation
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
MEL_DATA_TRAY_ID
RecoveryFailureType - REC_MISMATCHED_MIDPLANE_EEPROMS ( mismatched_midplane_eeproms.html )
MEL_EV_SBB_TWO_WIRE_INTERFACE_BUS_FAILURE - 0x2304
This event occurs when: A failure is detected on the two wire interface bus.
Event Name - Two Wire Interface Bus Failure
Event description: Two wire interface bus failure
Event Group - SBB Validation
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
MEL_DATA_TRAY_ID
RecoveryFailureType - REC_FAILED_I2C_BUS ( failed_i2c_bus.html )
MEL_EV_SBB_VPD_EEPROM_CORRUPTION - 0x2305
This event occurs when: VPD data in the Storage Bridge Bay EEPROM is corrupted.
Event Name - VPD EEPROM Corruption
Event description: VPD EEPROM corruption
Event Group - SBB Validation
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
MEL_DATA_TRAY_ID
RecoveryFailureType - REC_CORRUPT_VPD_EEPROM ( corrupt_vpd_eeprom.html )
MEL_EV_CONTROLLER - 0x2500
This event occurs when: A controller is removed from an array configured to use dual controllers.
Event Name - Controller Removed
Event description: Controller removed
Event Group - Hot Swap
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_REMOVED_CONTROLLER ( removedCtrl.html )
MEL_EV_ACS_ERROR - 0x2602
This event occurs when: An auto code synchronization failed.
Event Name - ACS Error
Event description: Automatic controller firmware synchronization failed
Event Group - Start of Day
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_PERSIST_MPE - 0x2604
This event occurs when: A SOD detects that the persistent memory parity error state has been set. RPA memory has reported a persistent error, this generally results in a lock-down.
Event Name - Persistent Memory Parity Error
Event description: Persistent controller memory parity error
Event Group - Start of Day
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_SOD_FDE_INCONSISTENT_ARRAY_LOCK_KEY - 0x2607
This event occurs when: An inconsistent array lock key situation is detected.
Event Name - FDE Inconsistent Array Lock Key
Event description: Inconsistent security (FDE) storage array lock key
Event Group - Start of Day
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SECURITY_KEY_INCONSISTENT ( fdeInconsistentSecurityKey.html )
MEL_EV_MULTIPLE_MISMATCHED_KEY_IDS - 0x2705
This event occurs when: Multiple mismatched drive lock key ids are detected by the firmware.
Event Name - Multiple Mismatched Key Ids Found
Event description: Multiple mismatched key ids found
Event Group - Start of Day
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MULTIPLE_MISMATCHED_KEY_IDS_FOUND ( multiMismatchKeyIDs.html )
MEL_EV_ON_BATTERY - 0x2801
This event occurs when: A UPS battery starts to supply power to the subsystem.
Event Name - On Battery
Event description: Storage array running on UPS battery
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_UPS_ON_BATTERY ( lostACPower.html )
MEL_EV_UPS_BATTERY_2MIN - 0x2803
This event occurs when: A UPS battery has transitioned and given the 2 minute warning. The UPS has signaled that it has 2 minutes of power left before failing. The controllers will flush any dirty data in their caches and turn off data caching.
Event Name - UPS Battery 2 Minute Warning
Event description: UPS battery - two minutes to failure
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_LINE_MISSING - 0x280A
This event occurs when: An expected subsystem line is removed.
Event Name - Line Missing
Event description: Controller tray component removed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_REMOVED_SUPPORT_CRU ( removedSupportCRU.html )
MEL_EV_LINE_FAILED - 0x280B
This event occurs when: A subsystem line has transitioned to the Failed state.
Event Name - Line Failed
Event description: Controller tray component failed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_FAILED_ICC_CRU ( failedInterconnectCRU.html ), REC_SUPPORT_CRU_NOINPUT ( supportCRUNoInput.html )
MEL_EV_ENCL_FAIL - 0x280D
This event occurs when: An enclosure has transitioned to the Failed state.
Event Name - Enclosure Fail
Event description: Drive tray component failed or removed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_FAN_UNKNOWN_STAT ( unknownCompStatus.html ), REC_REMOVED_ESM ( removedEsm.html ), REC_SUPPORT_CRU_NOINPUT ( supportCRUNoInput.html )
MEL_EV_ENCL_ID_CONFLICT - 0x2816
This event occurs when: A controller detects duplicate drive tray IDs in the subsystem.
Event Name - Enclosure ID Conflict
Event description: Tray ID conflict - duplicate IDs across drive trays
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_TRAYID_CONFLICT ( trayIdConflict.html )
MEL_EV_TEMP_SENSOR_WARNING - 0x281B
This event occurs when: A controller detects that a temperature sensor has transitioned to a warning status.
Event Name - Temperature Sensor Warning
Event description: Nominal temperature exceeded
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_NOMINAL_TEMP_EXCEEDED ( nominalTempExceeded.html )
MEL_EV_TEMP_SENSOR_FAIL - 0x281C
This event occurs when: A controller detects that a temperature sensor has transitioned to a failed status.
Event Name - Temperature Sensor Failed
Event description: Maximum temperature exceeded
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_MAX_TEMP_EXCEEDED ( maxTempExceeded.html )
MEL_EV_TEMP_SENSOR_MISSING - 0x281D
This event occurs when: A controller detects that a temperature sensor is missing. This event is logged in the temp sensor is missing which means an SES in an enclosure is missing. The user should check the enclosure to make sure both SES components are installed. A different event is A temp sensor is present but failed.
Event Name - Temperature Sensor Missing
Event description: Temperature sensor removed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_REMOVED_TEMP_SENSOR ( removedSupportCRU.html )
MEL_EV_ESM_VERSION_MISMATCH - 0x281E
This event occurs when: A controller detects that two IOMs (ESMs) do not have the same version of firmware running.
Event Name - ESM Version Mismatch
Event description: IOM (ESM) firmware mismatch
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_ESM_CODE_VERSION_MISMATCH ( trayCodeMismatch.html )
MEL_EV_BYPASS_GENERIC - 0x2823
This event occurs when: A drive is bypassed on both ports.
Event Name - Bypass Generic
Event description: Drive by-passed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_DRIVE_BYPASSED_CAUSE_UNKNOWN ( bypassedDrive.html )
MEL_EV_CONT_REDUNDANCY_LOSS - 0x2829
This event occurs when: An array determines that one controller is in a failed mode.
Event Name - Cont Redundancy Loss
Event description: Controller redundancy lost
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_TRAY_REDUNDANCY_LOSS - 0x282B
This event occurs when: A drive tray path fails.
Event Name - Tray Redundancy Loss
Event description: Drive tray path redundancy lost
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_LOST_REDUNDANCY_TRAY ( noRedundancyTray.html )
MEL_EV_DRIVE_REDUNDANCY_LOSS - 0x282D
This event occurs when: An array determines that a loss of drive path redundancy is a persistent condition.
Event Name - Drive Redundancy Loss
Event description: Drive path redundancy lost
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_DRIVE_BYPASSED_SINGLE_PORT ( bypassedDrive.html ), REC_LOST_REDUNDANCY_DRIVE ( noRedundancyDrive.html )
MEL_EV_UNSUPPORTED_LHA_SATA_ESM - 0x282F
This event occurs when: A firmware download to an IOM (ESM) fails because the IOM (ESM) firmware is not compatible with the version of controller firmware on the storage array.
Event Name - Unsupported LHA SATA ESM Detected
Event description: Incompatible version of IOM (ESM) firmware detected
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_ESM_HARDWARE_MISMATCH ( ESMHwMismatch.html )
MEL_EV_MIXED_DRIVE_TYPES_NOT_ALLOWED - 0x2830
This event occurs when: Logged for two reasons: (1) when mixed drive types are not supported and (2) when firmware determines that a mixture of physical drive types is present, Mixed Drive Types is configured as a premium feature, and MDT has not been enabled..
Event Name - Mixed Drive Types Not Allowed
Event description: Mixed drive types out of compliance
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MISMATCHED_DRIVE_TYPE ( mixedDrivesNotSupported.html )
MEL_EV_UNCERTIFIED_ESM - 0x2831
This event occurs when: An uncertified IOM (ESM) is discovered in a drive enclosure.
Event Name - Uncertified ESM
Event description: Uncertified IOM (ESM) detected
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_UNCERTIFIED_ESM ( uncertifiedESM.html )
MEL_EV_DRIVE_TRAY_LOCKOUT - 0x2832
This event occurs when: Both ESMs in the tray are uncertified, or there is only one ESM in the tray, and it is uncertified.
Event Name - Drive Tray Lockout
Event description: Uncertified drive tray detected
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_UNSUPPORTED_TRAY ( unsupportedDriveTray.html )
MEL_EV_CONT_ID_MISMATCH - 0x2833
This event occurs when: Either the base controller or the host interface card is found to be different between the primary and the alternate controller in a storage array.
Event Name - Mismatched Controller Types
Event description: Controller host interface card ID mismatch
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_CTL_MISMATCH ( ctrlMismatch.html )
MEL_EV_DRIVE_TRAYS_NOT_GROUPED_TOGETHER - 0x2835
This event occurs when: A storage array configuration requires drive trays to be sequentially cabled together, but they are not.
Event Name - Drive Trays Not Grouped Together
Event description: Drive trays not cabled correctly
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DRIVE_TRAYS_NOT_GROUPED_TOGETHER ( driveTrayCluster.html )
MEL_EV_DISCRETE_LINE_FAIL - 0x2836
This event occurs when: A discrete line test has failed, due to either a fault Controller or a faulty Interconnect Module.
Event Name - Discrete Line Failure
Event description: Discrete lines diagnostic failure
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_I2C_VALUE
RecoveryFailureType - REC_FAILED_DISCRETE_LINE ( discreteLineFailed.html )
MEL_EV_ICC_REMOVED - 0x2838
This event occurs when: An interconnect or battery canister is removed from the controller enclosure.
Event Name - Interconnect CRU Removed
Event description: Interconnect/battery canister removed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Interconnect-battery canister pack (0x2, 0x0)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_REMOVED_ICC_CRU ( removedInterconnectCRU.html )
MEL_EV_POWER_SUPPLY_FAIL - 0x283B
This event occurs when: A power supply fails.
Event Name - Power Supply Failure
Event description: Power supply failed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Power Supply (0x0, 0x2)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_FAILED_POWER_SUPPLY ( failedPowerSupply.html )
MEL_EV_CONT_SUBMODEL_MISMATCH - 0x2841
This event occurs when: An alternate controller has performed a self-lockdown due to an unsupported or mismatched sub-model identifier.
Event Name - Controller Submodel Mismatch
Event description: Controller submodel mismatch
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SUBMODEL_MISMATCH ( ctrlMismatch.html )
MEL_EV_ESM_TYPE_MISMATCH - 0x2849
This event occurs when: A controller detects an IOM (ESM) hardware mismatch in an enclosure in the storage array.
Event Name - ESM Type Mismatch
Event description: IOM (ESM) Hardware mismatch
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Tray Component (ESM, GBIC/SFP, Power Supply, or Fan) (0x0, 0x7)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_ESM_HARDWARE_MISMATCH ( ESMHwMismatch.html )
MEL_EV_LINK_SPEED_SWITCH_CHANGE - 0x284B
This event occurs when: A controller detects that an ESM hardware mismatch condition has been cleared.
Event Name - Link Speed Switch Change
Event description: Link Speed (data rate) switch position has changed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Channel (0x0, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_REDUNDANT_PS_REQUIRED - 0x284E
This event occurs when: A controller discovers a fan-only CRU in an enclosure that requires, for redundancy reasons, the power supply/fan combination CRU. This event will only be logged once when the condition occurs.
Event Name - Redundant Power Supply Required
Event description: Redundant power-fan canisters required - only one power-fan canister detected
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Power Supply (0x0, 0x2)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_REDUNDANT_PS_REQUIRED ( noRedundancyPowerFanPS.html )
MEL_EV_INVALID_ENCLOSURE_SETTING - 0x284F
This event occurs when: Needed.
Event Name - Invalid Enclosure Setting
Event description: Misconfigured tray
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_ENCLOSURE_MISCONFIGURED ( misconfiguredTray.html )
MEL_EV_FACTORY_DEFAULT_MISMATCH - 0x2852
This event occurs when: Two IOMs (ESMs) in an enclosure report different factory default VPD data, and the automated correction of this condition is unsuccessful.
Event Name - Factory Def Mismatch
Event description: IOM (ESM) configuration settings version mismatch
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
MEL_DATA_EDL_MEL_SWAPPED_B
RecoveryFailureType - REC_ESM_FACTORY_DEFAULTS_MISMATCH ( esmConfigSettingsMismatch.html )
MEL_EV_ESM_DRIVE_BYPASS - 0x2854
This event occurs when: A Fibre Channel drive port is bypassed by an ESM because the error thresholds have been exceeded.
Event Name - ESM Drv Bypass
Event description: Drive port bypassed - Error thresholds exceeded
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
MEL_DATA_DRIVE_FAULT
RecoveryFailureType - REC_DRIVE_BYPASSED_SINGLE_PORT ( bypassedDrive.html )
MEL_EV_CONT_ID_READ_FAILURE - 0x2855
This event occurs when: An alternate controller board ID cannot be read.
Event Name - Alternate Board Controller ID Cannot Be Read
Event description: Controller cannot read alternate controller board ID
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_ALT_CTLR_BOARD_ID_UNREADABLE ( ctrlNoIdentifier.html )
MEL_EV_DRAWER_FAILED - 0x2856
This event occurs when: A drawer has failed and is inoperable. The drives in this drawer are not accessible.
Event Name - Drawer Failed
Event description: Drawer failed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drawer (0x3, 0x0)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_DRAWER_FAILED ( failedDrawer.html )
MEL_EV_DRAWER_OPEN - 0x2857
This event occurs when: A drawer has been opened or removed.
Event Name - Drawer Open Or Removed
Event description: Drawer open or removed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drawer (0x3, 0x0)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_DRAWER_OPENED ( missingDrawer.html )
MEL_EV_EXPANSION_TRAY_THERMAL_SHUTDOWN - 0x285D
This event occurs when: An expansion tray is shutdown for thermal reasons.
Event Name - Expansion Tray Thermal Shutdown
Event description: Expansion tray thermal shutdown
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
MEL_SYMBOL_DATA_TRAYNUMBER
RecoveryFailureType - REC_ENCLOSURE_THERMAL_SHUTDOWN ( thermal_shutdown.html )
MEL_EV_DRAWER_DEGRADED - 0x285F
This event occurs when: Either DCM on the drawer has failed, the drawer is marked as degraded. The drawer needs to be serviced but one DCM is still operational, allowing continued IO to the drives on the drawer. If both DCMs fail, the drawer is marked as failed.
Event Name - Drawer Degraded
Event description: A drawer in the tray has become degraded
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drawer (0x3, 0x0)
MEL_DCMM_DRAWER_PATH_FAIL
RecoveryFailureType - REC_DRAWER_DEGRADED ( degradedDrawer.html )
MEL_EV_DRAWER_INVALID - 0x2861
This event occurs when: An invalid drawer has been detected inside the drive enclosure.
Event Name - Drawer Invalid
Event description: A drawer has been detected that is not valid
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drawer (0x3, 0x0)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_DRAWER_INVALID ( invalidDrawerType.html )
MEL_EV_DRAWER_REMOVED - 0x2862
This event occurs when: A drawer has been removed.
Event Name - Drawer Removed
Event description: A drawer has been removed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Drawer (0x3, 0x0)
MEL_SYMBOL_DATA_SLOTNUMBER
RecoveryFailureType - REC_DRAWER_REMOVED ( removedDrawer.html )
MEL_EV_HOST_SFP_FAILED - 0x2863
This event occurs when: The host-side SFP has failed. It could be failed because it is the wrong type for the protocol in use.
Event Name - Host SFP Removed
Event description: Host-side SFP failed
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller SFP (0x2, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FAILED_TRANSCEIVER_MODULE ( failedGbic.html )
MEL_EV_HOST_SFP_UNSUPPORTED - 0x2864
This event occurs when: The wrong type of host-side SFP has been installed for the protocol in use
Event Name - Host SFP Unsupported
Event description: Host-side SFP unsupported
Event Group - Sub System Monitor
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller SFP (0x2, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FAILED_TRANSCEIVER_MODULE ( failedGbic.html )
MEL_EV_ICM_ENTERING_INVALID_SYSTEM_CONFIG - 0x2900
This event occurs when: The system enters an invalid configuration state as well as every 24 hours if the system remains in that state. When the system is in an invalid configuration state, no configuration changes are allowed -- no new volumes can be created, no new snapshots, no changes of any kind. IO can still be performed to existing user data. Use the recovery guru to correct the invalid configuration state.
Event Name - Entering Invalid System Configuration
Event description: Entering invalid system configuration
Event Group - ICM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_FLASH_CACHE_FAILED_CACHE_SIZE_MISMATCH - 0x3604
This event occurs when: An SSD cache fails due to cache size mismatch on the two controllers.
Event Name - SSD Cache Failed Cache Size Mismatch
Event description: SSD cache failed due to cache size mismatch on the two controllers
Event Group - Flash Cache
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Unknown (0x0)
Event Component Type - SSD Cache (0x3, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_CACHE_MEM_SIZE_MISMATCH ( cacheMismatch.html )
MEL_EV_FLASH_CACHE_NON_OPTIMAL_DRIVES - 0x3605
This event occurs when: An SSD cache has associated non-optimal drives.
Event Name - SSD Cache Non-Optimal Drives
Event description: SSD cache has associated non-optimal drives
Event Group - Flash Cache
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Unknown (0x0)
Event Component Type - SSD Cache (0x3, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FLASH_CACHE_NON_OPTIMAL_DRIVES ( nonOptimalFCdrive.html )
MEL_EV_DISK_POOL_REC_RDRVCNT_BEL_THRSHLD - 0x3803
This event occurs when: An available space reserved for reconstructions within a disk pool falls below the reconstruction reserved disk count value. This occurs when failed drives are rebuilt and use reserved space.
Event Name - Disk Pool Reconstruction Reserved Drive Count Below Threshold
Event description: Disk pool reconstruction reserved drive count is below threshold
Event Group - Disk Pool
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Disk Pool (0x3, 0x2)
MEL_SYMBOL_DATA_RETURNCODE
RecoveryFailureType - REC_DISK_POOL_RECONSTRUCTION_DRIVE_COUNT_BELOW_THRESHOLD ( reservedDriveCountBelowThreshold.html )
MEL_EV_DISK_POOL_UTILIZATION_WARNING - 0x3804
This event occurs when: A pool utilization surpasses the pool utilization warning threshold.
Event Name - Disk pool utilization warning
Event description: Disk pool utilization exceeded the warning threshold
Event Group - Disk Pool
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Disk Pool (0x3, 0x2)
MEL_SYMBOL_DATA_RETURNCODE
RecoveryFailureType - REC_DISK_POOL_UTILIZATION_WARNING ( diskPoolCapacityWarning.html )
MEL_EV_DISK_POOL_UTILIZATION_CRITICAL - 0x3805
This event occurs when: A disk pool utilization surpasses the pool utilization critical threshold.
Event Name - Disk Pool Utilization Critical
Event description: Disk pool utilization exceeded the critical threshold
Event Group - Disk Pool
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Disk Pool (0x3, 0x2)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DISK_POOL_UTILIZATION_CRITICAL ( diskPoolCapacityCritical.html )
MEL_EV_DISK_POOL_CAPACITY_DEPLETED - 0x3809
This event occurs when: A disk pool has completely run out of capacity. This is typically seen when reconstruction operations consume all of the capacity while trying to recover from drive failures.
Event Name - Disk Pool Capacity Depleted
Event description: All of the disk pool's free capacity has been used
Event Group - Disk Pool
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Disk Pool (0x3, 0x2)
MEL_SYMBOL_DATA_RETURNCODE
RecoveryFailureType - REC_DISK_POOL_CAPACITY_DEPLETED ( diskPoolCapacityFull.html )
MEL_EV_DISK_POOL_INSUFFICIENT_MEMORY - 0x380C
This event occurs when: A disk pool configuration has insufficient memory.
Event Name - Disk Pool Insufficient Memory
Event description: Disk pool configuration has insufficient memory
Event Group - Disk Pool
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DISK_POOL_INSUFFICIENT_MEMORY ( diskPoolInsuffMemory.html )
MEL_EV_DISK_POOL_CORRUPTED_DB_RECORD - 0x380D
This event occurs when: A disk pool corrupts database record.
Event Name - Disk Pool Corrupted DB Record
Event description: Disk pool has corrupted database record
Event Group - Disk Pool
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_VOL_XFER_ALERT - 0x4011
This event occurs when: A "volume not on preferred path" condition persists longer than the alert delay period. Some OEM customers classify this as an informational event, others as a critical event.
Event Name - Vol Xfer Alert
Event description: Volume not on preferred path due to AVT/RDAC failover
Event Group - RDAC, Quiescence and ICON Mgr
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_SYMBOL_CONT_FAIL - 0x5005
This event occurs when: Logged on entry to setControllerToFailed_1.
Event Name - Set Controller Failed
Event description: Place controller offline
Event Group - SYMbol Server
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Command (0x3)
Event Component Type - Controller (0x0, 0x8)
MEL_SYMBOL_DATA_CONTROLLER_NUMBER
RecoveryFailureType - N/A
MEL_EV_SYMBOL_AUTH_FAIL_CONT_LOCKOUT - 0x5038
This event occurs when: A lockout state has been entered.
Event Name - SYMbol Auth Fail Cont Lockout
Event description: Storage array 10-minute lockout; maximum incorrect passwords attempted
Event Group - SYMbol Server
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_AUTH_DATA
RecoveryFailureType - N/A
MEL_EV_SYMBOL_CONT_SERVICE_MODE - 0x5040
This event occurs when: A controller is placed in service mode.
Event Name - SYMbol Cont Service Mode
Event description: Place controller in service mode
Event Group - SYMbol Server
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Command (0x3)
Event Component Type - Controller (0x0, 0x8)
MEL_SYMBOL_DATA_CONTROLLER_NUMBER
RecoveryFailureType - N/A
MEL_EV_LOCK_KEY_VALID_ATTEMPTS_EXCEEDED - 0x506D
This event occurs when: The number of attempts to validate the lock key has exceeded the threshold.
Event Name - Lock Key Failed Validation Attempts Exceeded
Event description: Security (FDE) key failed validation attempts due to excessive tries
Event Group - SYMbol Server
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Command (0x3)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SECURITY_KEY_VALIDATION_LOCK ( securityKeyValidationLock.html )
MEL_EV_BASE_CONTROLLER_DIAGNOSTIC_FAILED - 0x5100
This event occurs when: One or more diagnostic tests detects that one or more component within the base controller is not functioning as desired.
Event Name - Base Controller Diagnostic Failed
Event description: Base controller diagnostic failed
Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_CONTROLLER_ID
RecoveryFailureType - REC_BASE_CONTROLLER_DIAG_FAILED ( offlineCtl.html )
MEL_EV_IOC_CONTROLLER_FAILURE - 0x5101
This event occurs when: One or more diagnostic tests detected that one or more component on the alternate controller is not functioning as desired. As a result, the alternate controller is locked down.
Event Name - Base Controller Diagnostic On Alternate Controller Failed
Event description: Base controller diagnostic on alternate controller failed
Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_IOC_DIAG_FAIL ( ctrlIocDiagFailed.html )
MEL_EV_IOC_FAILURE - 0x5102
This event occurs when: An IOC diagnostic test has detected a failure. As a result, the controller is locked down.
Event Name - IOC Fault Diagnostic Failure
Event description: IOC fault diagnostic failure has been detected
Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_CONTROLLER_ID
RecoveryFailureType - REC_IOC_DIAG_FAIL ( ctrlIocDiagFailed.html )
MEL_EV_SAS_PHY_DISABLED_BYPASSED_PORT - 0x5103
This event occurs when: One of the PHYs on a wide port is disabled. The wide ports are used only between the IOC and either the local or the partner controller's expander. The bad hardware would be one of the controllers or the mid-plane.
Event Name - SAS PHY Disabled Bypassed Port
Event description: SAS PHY disabled bypassed port
Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Failure (0x2)
Event Component Type - Channel (0x0, 0x6)
MEL_DATA_SASFI_PHY_ERROR_BCAST
RecoveryFailureType - N/A
MEL_EV_SAS_PHY_DISABLED_BYPASSED_DRIVE - 0x5104
This event occurs when: A PHY that is connected to a drive is disabled. The error could be in the expander or drive. This event is generated only when the controller disables a PHY not the ESM. The easiest replacement option is the drive, so it should be called out as the first choice for replacement.
Event Name - SAS PHY Disabled Bypassed Drive
Event description: SAS PHY disabled bypassed drive
Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Failure (0x2)
Event Component Type - Channel (0x0, 0x6)
MEL_DATA_SASFI_PHY_ERROR_BCAST
RecoveryFailureType - N/A
MEL_EV_SAS_PHY_DISABLED_LOCAL_WIDE_PORT - 0x5105
This event occurs when: A bad SAS PHY has disabled the local wide port.
Event Name - SAS PHY Disabled Local Wide Port
Event description: SAS PHY disabled local wide port
Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Channel (0x0, 0x6)
MEL_DATA_SASFI_PHY_ERROR_PHYNUM
RecoveryFailureType - REC_SAS_PHY_DISABLED_LOCAL_WIDE_PORT_DEGRADED ( chanSASPhyDisabledLocalWidePortDegraded.html )
MEL_EV_SAS_PHY_DISABLED_SHARED_WIDE_PORT - 0x5106
This event occurs when: A bad SAS PHY has disabled a shared wide port.
Event Name - SAS PHY Disabled Shared Wide Port
Event description: SAS PHY disabled shared wide port
Event Group - Base Controller Diagnostic
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Channel (0x0, 0x6)
MEL_DATA_SASFI_PHY_ERROR_PHYNUM
RecoveryFailureType - REC_SAS_PHY_DISABLED_SHARED_WIDE_PORT_DEGRADED ( chanSASPhyDisabledSharedWidePortDegraded.html )
MEL_EV_SPM_INVALID_HOST_OS_INDEX_DETECTED - 0x5222
This event occurs when: A host index has been detected that is considered to be invalid due to NVSRAM settings.
Event Name - Invalid Host OS Index Detected
Event description: Invalid host OS index detected
Event Group - SPM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Host (0x2, 0xF)
MEL_SPM_DATA_NOTIFY_INVALID_OSINDEX
RecoveryFailureType - REC_INVALID_HOST_TYPE_INDEX ( invalidHostType.html )
MEL_EV_SPM_INVALID_DEFAULT_OS_INDEX_DETECTED - 0x5223
This event occurs when: The default OS index is invalid.
Event Name - Invalid Default OS Index Detected
Event description: Invalid default OS index detected
Event Group - SPM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Relative (0x0, 0x0)
MEL_SPM_DATA_NOTIFY_INVALID_OSINDEX
RecoveryFailureType - REC_INVALID_HOST_TYPE_INDEX ( invalidHostType.html )
MEL_EV_INACTIVE_HOST_PORT_REGISTERED - 0x5224
This event occurs when: A Host Context Agent (HCA) attempted to register a host port associated with a host that already has storage partition mappings. The host port was consequently marked inactive and can be activated through the storage management software or CLI.
Event Name - Inactive Host Port Registered
Event description: Inactive host port registered
Event Group - SPM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Host Port (0x0, 0xF)
MEL_SPM_DATA_HCA_REGISTRATION
RecoveryFailureType - REC_INACTIVE_HOST_PORT
MEL_EV_INACTIVE_INITIATOR_REGISTERED - 0x5225
This event occurs when: A Host Context Agent (HCA) attempted to register an iSCSI initiator associated with a host that already has storage partition mappings. The iSCSI initiator was consequently marked inactive and can be activated through the storage management software.
Event Name - Inactive Initiator Registered
Event description: Inactive initiator registered
Event Group - SPM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - iSCSI Initiator (0x2, 0x9)
MEL_SPM_DATA_HCA_REGISTRATION
RecoveryFailureType - REC_INACTIVE_INITIATOR ( inactiveHostIdentifier.html )
MEL_EV_SAFE_NON_COMPLIANCE - 0x5402
This event occurs when: There are features enabled that have not been purchased.
Event Name - Non-Compliance
Event description: Premium feature out of compliance
Event Group - SAFE
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Relative (0x0, 0x0)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_EXTERNAL_KMS_NOT_COMPLIANT ( extKMSNonCompliant.html )
MEL_EV_SAFE_TIER_NON_COMPLIANCE - 0x5403
This event occurs when: The limits of a premium feature have been exceeded (e.g. 6 storage partitions mapped when 4 have been purchased).
Event Name - Tier Non-Compliance
Event description: Premium feature exceeds limit
Event Group - SAFE
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Relative (0x0, 0x0)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SNAPSHOT_NOT_COMPLIANT ( nonCompliantSnapshot.html )
MEL_EV_SAFE_MISMATCHED_GK_DEP - 0x5405
This event occurs when: Each controller of the pair has a different setting for the NVSRAM bit that controls whether or not the controller is subject to Gold Key restrictions. When this condition is detected, both controllers are treated as though they are subject to the restrictions.
Event Name - Mismatched Gold Key Settings
Event description: Gold Key - mismatched settings
Event Group - SAFE
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Relative (0x0, 0x0)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MISMATCHED_GOLD_KEY_SETTINGS
MEL_EV_SAFE_MISMATCHED_MDT_DEP - 0x5406
This event occurs when: Each controller of the pair has a different setting for the NVSRAM bit that controls whether or not Mixed Drive Types is a premium feature. When this condition is detected, both controllers are treated as though MDT is a premium feature.
Event Name - Mismatched Mixed Drive Type Settings
Event description: Mixed drive types - mismatched settings
Event Group - SAFE
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Relative (0x0, 0x0)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MISMATCHED_MDT_SETTINGS
MEL_EV_SAFE_EVAL_EXPIRATION_IMMINENT - 0x5409
This event occurs when: The trial period for a feature license is very near expiration.
Event Name - Feature Evaluation Period Expiration Is Imminent
Event description: Feature evaluation period expiration is imminent
Event Group - SAFE
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Notification (0x4)
Event Component Type - Relative (0x0, 0x0)
MEL_DATA_EVAL_MEL_DATA
RecoveryFailureType - REC_EVALUATION_LICENSE_EXPIRATION_IMMINENT ( featureTrialNearExpiration.html )
MEL_EV_DIAG_READ_FAILURE - 0x560D
This event occurs when: Runtime Diagnostics Read test failed on this controller.
Event Name - Runtime Diagnostics error Diagnostic read test failed
Event description: Diagnostics read test failed on controller
Event Group - Runtime Diagnostics
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_DIAG_TEST_ID
RecoveryFailureType - N/A
MEL_EV_DIAG_READ_FAILURE_ALT - 0x560E
This event occurs when: Runtime Diagnostics Read test failed on the alternate controller.
Event Name - Runtime Diagnostics error Diagnostic read failure on alternate controller
Event description: This controller's alternate failed diagnostics read test
Event Group - Runtime Diagnostics
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DIAG_WRITE_FAILURE - 0x560F
This event occurs when: Runtime Diagnostics Write test failed on this controller.
Event Name - Runtime Diagnostics error Diagnostic write test failed
Event description: Diagnostics write test failed on controller
Event Group - Runtime Diagnostics
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_DIAG_TEST_ID
RecoveryFailureType - N/A
MEL_EV_DIAG_WRITE_FAILURE_ALT - 0x5610
This event occurs when: Runtime Diagnostics Write test failed on the alternate controller.
Event Name - Runtime Diagnostics error Diagnostic write test failed on alternate controller
Event description: This controller's alternate failed diagnostics write test
Event Group - Runtime Diagnostics
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DIAG_CONFIG_ERR - 0x5616
This event occurs when: A configuration error occurs on this controller for running diagnostics.
Event Name - Runtime Diagnostics error Configuration error
Event description: Diagnostics rejected configuration error on controller
Event Group - Runtime Diagnostics
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DIAG_CONFIG_ERR_ALT - 0x5617
This event occurs when: A configuration error of the alternate controller occurs for running diagnostics.
Event Name - Runtime Diagnostics error Alternate controller configuration error
Event description: Diagnostics rejected - configuration error on this controller's alternate
Event Group - Runtime Diagnostics
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
MEL_DATA_DIAG_TEST_ID
RecoveryFailureType - N/A
MEL_EV_DBM_CONFIG_DB_FULL - 0x6101
This event occurs when: An internal configuration database is full. This error has never been reported. If this were to occur, the system would operate normally but no configuration changes that created additional objects would be allowed. The customer should contact support if this event is logged. There is no recovery action for the customer.
Event Name - DBM Config DB Full
Event description: Internal configuration database full
Event Group - Hierarchical Config DB
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DBM_HCK_ALTCTL_NOT_FUNC - 0x6107
This event occurs when: A controller's alternate is non-functional and is being held in reset.
Event Name - DBM Hck Altctl Not Func
Event description: This controller's alternate is non-functional and is being held in reset
Event Group - Hierarchical Config DB
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_OFFLINE_CTL ( offlineCtl.html )
MEL_EV_DATABASE_RECOVERY_MODE_ACTIVE - 0x6109
This event occurs when: The controller is booting up in database recovery mode, with no configuration. The backup database images are locked in read-only mode. The storage administrator is expected to recreate the configuration, using the database backup images.
Event Name - Database is in recovery mode
Event description: The controller is booting up in database recovery mode
Event Group - Hierarchical Config DB
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DATABASE_RECOVERY_MODE ( configDbRecoveryMode.html )
MEL_EV_MIRROR_DUAL_PRIMARY - 0x6400
This event occurs when: There is a conflict over the primary volume. Since both sides of the mirrored pair are in the same Primary role, both storage arrays will report this MEL event.
Event Name - Mirror Dual Primary
Event description: Dual primary volume conflict
Event Group - Mirroring
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MIRROR_DUAL_PRIMARY ( mirrorDualPrimary.html )
MEL_EV_MIRROR_DUAL_SECONDARY - 0x6401
This event occurs when: There is a conflict over the secondary volume. Since both sides of the mirrored pair are in the same Secondary role, both storage arrays will report this MEL event.
Event Name - Mirror Dual Secondary
Event description: Dual secondary volume conflict
Event Group - Mirroring
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MIRROR_DUAL_SECONDARY ( mirrorDualSecondary.html )
MEL_EV_MIRROR_UNSYNCHRONIZED - 0x6402
This event occurs when: A mirror state transitions to the unsynchronized state from either the synchronizing or optimal state.
Event Name - Mirror Unsynchronized
Event description: Data on mirrored pair unsynchronized
Event Group - Mirroring
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MIRROR_UNSYNCHRONIZED ( mirrorUnsync.html )
MEL_EV_RVM_WRITE_MODE_INCONSISTENT - 0x6411
This event occurs when: The mirror relationship has inconsistent write mode.
Event Name - RVM Write Mode Inconsistent
Event description: Mirror relationship has inconsistent write mode
Event Group - Mirroring
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_RVM_WRITE_MODE_INCONSISTENT
MEL_EV_RMTVOL_LINK_DOWN - 0x6503
This event occurs when: A link is down.
Event Name - RMTVOL Link Down
Event description: Communication to remote volume down
Event Group - Remote Volume
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_REMOTE_NO_ARRAY ( remoteNoArray.html )
MEL_EV_RMTVOL_WWN_CHANGE_FAILED - 0x6505
This event occurs when: This error occurs if an array detects during start-up processing that its WWN changed. When the firmware detects this name change, it attempts to notify any remote array that had previously been participating in a mirroring relationship. This event has been replaced with 0x6507.
Event Name - RMTVOL Node WWN Changed Failed
Event description: Failed to communicate storage array's world-wide name
Event Group - Remote Volume
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume (0x0, 0xD)
MEL_DATA_RMTVOL_NODE_WWN_CHANGED
RecoveryFailureType - REC_REMOTE_WWN_CHANGE_FAILED ( wwnChangeFailed.html )
MEL_EV_VOLCOPY_FAILED - 0x6600
This event occurs when: A volume copy operation fails due to one of the following reasons: Read error on source volume, Write error on target volume, Configuration change resulting in a feature compatibility violation (e.g. Role Change of a Remote Mirror).
Event Name - VOLCOPY Failed
Event description: Volume copy operation failed
Event Group - Volume Copy
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume (0x0, 0xD)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_VOLCOPY_FAILED ( copyFailed.html )
MEL_EV_USM_BAD_LBA_DETECTED - 0x6700
This event occurs when: An unreadable sector is detected and data loss occurred.
Event Name - USM BAD LBA Detected
Event description: Unreadable sector(s) detected data loss occurred
Event Group - Unreadable Sector Management
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Volume (0x0, 0xD)
MEL_DATA_USM_UNREADABLE_SECTOR
RecoveryFailureType - REC_USM_UNREADABLE_SECTORS_EXIST ( UnreadableSctrs.html )
MEL_EV_USM_DATABASE_FULL - 0x6703
This event occurs when: A database is full.
Event Name - USM Database Full
Event description: Overflow in unreadable sector database
Event Group - Unreadable Sector Management
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Volume (0x0, 0xD)
MEL_DATA_USM_UNREADABLE_SECTOR
RecoveryFailureType - REC_USM_DATABASE_FULL ( UnreadableSctrsLogFull.html )
MEL_EV_SPRI_ACTIVATED - 0x6800
This event occurs when: A Service Interface has been activated. This event is a security measure and does not cause a Needs Attention condition on the array.
Event Name - SPRI Activated
Event description: Support Recovery Interface (SPRI) activated
Event Group - Support and Recovery Interface
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_SPRI_WRONG_PASSWORD - 0x6801
This event occurs when: A controller detects that a wrong password or corrupted password has been entered. This event is a security measure and does not cause a Needs Attention condition on the array.
Event Name - SPRI Wrong Password
Event description: Support Recovery Interface (SPRI) wrong password
Event Group - Support and Recovery Interface
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_DDC_AVAILABLE_CRITICAL - 0x6900
This event occurs when: An unusual event on the controller has triggered the DDC feature to store diagnostic data.
Event Name - DDC Available
Event description: Diagnostic data is available
Event Group - DDC
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Notification (0x4)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_DDC_AVAILABLE ( diagnosticDataCapture.html )
MEL_EV_FBM_BUNDLE_VIOLATION - 0x7001
This event occurs when: A RAID controller detects that one or more features are enabled that violate the current Sub-Model definition.
Event Name - FBM Bundle Violation
Event description: Feature pack key file required
Event Group - Feature Bundle Management
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Error (0x1)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_FEATURE_NOT_COMPLIANT ( nonCompliantFeature.html )
MEL_EV_BBU_OVERHEATED - 0x7300
This event occurs when: The BBU is overheated.
Event Name - BBU Overheated
Event description: Battery backup unit overheated
Event Group - Battery Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
MEL_DATA_SMART_BATTERY
RecoveryFailureType - REC_BATTERY_OVERTEMP ( batteryOverTemp.html )
MEL_EV_INSUFFICIENT_LEARNED_CAPACITY - 0x7301
This event occurs when: Measured capacity of the BBU is insufficient to hold cache data for at least 72 hours.
Event Name - Insufficient Learned Capacity
Event description: Insufficient learned battery capacity
Event Group - Battery Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
MEL_DATA_SMART_BATTERY
RecoveryFailureType - REC_BATTERY_WARN ( batteryReplacementRequired.html )
MEL_EV_BATTERY_MISSING - 0x7306
This event occurs when: Information not available.
Event Name - Battery Missing
Event description: Battery missing
Event Group - Battery Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
MEL_DATA_SMART_BATTERY
RecoveryFailureType - REC_REMOVED_BATTERY ( batteryRemoved.html )
MEL_EV_BATTERY_EXPIRED - 0x7308
This event occurs when: Information not available.
Event Name - Battery Expired
Event description: Battery expired
Event Group - Battery Manager
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Battery Pack (0x0, 0x9)
MEL_DATA_SMART_BATTERY
RecoveryFailureType - REC_EXPIRED_BATTERY ( batteryExpired.html )
MEL_EV_CACHE_BACKUP_DEVICE_FAILED - 0x7500
This event occurs when: The persistent cache backup device has failed.
Event Name - Cache Backup Device Failed
Event description: Persistent cache backup device has failed
Event Group - Persistent Cache Backup
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Cache Backup Device (0x2, 0xC)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_CACHE_BACKUP_DEVICE_FAILED ( failedCacheBackupDev.html )
MEL_EV_CACHE_BACKUP_DEV_WRITE_PROTECTED - 0x7501
This event occurs when: Write protection is enabled on the cache backup device.
Event Name - Cache Backup Device Write-Protected
Event description: Cache backup device is write-protected
Event Group - Persistent Cache Backup
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Cache Backup Device (0x2, 0xC)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_CACHE_BACKUP_DEVICE_WRITE_PROTECTED ( cacheBackupDevWriteProtect.html )
MEL_EV_BACKUP_COMPONENT_STATUS_UNKNOWN - 0x7506
This event occurs when: The status of the cache backup device is unknown because of a communication failure with the device.
Event Name - Backup Component Status Unknown
Event description: Backup component status unknown
Event Group - Persistent Cache Backup
Event Priority - CRITICAL_EVENT
Log Group - Controller (0x1)
Event Category - Failure (0x2)
Event Component Type - Controller (0x0, 0x8)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - N/A
MEL_EV_PIT_ROLLBACK_PAUSED - 0x7800
This event occurs when: A PiT rollback operation has been paused.
Event Name - PiT Rollback Paused
Event description: Snapshot image rollback paused
Event Group - Pit Group Support
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Snapshot Image (0x3, 0x3)
MEL_DATA_VDD_STATUS
RecoveryFailureType - REC_PIT_ROLLBACK_PAUSED ( pitRollbackPaused.html )
MEL_EV_PITGROUP_REPOSITORY_FULL - 0x7802
This event occurs when: The PiT group repository is full -- the current allocation has been consumed.
Event Name - PiT Group Repository Full
Event description: Snapshot group repository full
Event Group - Pit Group Support
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD), Consistency Group (0x3, 0x5)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_PIT_GROUP_REPOSITORY_FULL ( pgCGMemberReposFull.html )
MEL_EV_PITGROUP_FAILED - 0x7803
This event occurs when: A failure with a PiT group has been detected.
Event Name - PiT Group Failed
Event description: Snapshot group failed
Event Group - Pit Group Support
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD), Consistency Group (0x3, 0x5)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_PIT_GROUP_FAILED ( failedPgCgMember.html )
MEL_EV_VIEW_REPOSITORY_FULL - 0x7805
This event occurs when: The view repository is full -- the current allocation has been consumed.
Event Name - View Repository Full
Event description: Snapshot volume repository full
Event Group - Pit Group Support
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD), Consistency Group Snapshot Volume (0x3, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_PIT_VIEW_REPOSITORY_FULL ( pitVolumeRepositoryFull.html )
MEL_EV_VIEW_REPOSITORY_FAILED - 0x7806
This event occurs when: A failure has been detected with a view repository.
Event Name - View Repository Failed
Event description: Snapshot volume repository failed
Event Group - Pit Group Support
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD), Consistency Group Snapshot Volume (0x3, 0x6)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_PIT_VIEW_FAILED ( failedPiTVolume.html )
MEL_EV_PIT_PURGED - 0x7807
This event occurs when: A PiT has been purged.
Event Name - PiT Purged
Event description: Snapshot image purged
Event Group - Pit Group Support
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Snapshot Image (0x3, 0x3)
MEL_DATA_LBA_BLOCK
RecoveryFailureType - REC_PIT_PURGED ( pitPurged.html )
MEL_EV_TPV_REPOSITORY_FULL - 0x7B01
This event occurs when: A TPV Repository has no more capacity available to accept WRITE operations.
Event Name - TPV Repository Capacity Full
Event description: A thin volume repository is full
Event Group - Thin Provisioned Volume (TPV)
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD)
MEL_DATA_VOL_LABEL
RecoveryFailureType - REC_TPV_REPOSITORY_FULL ( thinVolumeRepositoryFull.html )
MEL_EV_TPV_REPOSITORY_FAILED - 0x7B02
This event occurs when: A TPV transitions to a failed state.
Event Name - TPV Repository Failed
Event description: A thin volume repository has failed
Event Group - Thin Provisioned Volume (TPV)
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD)
MEL_DATA_VOL_LABEL
RecoveryFailureType - REC_TPV_FAILED ( failedThinVolume.html )
MEL_EV_ARVM_AMG_INTERNAL_SUSPENSION - 0x7C02
This event occurs when: A controller firmware internally suspends synchronization for an AMG. This usually is the result of an error condition that requires user intervention to resolve.
Event Name - Async Mirror Group Sync Internal Suspension
Event description: An asynchronous mirror group was suspended internally
Event Group - ARVM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Asynchronous Mirror Group (0x3, 0x7)
MEL_DATA_AMG_REF
RecoveryFailureType - REC_ARVM_SYNC_INTERNALLY_SUSPENDED ( syncSuspended.html )
MEL_EV_ARVM_AMG_ROLE_CONFLICT - 0x7C03
This event occurs when: An AMG role conflict is detected by the controller firmware.
Event Name - Async Mirror Group Role Conflict
Event description: The asynchronous mirror group has a role (primary or secondary) conflict
Event Group - ARVM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Asynchronous Mirror Group (0x3, 0x7)
MEL_DATA_AMG_REF
RecoveryFailureType - REC_ARVM_MIRROR_GROUP_ROLE_CONFLICT ( amgRoleConflict.html )
MEL_EV_ARVM_AMG_RECOVERY_POINT_LOST - 0x7C04
This event occurs when: An AMG's recovery point is lost.
Event Name - Async Mirror Group Recovery Point Lost
Event description: A recovery point for an asynchronous mirror group was lost
Event Group - ARVM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Asynchronous Mirror Group (0x3, 0x7)
MEL_DATA_AMG_REF
RecoveryFailureType - REC_ARVM_MIRROR_GROUP_RECOVERY_POINT_LOST ( lostRecoveryPoint.html )
MEL_EV_ARMV_MIRROR_FAILED - 0x7C06
This event occurs when: A controller firmware detects an error condition that results in the mirror being failed. This will result in an internally suspended mirror.
Event Name - Async Mirror Group Member Failed
Event description: Asynchronous mirror group member has failed
Event Group - ARVM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Volume (0x0, 0xD)
MEL_DATA_AMG_MEMBER_FAIL_STOP
RecoveryFailureType - REC_ARVM_FAILED_MIRROR ( failedMirror.html )
MEL_EV_ARVM_AMG_SEC_MEM_REP_FULL - 0x7C09
This event occurs when: A secondary repository's utilization is at capacity resulting in an internally suspended synchronization so that the user can determine how to resolve the condition.
Event Name - Async Mirror Group Secondary Member Repository Full
Event description: An asynchronous mirror group secondary member repository is full
Event Group - ARVM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Volume (0x0, 0xD)
MEL_DATA_AMG_MEMBER_REF
RecoveryFailureType - REC_ARVM_SECONDARY_REPOSITORY_FULL ( mirrorReposFullSecondary.html )
MEL_EV_ARVM_AMG_SYNC_PAUSED_ALT_STATE - 0x7C34
This event occurs when: An AMG's synchronization becomes paused because the alternate state is preventing synchronization from proceeding.
Event Name - Async Mirror Group Sync Paused Alt State
Event description: An asynchronous mirror group's synchronization has paused because the alternate state is preventing synchronization from proceeding
Event Group - ARVM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Failure (0x2)
Event Component Type - Asynchronous Mirror Group (0x3, 0x7)
MEL_DATA_AMG_REF
RecoveryFailureType - REC_ARVM_SYNC_PAUSED_ALT_STATE ( syncPaused.html )
MEL_EV_ARVM_AMG_ROLE_CHANGE_PAUSED - 0x7C37
This event occurs when: The controller firmware detects that the role change for an AMG has been paused.
Event Name - Async Mirror Group Mirror Role Change Requested
Event description: Controller firmware detected a role change for an AMG has been paused
Event Group - ARVM
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Asynchronous Mirror Group (0x3, 0x7)
MEL_DATA_AMG_REF
RecoveryFailureType - REC_ARVM_ROLE_CHANGE_PAUSED ( remoteNoArray.html )
MEL_EV_SCT_COMMAND_UNSUPPORTED - 0x7D00
This event occurs when: Logged by MEL event VDM.
Event Name - SCT Commands Unsupported
Event description: SMART Command Transfer (SCT) commands unsupported
Event Group - Native SATA Drive
Event Priority - CRITICAL_EVENT
Log Group - Drive (0x2)
Event Category - Failure (0x2)
Event Component Type - Drive (0x0, 0x1)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_INCOMPATIBLE_SATA_DRIVE ( incompatibleSATAdrive.html )
MEL_EV_HOST_REDUNDANCY_LOST - 0x9102
This event occurs when: The controller has detected that the specified host has lost connection to one of the two controllers.
Event Name - Host Connection Redundancy Lost
Event description: Loss of host-side connection redundancy detected
Event Group - AutoLoadBalancing
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Host (0x2, 0xF)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_HOST_REDUNDANCY_LOST
MEL_EV_MULTIPATH_CONFIG_ERROR - 0x9103
This event occurs when: The behavior exhibited by the host multipath driver for the specified host does not match expectations of the supported driver(s) for the specified host type. This usually indicates a missing, out-of-date, or misconfigured multipath driver installed on the host or an incorrect host type specified for this host in the array configuration.
Event Name - Multipath Configuration Error
Event description: Host multipath driver configuration error detected
Event Group - AutoLoadBalancing
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Host (0x2, 0xF)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MULTIPATH_CONFIGURATION_ERROR
MEL_EV_SECURITY_AUDIT_LOG_FULL - 0x9200
This event occurs when: The Security Audit Log has reached its maximum capacity, and the Audit Log Full Policy is set to 'Manually Clear'.
Event Name - Security Audit Log Full
Event description: Security Audit Log has reached its maximum capacity and cannot record new security audit events until it is cleared
Event Group - Security Events
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Notification (0x4)
Event Component Type - Enclosure (0x0, 0xA)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_SECURITY_AUDIT_LOG_FULL
MEL_EV_DIRECTORY_SERV_CONFIG_ERROR - 0x9204
This event occurs when: The controller is unable to communicate with the configured Directory Services server.
Event Name - Directory Services Server Configuration Error
Event description: A Directory Services server is unreachable or misconfigured
Event Group - Security Events
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Enclosure (0x0, 0xA)
MEL_DATA_DIRECTORY_SERVICES_DOMAIN
RecoveryFailureType - REC_DIRECTORY_SERVICES_CONFIG_ERROR