Complete software and firmware upgrade

You can complete the software and firmware upgrade by verifying the versions in ThinkSystem System Manager's Software and Firmware Inventory dialog box.

Before you begin

  • You must have activated your software or firmware.
  1. Verify that all components appear on the Hardware page.
  2. Verify the new software and firmware versions by checking the Software and Firmware Inventory dialog box (go to Support > Upgrade Center, and then click the link for Software and Firmware Inventory).
  3. If you upgraded controller NVSRAM, any custom settings that you have applied to the existing NVSRAM are lost during the process of activation. You need to apply the custom settings to the NVSRAM again after the process of activation is complete.
  4. If any of the following errors occur during the upgrade procedure, take the appropriate recommended action.
    If you encounter this firmware download error...Then do the following...
    Failed assigned drives

    One reason for the failure might be that the drive does not have the appropriate signature. Make sure that the affected drive is an authorized drive. Contact technical support for more information.

    When replacing a drive, make sure that the replacement drive has a capacity equal to or greater than the failed drive you are replacing.

    You can replace the failed drive while the storage array is receiving I/O.

    Check storage array

    • Make sure that an IP address has been assigned to each controller.
    • Make sure that all cables connected to the controller are not damaged.
    • Make sure that all cables are tightly connected.

    Integrated hot spare drives

    This error condition must be corrected before you can upgrade the firmware. Launch System Manager and use the Recovery Guru to resolve the problem.

    Incomplete volume groups

    If one or more volume groups or disk pools are incomplete, you must correct this error condition before you can upgrade the firmware. Launch System Manager and use the Recovery Guru to resolve the problem.

    Exclusive operations (other than background media/parity scan) currently running on any volume groups

    If one or more exclusive operations are in progress, the operations must complete before the firmware can be upgraded. Use System Manager to monitor the progress of the operations.

    Missing volumes

    You must correct the missing volume condition before the firmware can be upgraded. Launch System Manager and use the Recovery Guru to resolve the problem.

    Either controller in a state other than Optimal

    One of the storage array controllers needs attention. This condition must be corrected before the firmware can be upgraded. Launch System Manager and use the Recovery Guru to resolve the problem.

    Mismatched Storage Partition information between Controller Object Graphs

    An error occurred while validating the data on the controllers. Contact technical support to resolve this issue.

    SPM Verify Database Controller check fails

    A storage partitions mapping database error occurred on a controller. Contact technical support to resolve this issue.

    Configuration Database Validation (If supported by the storage array’s controller version)

    A configuration database error occurred on a controller. Contact technical support to resolve this issue.

    MEL Related Checks

    Contact technical support to resolve this issue.

    More than 10 DDE Informational or Critical MEL events were reported in the last 7 days

    Contact technical support to resolve this issue.

    More than 2 Page 2C Critical MEL Events were reported in the last 7 days

    Contact technical support to resolve this issue.

    More than 2 Degraded Drive Channel Critical MEL events were reported in the last 7 days

    Contact technical support to resolve this issue.

    More than 4 critical MEL entries in the last 7 days

    Contact technical support to resolve this issue.

Your controller software upgrade is complete. You can resume normal operations.