80070219-0701ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (Sys Board Fault)
Sensor [SensorElementName] has transitioned to critical from a less severe state. (Sys Board Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.
May also be shown as 800702190701ffff or 0x800702190701ffff
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
50
Automatically Notify Support
No
User Response
- Check for an error LED on the system board.
- Check the system-event log.
- Check for the system firmware version and update to the latest version. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
- Unplug and restore AC power cord, then, perform step 1 and 2 again.
- If problems still occurred, (trained technician only) replace the system board.
Give documentation feedback