Test results for the DSA memory stress test
The following messages can result when you run the DSA memory stress test.
202-000-000 : MemStr Test Passed
Test Passed.- Recoverable
- No
- Severity
- Event
- Serviceable
- No
- Automatically notify support
- No
- Related links
202-801-000 : MemStr Test Aborted
Internal program error.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Turn off and restart the system.
- Make sure that the DSA Diagnostic code is at the latest level.
- Run the test again.
- If the system has stopped responding, turn off and restart the system.
- Check the system firmware level and upgrade if necessary.
- Run the memory diagnostic to identify the specific failing DIMM.
- If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
202-802-000 : MemStr Test Aborted
Memory size is insufficient to run the test. At least 1 GB is required.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- Related links
202-803-000 : MemStr Test Aborted
User pressed Ctrl-C.- Recoverable
- No
- Severity
- Warning
- Serviceable
- Yes
- Automatically notify support
- No
- Related links
202-901-000 : MemStr Test Failed
Test Failed.- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Execute the standard DSA memory diagnostics to validate all memory.
- Make sure that the DSA Diagnostic code is at the latest level.
- Turn off the system and disconnect it from power.
- Reseat the memory cards and DIMMs.
- Reconnect the system to power and turn the system on.
- Run the test again.
- Execute the standard DSA memory diagnostics to validate all memory.
- If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
202-902-000 : MemStr Test Failed
Memory size is insufficient to run the test.- Recoverable
- No
- Severity
- Error
- Serviceable
- Yes
- Automatically notify support
- No
- User Response
- Complete the following steps:
- Ensure that all memory is enabled by checking the "Available System Memory" in the "Resource Utilization" section of the DSA Diagnostic Event log.
- If necessary, access the Configuration/Setup Utility program by pressing F1 during system boot and enable all memory.
- Make sure that the DSA Diagnostic code is at the latest level.
- Run the test again.
- Execute the standard DSA memory diagnostics to validate all memory.
- If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
- Related links
Give documentation feedback