806f0021-2582ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. (PCIe Error)
Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. (PCIe Error)
This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00212582ffff or 0x806f00212582ffff
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
50
Automatically Notify Support
Yes
User Response
- Check the PCI LED.
- Reseat the affected adapters and riser card.
- Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
- Replace the affected adapters.
- Replace the riser card.
- (Trained service technicians only) Replace the system board.
Give documentation feedback