List of IMM events

This section lists all messages that can be sent from the IMM.

  • 40000001-00000000 : Management Controller [arg1] Network Initialization Complete. ()

    This message is for the use case where a Management Controller network has completed initialization.

    May also be shown as 4000000100000000 or 0x4000000100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - IMM Network event
    SNMP Trap ID
    37
    CIM Information
    Prefix: IMM ID: 0001
    User Response
    Information only; no action is required.
  • 40000002-00000000 : Certificate Authority [arg1] has detected a [arg2] Certificate Error. ()

    This message is for the use case when there is an error with an SSL Server, SSL Client, or SSL Trusted CA Certificate.

    May also be shown as 4000000200000000 or 0x4000000200000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - SSL certification
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0002
    User Response
    Make sure that the certificate that you are importing is correct and properly generated.
  • 40000003-00000000 : Ethernet Data Rate modified from [arg1] to [arg2] by user [arg3]. ()

    This message is for the use case where a user modifies the Ethernet Port data rate.

    May also be shown as 4000000300000000 or 0x4000000300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0003
    User Response
    Information only; no action is required.
  • 40000004-00000000 : Ethernet Duplex setting modified from [arg1] to [arg2] by user [arg3]. ()

    This message is for the use case where A user modifies the Ethernet Port duplex setting.

    May also be shown as 4000000400000000 or 0x4000000400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0004
    User Response
    Information only; no action is required.
  • 40000005-00000000 : Ethernet MTU setting modified from [arg1] to [arg2] by user [arg3]. ()

    This message is for the use case where a user modifies the Ethernet Port MTU setting.

    May also be shown as 4000000500000000 or 0x4000000500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0005
    User Response
    Information only; no action is required.
  • 40000006-00000000 : Ethernet locally administered MAC address modified from [arg1] to [arg2] by user [arg3]. ()

    This message is for the use case where a user modifies the Ethernet Port MAC address setting.

    May also be shown as 4000000600000000 or 0x4000000600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0006
    User Response
    Information only; no action is required.
  • 40000007-00000000 : Ethernet interface [arg1] by user [arg2]. ()

    This message is for the use case where a user enables or disabled the ethernet interface.

    May also be shown as 4000000700000000 or 0x4000000700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0007
    User Response
    Information only; no action is required.
  • 40000008-00000000 : Hostname set to [arg1] by user [arg2]. ()

    This message is for the use case where user modifies the Hostname of a Management Controller.

    May also be shown as 4000000800000000 or 0x4000000800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - IMM Network event
    SNMP Trap ID
    37
    CIM Information
    Prefix: IMM ID: 0008
    User Response
    Information only; no action is required.
  • 40000009-00000000 : IP address of network interface modified from [arg1] to [arg2] by user [arg3]. ()

    This message is for the use case where user modifies the IP address of a Management Controller.

    May also be shown as 4000000900000000 or 0x4000000900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - IMM Network event
    SNMP Trap ID
    37
    CIM Information
    Prefix: IMM ID: 0009
    User Response
    Information only; no action is required.
  • 4000000a-00000000 : IP subnet mask of network interface modified from [arg1] to [arg2] by user [arg3]. ()

    This message is for the use case where a user modifies the IP subnet mask of a Management Controller.

    May also be shown as 4000000a00000000 or 0x4000000a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0010
    User Response
    Information only; no action is required.
  • 4000000b-00000000 : IP address of default gateway modified from [arg1] to [arg2] by user [arg3]. ()

    This message is for the use case where a user modifies the default gateway IP address of a Management Controller.

    May also be shown as 4000000b00000000 or 0x4000000b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0011
    User Response
    Information only; no action is required.
  • 4000000c-00000000 : OS Watchdog response [arg1] by [arg2] . ()

    This message is for the use case where an OS Watchdog has been enabled or disabled by a user.

    May also be shown as 4000000c00000000 or 0x4000000c00000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0012
    User Response
    Information only; no action is required.
  • 4000000d-00000000 : DHCP[[arg1]] failure, no IP address assigned. ()

    This message is for the use case where a DHCP server fails to assign an IP address to a Management Controller.

    May also be shown as 4000000d00000000 or 0x4000000d00000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0013
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the IMM network cable is connected.
    2. Make sure that there is a DHCP server on the network that can assign an IP address to the IMM.
  • 4000000e-00000000 : Remote Login Successful. Login ID: [arg1] using [arg2] from [arg3] at IP address [arg4]. ()

    This message is for the use case where a user successfully logs in to a Management Controller.

    May also be shown as 4000000e00000000 or 0x4000000e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0014
    User Response
    Information only; no action is required.
  • 4000000f-00000000 : Attempting to [arg1] server [arg2] by user [arg3]. ()

    This message is for the use case where a user is using the Management Controller to perform a power function on the system.

    May also be shown as 4000000f00000000 or 0x4000000f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0015
    User Response
    Information only; no action is required.
  • 40000010-00000000 : Security: Userid: [arg1] using [arg2] had [arg3] login failures from WEB client at IP address [arg4]. ()

    This message is for the use case where a user has failed to log in to a Management Controller from a web browser.

    May also be shown as 4000001000000000 or 0x4000001000000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0016
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the correct login ID and password are being used.
    2. Have the system administrator reset the login ID or password.
  • 40000011-00000000 : Security: Login ID: [arg1] had [arg2] login failures from CLI at [arg3]. ()

    This message is for the use case where a user has failed to log in to a Management Controller from the Legacy CLI.

    May also be shown as 4000001100000000 or 0x4000001100000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0017
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the correct login ID and password are being used.
    2. Have the system administrator reset the login ID or password.
  • 40000012-00000000 : Remote access attempt failed. Invalid userid or password received. Userid is [arg1] from WEB browser at IP address [arg2]. ()

    This message is for the use case where a remote user has failed to establish a remote control session from a Web browser session.

    May also be shown as 4000001200000000 or 0x4000001200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0018
    User Response
    Make sure that the correct login ID and password are being used.
  • 40000013-00000000 : Remote access attempt failed. Invalid userid or password received. Userid is [arg1] from TELNET client at IP address [arg2]. ()

    This message is for the use case where a user has failed to log in to a Management Controller from a telnet session.

    May also be shown as 4000001300000000 or 0x4000001300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0019
    User Response
    Make sure that the correct login ID and password are being used.
  • 40000014-00000000 : The [arg1] on system [arg2] cleared by user [arg3]. ()

    This message is for the use case where a Management Controller Event Log on a system is cleared by a user.

    May also be shown as 4000001400000000 or 0x4000001400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0020
    User Response
    Information only; no action is required.
  • 40000015-00000000 : Management Controller [arg1] reset was initiated by user [arg2]. ()

    This message is for the use case where a Management Controller reset is initiated by a user.

    May also be shown as 4000001500000000 or 0x4000001500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0021
    User Response
    Information only; no action is required.
  • 40000016-00000000 : ENET[[arg1]] DHCP-HSTN=[arg2], DN=[arg3], IP@=[arg4], SN=[arg5], GW@=[arg6], DNS1@=[arg7] . ()

    This message is for the use case where a Management Controller IP address and configuration has been assigned by the DHCP server.

    May also be shown as 4000001600000000 or 0x4000001600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0022
    User Response
    Information only; no action is required.
  • 40000017-00000000 : ENET[[arg1]] IP-Cfg:HstName=[arg2], IP@=[arg3] ,NetMsk=[arg4], GW@=[arg5] . ()

    This message is for the use case where a Management Controller IP address and configuration has been assigned statically using user data.

    May also be shown as 4000001700000000 or 0x4000001700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0023
    User Response
    Information only; no action is required.
  • 40000018-00000000 : LAN: Ethernet[[arg1]] interface is no longer active. ()

    This message is for the use case where a Management Controller ethernet interface is no longer active.

    May also be shown as 4000001800000000 or 0x4000001800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0024
    User Response
    Information only; no action is required.
  • 40000019-00000000 : LAN: Ethernet[[arg1]] interface is now active. ()

    This message is for the use case where a Management Controller ethernet interface is now active.

    May also be shown as 4000001900000000 or 0x4000001900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0025
    User Response
    Information only; no action is required.
  • 4000001a-00000000 : DHCP setting changed to [arg1] by user [arg2]. ()

    This message is for the use case where a user changes the DHCP setting.

    May also be shown as 4000001a00000000 or 0x4000001a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0026
    User Response
    Information only; no action is required.
  • 4000001b-00000000 : Management Controller [arg1]: Configuration restored from a file by user [arg2]. ()

    This message is for the use case where a user restores a Management Controller configuration from a file.

    May also be shown as 4000001b00000000 or 0x4000001b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0027
    User Response
    Information only; no action is required.
  • 4000001c-00000000 : Watchdog [arg1] Screen Capture Occurred . ()

    This message is for the use case where an operating system error has occurred and the screen was captured.

    May also be shown as 4000001c00000000 or 0x4000001c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0028
    User Response
    If there was no operating-system error, complete the following steps until the problem is solved:
    1. Reconfigure the watchdog timer to a higher value.
    2. Make sure that the IMM Ethernet-over-USB interface is enabled.
    3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
    4. Disable the watchdog.
    If there was an operating-system error, check the integrity of the installed operating system.
  • 4000001d-00000000 : Watchdog [arg1] Failed to Capture Screen. ()

    This message is for the use case where an operating system error has occurred and the screen capture failed.

    May also be shown as 4000001d00000000 or 0x4000001d00000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0029
    User Response
    Complete the following steps until the problem is solved:
    1. Reconfigure the watchdog timer to a higher value.
    2. Make sure that the IMM Ethernet over USB interface is enabled.
    3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
    4. Disable the watchdog. Check the integrity of the installed operating system.
    5. Update the IMM firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
  • 4000001e-00000000 : Running the backup Management Controller [arg1] main application. ()

    This message is for the use case where a Management Controller has resorted to running the backup main application.

    May also be shown as 4000001e00000000 or 0x4000001e00000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0030
    User Response
    Update the IMM firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
  • 4000001f-00000000 : Please ensure that the Management Controller [arg1] is flashed with the correct firmware. The Management Controller is unable to match its firmware to the server. ()

    This message is for the use case where a Management Controller firmware version does not match the server.

    May also be shown as 4000001f00000000 or 0x4000001f00000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0031
    User Response
    Update the IMM firmware to a version that the server supports. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
  • 40000020-00000000 : Management Controller [arg1] Reset was caused by restoring default values. ()

    This message is for the use case where a Management Controller has been reset due to a user restoring the configuration to default values.

    May also be shown as 4000002000000000 or 0x4000002000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0032
    User Response
    Information only; no action is required.
  • 40000021-00000000 : Management Controller [arg1] clock has been set from NTP server [arg2]. ()

    This message is for the use case where a Management Controller clock has been set from the Network Time Protocol server.

    May also be shown as 4000002100000000 or 0x4000002100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0033
    User Response
    Information only; no action is required.
  • 40000022-00000000 : SSL data in the Management Controller [arg1] configuruation data is invalid. Clearing configuration data region and disabling SSL. ()

    This message is for the use case where a Management Controller has detected invalid SSL data in the configuration data and is clearing the configuration data region and disabling the SSL.

    May also be shown as 4000002200000000 or 0x4000002200000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0034
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the certificate that you are importing is correct.
    2. Try to import the certificate again.
  • 40000023-00000000 : Flash of [arg1] from [arg2] succeeded for user [arg3] . ()

    This message is for the use case where a user has successfully flashed the firmware component (MC Main Application, MC Boot ROM, BIOS, Diagnostics, System Power Backplane, Remote Expansion Enclosure Power Backplane, Integrated System Managem

    May also be shown as 4000002300000000 or 0x4000002300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0035
    User Response
    Information only; no action is required.
  • 40000024-00000000 : Flash of [arg1] from [arg2] failed for user [arg3]. ()

    This message is for the use case where a user has not flashed the firmware component from the interface and IP address due to a failure.

    May also be shown as 4000002400000000 or 0x4000002400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0036
    User Response
    Information only; no action is required.
  • 40000025-00000000 : The [arg1] on system [arg2] is 75% full. ()

    This message is for the use case where a Management Controller Event Log on a system is 75% full.

    May also be shown as 4000002500000000 or 0x4000002500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Event Log 75% full
    SNMP Trap ID
    35
    CIM Information
    Prefix: IMM ID: 0037
    User Response
    Information only; no action is required.
  • 40000026-00000000 : The [arg1] on system [arg2] is 100% full. ()

    This message is for the use case where a Management Controller Event Log on a system is 100% full.

    May also be shown as 4000002600000000 or 0x4000002600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Event Log 75% full
    SNMP Trap ID
    35
    CIM Information
    Prefix: IMM ID: 0038
    User Response
    To avoid losing older log entries, save the log as a text file and clear the log.
  • 40000027-00000000 : Platform Watchdog Timer expired for [arg1]. ()

    This message is for the use case when an implementation has detected a Platform Watchdog Timer Expired

    May also be shown as 4000002700000000 or 0x4000002700000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - OS Timeout
    SNMP Trap ID
    21
    CIM Information
    Prefix: IMM ID: 0039
    User Response
    Complete the following steps until the problem is solved:
    1. Reconfigure the watchdog timer to a higher value.
    2. Make sure that the IMM Ethernet-over-USB interface is enabled.
    3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
    4. Disable the watchdog.
    5. Check the integrity of the installed operating system.
  • 40000028-00000000 : Management Controller Test Alert Generated by [arg1]. ()

    This message is for the use case where a user has generated a Test Alert.

    May also be shown as 4000002800000000 or 0x4000002800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0040
    User Response
    Information only; no action is required.
  • 40000029-00000000 : Security: Userid: [arg1] using [arg2] had [arg3] login failures from an SSH client at IP address [arg4]. ()

    This message is for the use case where a user has failed to log in to a Management Controller from SSH.

    May also be shown as 4000002900000000 or 0x4000002900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0041
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the correct login ID and password are being used.
    2. Have the system administrator reset the login ID or password.
  • 4000002a-00000000 : [arg1] firmware mismatch internal to system [arg2]. Please attempt to flash the [arg3] firmware. ()

    This message is for the use case where a specific type of firmware mismatch has been detected.

    May also be shown as 4000002a00000000 or 0x4000002a00000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0042
    User Response
    Reflash the IMM firmware to the latest version.
  • 4000002b-00000000 : Domain name set to [arg1]. ()

    Domain name set by user

    May also be shown as 4000002b00000000 or 0x4000002b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0043
    User Response
    Information only; no action is required.
  • 4000002c-00000000 : Domain Source changed to [arg1] by user [arg2]. ()

    Domain source changed by user

    May also be shown as 4000002c00000000 or 0x4000002c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0044
    User Response
    Information only; no action is required.
  • 4000002d-00000000 : DDNS setting changed to [arg1] by user [arg2]. ()

    DDNS setting changed by user

    May also be shown as 4000002d00000000 or 0x4000002d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0045
    User Response
    Information only; no action is required.
  • 4000002e-00000000 : DDNS registration successful. The domain name is [arg1]. ()

    DDNS registation and values

    May also be shown as 4000002e00000000 or 0x4000002e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0046
    User Response
    Information only; no action is required.
  • 4000002f-00000000 : IPv6 enabled by user [arg1] . ()

    IPv6 protocol is enabled by user

    May also be shown as 4000002f00000000 or 0x4000002f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0047
    User Response
    Information only; no action is required.
  • 40000030-00000000 : IPv6 disabled by user [arg1] . ()

    IPv6 protocol is disabled by user

    May also be shown as 4000003000000000 or 0x4000003000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0048
    User Response
    Information only; no action is required.
  • 40000031-00000000 : IPv6 static IP configuration enabled by user [arg1]. ()

    IPv6 static address assignment method is enabled by user

    May also be shown as 4000003100000000 or 0x4000003100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0049
    User Response
    Information only; no action is required.
  • 40000032-00000000 : IPv6 DHCP enabled by user [arg1]. ()

    IPv6 DHCP assignment method is enabled by user

    May also be shown as 4000003200000000 or 0x4000003200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0050
    User Response
    Information only; no action is required.
  • 40000033-00000000 : IPv6 stateless auto-configuration enabled by user [arg1]. ()

    IPv6 statless auto-assignment method is enabled by user

    May also be shown as 4000003300000000 or 0x4000003300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0051
    User Response
    Information only; no action is required.
  • 40000034-00000000 : IPv6 static IP configuration disabled by user [arg1]. ()

    IPv6 static assignment method is disabled by user

    May also be shown as 4000003400000000 or 0x4000003400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0052
    User Response
    Information only; no action is required.
  • 40000035-00000000 : IPv6 DHCP disabled by user [arg1]. ()

    IPv6 DHCP assignment method is disabled by user

    May also be shown as 4000003500000000 or 0x4000003500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0053
    User Response
    Information only; no action is required.
  • 40000036-00000000 : IPv6 stateless auto-configuration disabled by user [arg1]. ()

    IPv6 statless auto-assignment method is disabled by user

    May also be shown as 4000003600000000 or 0x4000003600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0054
    User Response
    Information only; no action is required.
  • 40000037-00000000 : ENET[[arg1]] IPv6-LinkLocal:HstName=[arg2], IP@=[arg3] ,Pref=[arg4] . ()

    IPv6 Link Local address is active

    May also be shown as 4000003700000000 or 0x4000003700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0055
    User Response
    Information only; no action is required.
  • 40000038-00000000 : ENET[[arg1]] IPv6-Static:HstName=[arg2], IP@=[arg3] ,Pref=[arg4], GW@=[arg5] . ()

    IPv6 Static address is active

    May also be shown as 4000003800000000 or 0x4000003800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0056
    User Response
    Information only; no action is required.
  • 40000039-00000000 : ENET[[arg1]] DHCPv6-HSTN=[arg2], DN=[arg3], IP@=[arg4], Pref=[arg5]. ()

    IPv6 DHCP-assigned address is active

    May also be shown as 4000003900000000 or 0x4000003900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0057
    User Response
    Information only; no action is required.
  • 4000003a-00000000 : IPv6 static address of network interface modified from [arg1] to [arg2] by user [arg3]. ()

    A user modifies the IPv6 static address of a Management Controller

    May also be shown as 4000003a00000000 or 0x4000003a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0058
    User Response
    Information only; no action is required.
  • 4000003b-00000000 : DHCPv6 failure, no IP address assigned. ()

    S DHCP6 server fails to assign an IP address to a Management Controller.

    May also be shown as 4000003b00000000 or 0x4000003b00000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0059
    User Response
    Complete the following steps until the problem is solved:
    1. Make sure that the IMM network cable is connected.
    2. Make sure that there is a DHCPv6 server on the network that can assign an IP address to the IMM.
  • 4000003c-00000000 : Platform Watchdog Timer expired for [arg1]. ()

    An implementation has detected an OS Loader Watchdog Timer Expired

    May also be shown as 4000003c00000000 or 0x4000003c00000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Loader timeout
    SNMP Trap ID
    26
    CIM Information
    Prefix: IMM ID: 0060
    User Response
    1. Reconfigure the watchdog timer to a higher value.
    2. Make sure that the IMM Ethernet over USB interface is enabled.
    3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
    4. Disable the watchdog.
    5. Check the integrity of the installed operating system.
  • 4000003d-00000000 : Telnet port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the telnet port number

    May also be shown as 4000003d00000000 or 0x4000003d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0061
    User Response
    Information only; no action is required.
  • 4000003e-00000000 : SSH port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the SSH port number

    May also be shown as 4000003e00000000 or 0x4000003e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0062
    User Response
    Information only; no action is required.
  • 4000003f-00000000 : Web-HTTP port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the Web HTTP port number

    May also be shown as 4000003f00000000 or 0x4000003f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0063
    User Response
    Information only; no action is required.
  • 40000040-00000000 : Web-HTTPS port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the Web HTTPS port number

    May also be shown as 4000004000000000 or 0x4000004000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0064
    User Response
    Information only; no action is required.
  • 40000041-00000000 : CIM/XML HTTP port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the CIM HTTP port number

    May also be shown as 4000004100000000 or 0x4000004100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0065
    User Response
    Information only; no action is required.
  • 40000042-00000000 : CIM/XML HTTPS port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the CIM HTTPS port number

    May also be shown as 4000004200000000 or 0x4000004200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0066
    User Response
    Information only; no action is required.
  • 40000043-00000000 : SNMP Agent port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the SNMP Agent port number

    May also be shown as 4000004300000000 or 0x4000004300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0067
    User Response
    Information only; no action is required.
  • 40000044-00000000 : SNMP Traps port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the SNMP Traps port number

    May also be shown as 4000004400000000 or 0x4000004400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0068
    User Response
    Information only; no action is required.
  • 40000045-00000000 : Syslog port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the Syslog receiver port number

    May also be shown as 4000004500000000 or 0x4000004500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0069
    User Response
    Information only; no action is required.
  • 40000046-00000000 : Remote Presence port number changed from [arg1] to [arg2] by user [arg3]. ()

    A user has modified the Remote Presence port number

    May also be shown as 4000004600000000 or 0x4000004600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0070
    User Response
    Information only; no action is required.
  • 40000047-00000000 : LED [arg1] state changed to [arg2] by [arg3]. ()

    A user has modified the state of an LED

    May also be shown as 4000004700000000 or 0x4000004700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0071
    User Response
    Information only; no action is required.
  • 40000048-00000000 : Inventory data changed for device [arg1], new device data hash=[arg2], new master data hash=[arg3] . ()

    Something has caused the physical inventory to change

    May also be shown as 4000004800000000 or 0x4000004800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0072
    User Response
    Information only; no action is required.
  • 40000049-00000000 : SNMP [arg1] enabled by user [arg2] . ()

    A user enabled SNMPv1 or SNMPv3 or Traps

    May also be shown as 4000004900000000 or 0x4000004900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0073
    User Response
    Information only; no action is required.
  • 4000004a-00000000 : SNMP [arg1] disabled by user [arg2] . ()

    A user disabled SNMPv1 or SNMPv3 or Traps

    May also be shown as 4000004a00000000 or 0x4000004a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0074
    User Response
    Information only; no action is required.
  • 4000004b-00000000 : SNMPv1 [arg1] set by user [arg2]: Name=[arg3], AccessType=[arg4], Address=[arg5], . ()

    A user changed the SNMP community string

    May also be shown as 4000004b00000000 or 0x4000004b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0075
    User Response
    Information only; no action is required.
  • 4000004c-00000000 : LDAP Server configuration set by user [arg1]: SelectionMethod=[arg2], DomainName=[arg3], Server1=[arg4], Server2=[arg5], Server3=[arg6], Server4=[arg7]. ()

    A user changed the LDAP server configuration

    May also be shown as 4000004c00000000 or 0x4000004c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0076
    User Response
    Information only; no action is required.
  • 4000004d-00000000 : LDAP set by user [arg1]: RootDN=[arg2], UIDSearchAttribute=[arg3], BindingMethod=[arg4], EnhancedRBS=[arg5], TargetName=[arg6], GroupFilter=[arg7], GroupAttribute=[arg8], LoginAttribute=[arg9]. ()

    A user configured an LDAP Miscellaneous setting

    May also be shown as 4000004d00000000 or 0x4000004d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0077
    User Response
    Information only; no action is required.
  • 4000004e-00000000 : Serial Redirection set by user [arg1]: Mode=[arg2], BaudRate=[arg3], StopBits=[arg4], Parity=[arg5], SessionTerminateSequence=[arg6]. ()

    A user configured the Serial Port mode

    May also be shown as 4000004e00000000 or 0x4000004e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0078
    User Response
    Information only; no action is required.
  • 4000004f-00000000 : Date and Time set by user [arg1]: Date=[arg2], Time-[arg3], DST Auto-adjust=[arg4], Timezone=[arg5]. ()

    A user configured the Date and Time settings

    May also be shown as 4000004f00000000 or 0x4000004f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0079
    User Response
    Information only; no action is required.
  • 40000050-00000000 : Server General Settings set by user [arg1]: Name=[arg2], Contact=[arg3], Location=[arg4], Room=[arg5], RackID=[arg6], Rack U-position=[arg7]. ()

    A user configured the Location setting

    May also be shown as 4000005000000000 or 0x4000005000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0080
    User Response
    Information only; no action is required.
  • 40000051-00000000 : Server Power Off Delay set to [arg1] by user [arg2]. ()

    A user configured the Server Power Off Delay

    May also be shown as 4000005100000000 or 0x4000005100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0081
    User Response
    Information only; no action is required.
  • 40000052-00000000 : Server [arg1] scheduled for [arg2] at [arg3] by user [arg4]. ()

    A user configured a Server Power action at a specific time

    May also be shown as 4000005200000000 or 0x4000005200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0082
    User Response
    Information only; no action is required.
  • 40000053-00000000 : Server [arg1] scheduled for every [arg2] at [arg3] by user [arg4]. ()

    A user configured a recurring Server Power Action

    May also be shown as 4000005300000000 or 0x4000005300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0083
    User Response
    Information only; no action is required.
  • 40000054-00000000 : Server [arg1] [arg2] cleared by user [arg3]. ()

    A user cleared a Server Power Action.

    May also be shown as 4000005400000000 or 0x4000005400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0084
    User Response
    Information only; no action is required.
  • 40000055-00000000 : Synchronize time setting by user [arg1]: Mode=[arg2], NTPServerHost1=[arg3]:[arg4],NTPServerHost2=[arg5]:[arg6],NTPServerHost3=[arg7]:[arg8],NTPServerHost4=[arg9]:[arg10],NTPUpdateFrequency=[arg11]. ()

    A user configured the Date and Time synchronize settings

    May also be shown as 4000005500000000 or 0x4000005500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0085
    User Response
    Information only; no action is required.
  • 40000056-00000000 : SMTP Server set by user [arg1] to [arg2]:[arg3]. ()

    A user configured the SMTP server

    May also be shown as 4000005600000000 or 0x4000005600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0086
    User Response
    Information only; no action is required.
  • 40000057-00000000 : Telnet [arg1] by user [arg2]. ()

    A user enables or disables Telnet services

    May also be shown as 4000005700000000 or 0x4000005700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0087
    User Response
    Information only; no action is required.
  • 40000058-00000000 : DNS servers set by user [arg1]: UseAdditionalServers=[arg2], PreferredDNStype=[arg3], IPv4Server1=[arg4], IPv4Server2=[arg5], IPv4Server3=[arg6], IPv6Server1=[arg7], IPv6Server2=[arg8], IPv6Server3=[arg9]. ()

    A user configures the DNS servers

    May also be shown as 4000005800000000 or 0x4000005800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0088
    User Response
    Information only; no action is required.
  • 40000059-00000000 : LAN over USB [arg1] by user [arg2]. ()

    A user configured USB-LAN

    May also be shown as 4000005900000000 or 0x4000005900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0089
    User Response
    Information only; no action is required.
  • 4000005a-00000000 : LAN over USB Port Forwarding set by user [arg1]: ExternalPort=[arg2], USB-LAN port=[arg3]. ()

    A user configured USB-LAN port forwarding

    May also be shown as 4000005a00000000 or 0x4000005a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0090
    User Response
    Information only; no action is required.
  • 4000005b-00000000 : Secure Web services (HTTPS) [arg1] by user [arg2]. ()

    A user enables or disables Secure web services

    May also be shown as 4000005b00000000 or 0x4000005b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0091
    User Response
    Information only; no action is required.
  • 4000005c-00000000 : Secure CIM/XML(HTTPS) [arg1] by user [arg2]. ()

    A user enables or disables Secure CIM/XML services

    May also be shown as 4000005c00000000 or 0x4000005c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0092
    User Response
    Information only; no action is required.
  • 4000005d-00000000 : Secure LDAP [arg1] by user [arg2]. ()

    A user enables or disables Secure LDAP services

    May also be shown as 4000005d00000000 or 0x4000005d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0093
    User Response
    Information only; no action is required.
  • 4000005e-00000000 : SSH [arg1] by user [arg2]. ()

    A user enables or disables SSH services

    May also be shown as 4000005e00000000 or 0x4000005e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0094
    User Response
    Information only; no action is required.
  • 4000005f-00000000 : Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2], OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4], LoaderTimeout=[arg5]. ()

    A user configures Server Timeouts

    May also be shown as 4000005f00000000 or 0x4000005f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0095
    User Response
    Information only; no action is required.
  • 40000060-00000000 : License key for [arg1] added by user [arg2]. ()

    A user installs License Key

    May also be shown as 4000006000000000 or 0x4000006000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0096
    User Response
    Information only; no action is required.
  • 40000061-00000000 : License key for [arg1] removed by user [arg2]. ()

    A user removes a License Key

    May also be shown as 4000006100000000 or 0x4000006100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0097
    User Response
    Information only; no action is required.
  • 40000062-00000000 : Global Login General Settings set by user [arg1]: AuthenticationMethod=[arg2], LockoutPeriod=[arg3], SessionTimeout=[arg4]. ()

    A user changes the Global Login General Settings

    May also be shown as 4000006200000000 or 0x4000006200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0098
    User Response
    Information only; no action is required.
  • 40000063-00000000 : Global Login Account Security set by user [arg1]: PasswordRequired=[arg2], PasswordExpirationPeriod=[arg3], MinimumPasswordReuseCycle=[arg4], MinimumPasswordLength=[arg5], MinimumPasswordChangeInterval=[arg6], MaxmumLoginFailures=[arg7], LockoutAfterMaxFailures=[arg8]. ()

    A user changes the Global Login Account Security Settings to Legacy

    May also be shown as 4000006300000000 or 0x4000006300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0099
    User Response
    Information only; no action is required.
  • 40000064-00000000 : User [arg1] created. ()

    A user account was created

    May also be shown as 4000006400000000 or 0x4000006400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0100
    User Response
    Information only; no action is required.
  • 40000065-00000000 : User [arg1] removed. ()

    A user account was deleted

    May also be shown as 4000006500000000 or 0x4000006500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0101
    User Response
    Information only; no action is required.
  • 40000066-00000000 : User [arg1] password modified. ()

    A user account was changed

    May also be shown as 4000006600000000 or 0x4000006600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0102
    User Response
    Information only; no action is required.
  • 40000067-00000000 : User [arg1] role set to [arg2]. ()

    A user account role assigned

    May also be shown as 4000006700000000 or 0x4000006700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0103
    User Response
    Information only; no action is required.
  • 40000068-00000000 : User [arg1] custom privileges set: [arg2]. ()

    User account priveleges assigned

    May also be shown as 4000006800000000 or 0x4000006800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0104
    User Response
    Information only; no action is required.
  • 40000069-00000000 : User [arg1] for SNMPv3 set: AuthenticationProtocol=[arg2], PrivacyProtocol=[arg3], AccessType=[arg4], HostforTraps=[arg5]. ()

    User account SNMPv3 settings changed

    May also be shown as 4000006900000000 or 0x4000006900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0105
    User Response
    Information only; no action is required.
  • 4000006a-00000000 : SSH Client key added for user [arg1]. ()

    User locally defined an SSH Client key

    May also be shown as 4000006a00000000 or 0x4000006a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0106
    User Response
    Information only; no action is required.
  • 4000006b-00000000 : SSH Client key imported for user [arg1] from [arg2]. ()

    User imported an SSH Client key

    May also be shown as 4000006b00000000 or 0x4000006b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0107
    User Response
    Information only; no action is required.
  • 4000006c-00000000 : SSH Client key removed from user [arg1]. ()

    User removed an SSH Client key

    May also be shown as 4000006c00000000 or 0x4000006c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0108
    User Response
    Information only; no action is required.
  • 4000006d-00000000 : Management Controller [arg1]: Configuration saved to a file by user [arg2]. ()

    A user saves a Management Controller configuration to a file.

    May also be shown as 4000006d00000000 or 0x4000006d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0109
    User Response
    Information only; no action is required.
  • 4000006e-00000000 : Alert Configuration Global Event Notification set by user [arg1]: RetryLimit=[arg2], RetryInterval=[arg3], EntryInterval=[arg4]. ()

    A user changes the Global Event Notification settings.

    May also be shown as 4000006e00000000 or 0x4000006e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0110
    User Response
    Information only; no action is required.
  • 4000006f-00000000 : Alert Recipient Number [arg1] updated: Name=[arg2], DeliveryMethod=[arg3], Address=[arg4], IncludeLog=[arg5], Enabled=[arg6], EnabledAlerts=[arg7], AllowedFilters=[arg8]. ()

    A user adds or updates an Alert Recipient

    May also be shown as 4000006f00000000 or 0x4000006f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0111
    User Response
    Information only; no action is required.
  • 40000070-00000000 : SNMP Traps enabled by user [arg1]: EnabledAlerts=[arg2], AllowedFilters=[arg3] . ()

    A user enabled the SNMP Traps configuration

    May also be shown as 4000007000000000 or 0x4000007000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0112
    User Response
    Information only; no action is required.
  • 40000071-00000000 : The power cap value changed from [arg1] watts to [arg2] watts by user [arg3]. ()

    Power Cap values changed by user

    May also be shown as 4000007100000000 or 0x4000007100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0113
    User Response
    Information only; no action is required.
  • 40000072-00000000 : The minimum power cap value changed from [arg1] watts to [arg2] watts. ()

    Minimum Power Cap value changed

    May also be shown as 4000007200000000 or 0x4000007200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0114
    User Response
    Information only; no action is required.
  • 40000073-00000000 : The maximum power cap value changed from [arg1] watts to [arg2] watts. ()

    Maximum Power Cap value changed

    May also be shown as 4000007300000000 or 0x4000007300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0115
    User Response
    Information only; no action is required.
  • 40000074-00000000 : The soft minimum power cap value changed from [arg1] watts to [arg2] watts. ()

    Soft Minimum Power Cap value changed

    May also be shown as 4000007400000000 or 0x4000007400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0116
    User Response
    Information only; no action is required.
  • 40000075-00000000 : The measured power value exceeded the power cap value. ()

    Power exceeded cap

    May also be shown as 4000007500000000 or 0x4000007500000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Power
    SNMP Trap ID
    164
    CIM Information
    Prefix: IMM ID: 0117
    User Response
    Information only; no action is required.
  • 40000076-00000000 : The new minimum power cap value exceeded the power cap value. ()

    Minimum Power Cap exceeds Power Cap

    May also be shown as 4000007600000000 or 0x4000007600000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Power
    SNMP Trap ID
    164
    CIM Information
    Prefix: IMM ID: 0118
    User Response
    Information only; no action is required.
  • 40000077-00000000 : Power capping was activated by user [arg1]. ()

    Power capping activated by user

    May also be shown as 4000007700000000 or 0x4000007700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0119
    User Response
    Information only; no action is required.
  • 40000078-00000000 : Power capping was deactivated by user [arg1]. ()

    Power capping deactivated by user

    May also be shown as 4000007800000000 or 0x4000007800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0120
    User Response
    Information only; no action is required.
  • 40000079-00000000 : Static Power Savings mode has been turned on by user [arg1]. ()

    Static Power Savings mode turned on by user

    May also be shown as 4000007900000000 or 0x4000007900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0121
    User Response
    Information only; no action is required.
  • 4000007a-00000000 : Static Power Savings mode has been turned off by user [arg1]. ()

    Static Power Savings mode turned off by user

    May also be shown as 4000007a00000000 or 0x4000007a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0122
    User Response
    Information only; no action is required.
  • 4000007b-00000000 : Dynamic Power Savings mode has been turned on by user [arg1]. ()

    Dynamic Power Savings mode turned on by user

    May also be shown as 4000007b00000000 or 0x4000007b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0123
    User Response
    Information only; no action is required.
  • 4000007c-00000000 : Dynamic Power Savings mode has been turned off by user [arg1]. ()

    Dynamic Power Savings mode turned off by user

    May also be shown as 4000007c00000000 or 0x4000007c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0124
    User Response
    Information only; no action is required.
  • 4000007d-00000000 : Power cap and external throttling occurred. ()

    Power cap and external throttling occurred

    May also be shown as 4000007d00000000 or 0x4000007d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0125
    User Response
    Information only; no action is required.
  • 4000007e-00000000 : External throttling occurred . ()

    External throttling occurred

    May also be shown as 4000007e00000000 or 0x4000007e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0126
    User Response
    Information only; no action is required.
  • 4000007f-00000000 : Power cap throttling occurred. ()

    Power cap throttling occurrred

    May also be shown as 4000007f00000000 or 0x4000007f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0127
    User Response
    Information only; no action is required.
  • 40000080-00000000 : Remote Control session started by user [arg1] in [arg2] mode. ()

    Remote Control session started

    May also be shown as 4000008000000000 or 0x4000008000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0128
    User Response
    Information only; no action is required.
  • 40000081-00000000 : PXE boot requested by user [arg1]. ()

    PXE boot requested

    May also be shown as 4000008100000000 or 0x4000008100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0129
    User Response
    Information only; no action is required.
  • 40000082-00000000 : The measured power value has returned below the power cap value. ()

    Power exceeded cap recovered

    May also be shown as 4000008200000000 or 0x4000008200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Power
    SNMP Trap ID
    164
    CIM Information
    Prefix: IMM ID: 0130
    User Response
    Information only; no action is required.
  • 40000083-00000000 : The new minimum power cap value has returned below the power cap value. ()

    Minimum Power Cap exceeds Power Cap recovered

    May also be shown as 4000008300000000 or 0x4000008300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Power
    SNMP Trap ID
    164
    CIM Information
    Prefix: IMM ID: 0131
    User Response
    Information only; no action is required.
  • 40000084-00000000 : IMM firmware mismatch between nodes [arg1] and [arg2]. Please attempt to flash the IMM firmware to the same level on all nodes. ()

    A mismatch of IMM firmware has been detected between nodes

    May also be shown as 4000008400000000 or 0x4000008400000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0132
    User Response
    Attempt to flash the IMM firmware to the same level on all nodes.
  • 40000085-00000000 : FPGA firmware mismatch between nodes [arg1] and [arg2]. Please attempt to flash the FPGA firmware to the same level on all nodes. ()

    A mismatch of FPGA firmware has been detected between nodes

    May also be shown as 4000008500000000 or 0x4000008500000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0133
    User Response
    Attempt to flash the FPGA firmware to the same level on all nodes.
  • 40000086-00000000 : Test Call Home Generated by user [arg1]. ()

    Test Call Home generated by user.

    May also be shown as 4000008600000000 or 0x4000008600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    Yes
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0134
    User Response
    Information only; no action is required.
  • 40000087-00000000 : Manual Call Home by user [arg1]: [arg2]. ()

    Manual Call Home by user.

    May also be shown as 4000008700000000 or 0x4000008700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    Yes
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0135
    User Response
    IBM Support will address the problem.
  • 40000088-00000000 : Management Controller [arg1]: Configuration restoration from a file by user [arg2] completed. ()

    This message is for the use case where a user restores a Management Controller configuration from a file and it completes.

    May also be shown as 4000008800000000 or 0x4000008800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0136
    User Response
    Information only; no action is required.
  • 40000089-00000000 : Management Controller [arg1]: Configuration restoration from a file by user [arg2] failed to complete. ()

    This message is for the use case where a user restores a Management Controller configuration from a file and the restoration fails to complete.

    May also be shown as 4000008900000000 or 0x4000008900000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0137
    User Response
    1. Turn off the server and disconnect it from the power source. You must disconnect the server from ac power to reset the IMM.
    2. After 45 seconds, reconnect the server to the power source and turn on the server.
    3. Retry the operation.
  • 4000008a-00000000 : Management Controller [arg1]: Configuration restoration from a file by user [arg2] failed to start. ()

    This message is for the use case where a user restores a Management Controller configuration from a file and the restoration fails to start.

    May also be shown as 4000008a00000000 or 0x4000008a00000000

    Severity
    Error
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0138
    User Response
    1. Turn off the server and disconnect it from the power source. You must disconnect the server from ac power to reset the IMM.
    2. After 45 seconds, reconnect the server to the power source and turn on the server.
    3. Retry the operation.
  • 4000008b-00000000 : Storage [arg1] has changed. ()

    This message is for the use case where an IP address for the Storage Management has changed

    May also be shown as 4000008b00000000 or 0x4000008b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - IMM Network event
    SNMP Trap ID
    37
    CIM Information
    Prefix: IMM ID: 0139
    User Response
    Information only; no action is required.
  • 4000008c-00000000 : Security: Userid: [arg1] had [arg2] login failures from a CIM client at IP address [arg3]. ()

    This message is for the use case where a user has failed to log in to a Management Controller from CIM.

    May also be shown as 4000008c00000000 or 0x4000008c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0140
    User Response
    Information only; no action is required.
  • 4000008d-00000000 : Remote access attempt failed. Invalid userid or password received. Userid is [arg1] from a CIM client at IP address [arg2]. ()

    This message is for the use case where a remote user has failed to establish a remote control session from CIM.

    May also be shown as 4000008d00000000 or 0x4000008d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0141
    User Response
    Information only; no action is required.
  • 4000008e-00000000 : Device [arg1] VPD is not valid. ()

    The VPD for a device is invalid

    May also be shown as 4000008e00000000 or 0x4000008e00000000

    Severity
    Warning
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0142
    User Response
    Information only; no action is required.
  • 4000008f-00000000 : The bare metal connection process has been started. ()

    Bare Metal Connection process has been started

    May also be shown as 4000008f00000000 or 0x4000008f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0143
    User Response
    Information only; no action is required.
  • 40000090-00000000 : The bare metal update application reports a status of [arg1]. ()

    Bare Metal Update Application Status

    May also be shown as 4000009000000000 or 0x4000009000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0144
    User Response
    Information only; no action is required.
  • 40000091-00000000 : User [arg1] has terminated an active console session. ()

    A user has terminated an active console session

    May also be shown as 4000009100000000 or 0x4000009100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0145
    User Response
    Information only; no action is required.
  • 40000092-00000000 : TKLM servers set by user [arg1]: TKLMServer1=[arg2] Port=[arg3], TKLMServer2=[arg4] Port=[arg5], TKLMServer3=[arg6] Port=[arg7], TKLMServer4=[arg8] Port=[arg9]. ()

    A user configured the TKLM servers

    May also be shown as 4000009200000000 or 0x4000009200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0146
    User Response
    Information only; no action is required.
  • 40000093-00000000 : TKLM servers device group set by user [arg1]: TKLMServerDeviceGroup=[arg2] . ()

    A user configured the TKLM device group

    May also be shown as 4000009300000000 or 0x4000009300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0147
    User Response
    Information only; no action is required.
  • 40000094-00000000 : User [arg1] has generated a new encryption key pair and installed a self-signed certificate for the TKLM client. ()

    User generated a new encryption key pair and installed a self-signed certificate for the TKLM client

    May also be shown as 4000009400000000 or 0x4000009400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0148
    User Response
    Information only; no action is required.
  • 40000095-00000000 : User [arg1] has generated a new encryption key and certificate signing request for the TKLM client. ()

    User generated a new encryption key and certificate signing request for the TKLM client

    May also be shown as 4000009500000000 or 0x4000009500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0149
    User Response
    Information only; no action is required.
  • 40000096-00000000 : User [arg1] has imported a signed certificate for the TKLM client from [arg2]. ()

    User imported a signed certificate for the TKLM client

    May also be shown as 4000009600000000 or 0x4000009600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0150
    User Response
    Information only; no action is required.
  • 40000097-00000000 : User [arg1] has imported a server certificate for the TKLM server. ()

    User imported a server certificate for the TKLM Server

    May also be shown as 4000009700000000 or 0x4000009700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0151
    User Response
    Information only; no action is required.
  • 40000098-00000000 : The UEFI Definitions have been changed. ()

    UEFI Definitions change has been detected

    May also be shown as 4000009800000000 or 0x4000009800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0152
    User Response
    Information only; no action is required.
  • 40000099-00000000 : Security: Userid: [arg1] had [arg2] login failures from IPMI client at IP address [arg3]. ()

    This message is for the use case where a user has failed to log in to a Management Controller from IPMI.

    May also be shown as 4000009900000000 or 0x4000009900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0153
    User Response
    Information only; no action is required.
  • 4000009a-00000000 : Security: Userid: [arg1] had [arg2] login failures from SNMP client at IP address [arg3]. ()

    This message is for the use case where a user has failed to access a Management Controller from SNMP.

    May also be shown as 4000009a00000000 or 0x4000009a00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0154
    User Response
    Information only; no action is required.
  • 4000009b-00000000 : Security: Userid: [arg1] had [arg2] login failures from IPMI serial client. ()

    This message is for the use case where a user has failed to log in to a Management Controller from IPMI serial client

    May also be shown as 4000009b00000000 or 0x4000009b00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0155
    User Response
    Information only; no action is required.
  • 4000009c-00000000 : Remote Login Successful. Login ID: [arg1] from [arg2] serial interface. ()

    This message is for the use case where a user successfully logs in to a Management Controller.

    May also be shown as 4000009c00000000 or 0x4000009c00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0156
    User Response
    Information only; no action is required.
  • 4000009d-00000000 : Login ID: [arg1] from [arg2] at IP address [arg3] has logged off. ()

    This message is for the use case where a user has logged off of a Management Controller.

    May also be shown as 4000009d00000000 or 0x4000009d00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0157
    User Response
    Information only; no action is required.
  • 4000009e-00000000 : Login ID: [arg1] from [arg2] at IP address [arg3] has been logged off. ()

    This message is for the use case where a user has been logged off of a Management Controller.

    May also be shown as 4000009e00000000 or 0x4000009e00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Remote Login
    SNMP Trap ID
    30
    CIM Information
    Prefix: IMM ID: 0158
    User Response
    Information only; no action is required.
  • 4000009f-00000000 : User [arg1] has initiated a TKLM Server Connection Test to check connectivity to server [arg2]. ()

    User initiated a TKLM Server Connection test.

    May also be shown as 4000009f00000000 or 0x4000009f00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0159
    User Response
    Information only; no action is required.
  • 400000a0-00000000 : User [arg1] has initiated an SMTP Server Connection Test. ()

    User initiated an SMTP Server Connection test.

    May also be shown as 400000a000000000 or 0x400000a000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0160
    User Response
    Information only; no action is required.
  • 400000a1-00000000 : UEFI Reported: [arg1]. ()

    UEFI audit event logged.

    May also be shown as 400000a100000000 or 0x400000a100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0161
    User Response
    Information only; no action is required.
  • 400000a2-00000000 : User [arg1] has [arg2] file [arg3] from [arg4]. ()

    User has mounted/unmounted file from URL or server

    May also be shown as 400000a200000000 or 0x400000a200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0162
    User Response
    Information only; no action is required.
  • 400000a3-00000000 : User [arg1] has set the SMTP Server reverse-path to [arg2]. ()

    User set SMTP Server reverse-path address

    May also be shown as 400000a300000000 or 0x400000a300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0163
    User Response
    Information only; no action is required.
  • 400000a4-00000000 : User [arg1] has removed a certificate. ()

    User removed certificate

    May also be shown as 400000a400000000 or 0x400000a400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0164
    User Response
    Information only; no action is required.
  • 400000a5-00000000 : A certificate has been revoked . ()

    A certificate has been revoked

    May also be shown as 400000a500000000 or 0x400000a500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0165
    User Response
    Information only; no action is required.
  • 400000a6-00000000 : The server was restarted for an unknown reason. ()

    The server was restarted for an unknown reason

    May also be shown as 400000a600000000 or 0x400000a600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0166
    User Response
    Information only; no action is required.
  • 400000a7-00000000 : The server is restarted by chassis control command. ()

    Server is restarted by chassis control command

    May also be shown as 400000a700000000 or 0x400000a700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0167
    User Response
    Information only; no action is required.
  • 400000a8-00000000 : The server was reset via pushbutton. ()

    Server was reset via pushbutton

    May also be shown as 400000a800000000 or 0x400000a800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0168
    User Response
    Information only; no action is required.
  • 400000a9-00000000 : The server was powered-up via power pushbutton. ()

    Server was power-up via power pushbutton

    May also be shown as 400000a900000000 or 0x400000a900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0169
    User Response
    Information only; no action is required.
  • 400000aa-00000000 : The server was restarted when the watchdog expired.. ()

    Server was restarted when the watchdog expired.

    May also be shown as 400000aa00000000 or 0x400000aa00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0170
    User Response
    Information only; no action is required.
  • 400000ab-00000000 : The server was restarted for OEM reason. ()

    Server was restarted for OEM reason

    May also be shown as 400000ab00000000 or 0x400000ab00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0171
    User Response
    Information only; no action is required.
  • 400000ac-00000000 : The server was automatically powered on because the power restore policy is set to always restore.. ()

    Server was automatically powered on because the power restore policy is set to always restore.

    May also be shown as 400000ac00000000 or 0x400000ac00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0172
    User Response
    Information only; no action is required.
  • 400000ad-00000000 : The server was automatically powered on because the power restore policy is set to restore previous power state.. ()

    Server was automatically powered on because the power restore policy is set to restore previous power state.

    May also be shown as 400000ad00000000 or 0x400000ad00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0173
    User Response
    Information only; no action is required.
  • 400000ae-00000000 : The server was reset via Platform Event Filter. ()

    Server was reset via Platform Event Filter

    May also be shown as 400000ae00000000 or 0x400000ae00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0174
    User Response
    Information only; no action is required.
  • 400000af-00000000 : The server was power-cycled via Platform Event Filter. ()

    Server was power-cycled via Platform Event Filter

    May also be shown as 400000af00000000 or 0x400000af00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0175
    User Response
    Information only; no action is required.
  • 400000b0-00000000 : The server was soft reset. ()

    Server was soft reset

    May also be shown as 400000b000000000 or 0x400000b000000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0176
    User Response
    Information only; no action is required.
  • 400000b1-00000000 : The server was powered up via Real Time Clock (scheduled power on). ()

    Server was powered up via Real Time Clock (scheduled power on)

    May also be shown as 400000b100000000 or 0x400000b100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0177
    User Response
    Information only; no action is required.
  • 400000b2-00000000 : The server was powered off for an unknown reason. ()

    Server was powered off for an unknown reason

    May also be shown as 400000b200000000 or 0x400000b200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0178
    User Response
    Information only; no action is required.
  • 400000b3-00000000 : The server was powered off by chassis control command. ()

    Server was powered off by chassis control command

    May also be shown as 400000b300000000 or 0x400000b300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0179
    User Response
    Information only; no action is required.
  • 400000b4-00000000 : The server was powered off via pushbutton. ()

    Server was powered off via pushbutton

    May also be shown as 400000b400000000 or 0x400000b400000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0180
    User Response
    Information only; no action is required.
  • 400000b5-00000000 : The server was powered off when the watchdog expired. ()

    Server was powered off when the watchdog expired.

    May also be shown as 400000b500000000 or 0x400000b500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0181
    User Response
    Information only; no action is required.
  • 400000b6-00000000 : The server stayed powered off because the power restore policy is set to always restore.. ()

    Server stayed powered off because the power restore policy is set to always restore.

    May also be shown as 400000b600000000 or 0x400000b600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0182
    User Response
    Information only; no action is required.
  • 400000b7-00000000 : The server stayed powered off because the power restore policy is set to restore previous power state.. ()

    Server stayed powered off because the power restore policy is set to restore previous power state.

    May also be shown as 400000b700000000 or 0x400000b700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0183
    User Response
    Information only; no action is required.
  • 400000b8-00000000 : The server was powered off via Platform Event Filter. ()

    Server was power off via Platform Event Filter

    May also be shown as 400000b800000000 or 0x400000b800000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0184
    User Response
    Information only; no action is required.
  • 400000b9-00000000 : The server was powered off via Real Time Clock (scheduled power off). ()

    Server was powered up via Real Time Clock (scheduled power off)

    May also be shown as 400000b900000000 or 0x400000b900000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0185
    User Response
    Information only; no action is required.
  • 400000ba-00000000 : Management Controller [arg1] reset was initiated due to Power-On-Reset. ()

    Management Controller reset was initiated due to Power-On-Reset

    May also be shown as 400000ba00000000 or 0x400000ba00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0186
    User Response
    Information only; no action is required.
  • 400000bb-00000000 : Management Controller [arg1] reset was initiated by PRESET. ()

    Management Controller reset was initiated by PRESET

    May also be shown as 400000bb00000000 or 0x400000bb00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0187
    User Response
    Information only; no action is required.
  • 400000bc-00000000 : Management Controller [arg1] reset was initiated by CMM. ()

    Management Controller reset was initiated by CMM

    May also be shown as 400000bc00000000 or 0x400000bc00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0188
    User Response
    Information only; no action is required.
  • 400000bd-00000000 : Management Controller [arg1] reset was initiated by IMM firmware. ()

    Management Controller reset was initiated by IMM firmware

    May also be shown as 400000bd00000000 or 0x400000bd00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0189
    User Response
    Information only; no action is required.
  • 400000be-00000000 : The [arg1] certificate is expired and has been removed. ()

    Expired certificate has been removed

    May also be shown as 400000be00000000 or 0x400000be00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0190
    User Response
    Information only; no action is required.
  • 400000bf-00000000 : Operating System status has changed to [arg1]. ()

    Operating System status change

    May also be shown as 400000bf00000000 or 0x400000bf00000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0191
    User Response
    Information only; no action is required.
  • 400000c1-00000000 : System running in setup. ()

    System running in setup

    May also be shown as 400000c100000000 or 0x400000c100000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0193
    User Response
    Information only; no action is required.
  • 400000c2-00000000 : Remote Control session started by user [arg1] in [arg2] mode has been closed. ()

    Remote Control session closed

    May also be shown as 400000c200000000 or 0x400000c200000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    none
    SNMP Trap ID
    CIM Information
    Prefix: IMM ID: 0194
    User Response
    Information only; no action is required.
  • 400000c3-00000000 : Call Home to [arg1] failed to complete: [arg2]. ()

    Call Home failed to complete.

    May also be shown as 400000c300000000 or 0x400000c300000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0195
    User Response
    Information only; no action is required.
  • 400000c5-00000000 : UEFI deployment boot mode is enabled for NextBoot. ()

    UEFI deployment boot mode is enabled for NextBoot

    May also be shown as 400000c500000000 or 0x400000c500000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0197
    User Response
    Information only; no action is required.
  • 400000c6-00000000 : UEFI deployment boot mode is enabled for NextAc. ()

    UEFI deployment boot mode is enabled for NextAC

    May also be shown as 400000c600000000 or 0x400000c600000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0198
    User Response
    Information only; no action is required.
  • 400000c7-00000000 : UEFI deployment boot mode has been disabled. ()

    UEFI deployment boot mode has been disabled

    May also be shown as 400000c700000000 or 0x400000c700000000

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: IMM ID: 0199
    User Response
    Information only; no action is required.
  • 80010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (SysBrd 12V)

    This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted.

    May also be shown as 800102020701ffff or 0x800102020701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    If the specified sensor is CMOS battery, replace the system battery. If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only) replace the system board. If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
    1. Check power supply n LED.
    2. Remove the failing power supply.
    3. Follow actions in "Power Problems and Solving Power Problems".
    4. (Trained technician only) Replace the system board. (n = power supply number)
    SysBrd 3.3V : SysBrd 5V :
  • 80010202-2801ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. (CMOS Battery)

    This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted.

    May also be shown as 800102022801ffff or 0x800102022801ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0480
    User Response
    If the specified sensor is CMOS battery, replace the system battery. If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only) replace the system board. If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
    1. Check power supply n LED.
    2. Remove the failing power supply.
    3. Follow actions in "Power Problems and Solving Power Problems".
    4. (Trained technician only) Replace the system board. (n = power supply number)
  • 80010701-3701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted. (Inlet Temp)

    This message is for the use case when an implementation has detected an Upper Non-critical sensor going high has asserted.

    May also be shown as 800107013701ffff or 0x800107013701ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0490
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n.
    4. (Trained technician only) Replace system board.
  • 80010901-3701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted. (Inlet Temp)

    This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted.

    May also be shown as 800109013701ffff or 0x800109013701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n.
    4. (Trained technician only) Replace system board.
  • 80010902-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted. (SysBrd 12V)

    This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted.

    May also be shown as 800109020701ffff or 0x800109020701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0494
    User Response
    If the specified sensor is Planar 3.3V or Planar 5V, (Trained technician only) replace the system board. If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
    1. Check power supply n LED.
    2. Remove the failing power supply.
    3. (Trained technician only) Replace the system board. (n = power supply number)
    SysBrd 3.3V : SysBrd 5V :
  • 80010b01-3701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted. (Inlet Temp)

    This message is for the use case when an implementation has detected an Upper Non-recoverable sensor going high has asserted.

    May also be shown as 80010b013701ffff or 0x80010b013701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0498
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n.
    4. (Trained technician only) Replace system board.
  • 80030006-2101ffff : Sensor [SensorElementName] has deasserted. (Sig Verify Fail)

    This message is for the use case when an implementation has detected a Sensor has deasserted.

    May also be shown as 800300062101ffff or 0x800300062101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0509
    User Response
    No action; information only.
  • 8003010d-2b81ffff : Sensor [SensorElementName] has asserted. (FDIMM Config)

    This message is for the use case when an implementation has detected a Sensor has asserted.

    May also be shown as 8003010d2b81ffff or 0x8003010d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    1. Replace the power supply with higher rated power.
    2. Reduce the total power consumption by removing newly added or unused option like drives or adapters.
  • 8003010e-2581ffff : Sensor [SensorElementName] has asserted. (Memory Resized)

    This message is for the use case when an implementation has detected a Sensor has asserted.

    May also be shown as 8003010e2581ffff or 0x8003010e2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    1. Replace the power supply with higher rated power.
    2. Reduce the total power consumption by removing newly added or unused option like drives or adapters.
  • 8003010f-2101ffff : Sensor [SensorElementName] has asserted. (IMM FW Corrupted)

    This message is for the use case when an implementation has detected a Sensor has asserted.

    May also be shown as 8003010f2101ffff or 0x8003010f2101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    1. Replace the power supply with higher rated power.
    2. Reduce the total power consumption by removing newly added or unused option like drives or adapters.
  • 80030112-0601ffff : Sensor [SensorElementName] has asserted. (SMM Mode)

    This message is for the use case when an implementation has detected a Sensor has asserted.

    May also be shown as 800301120601ffff or 0x800301120601ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    1. Replace the power supply with higher rated power.
    2. Reduce the total power consumption by removing newly added or unused option like drives or adapters.
    SMM Monitor :
  • 80030118-1701ffff : Sensor [SensorElementName] has asserted. (Invalid NEBs Cfg)

    This message is for the use case when an implementation has detected a Sensor has asserted.

    May also be shown as 800301181701ffff or 0x800301181701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    1. Replace the power supply with higher rated power.
    2. Reduce the total power consumption by removing newly added or unused option like drives or adapters.
  • 8005010d-2b81ffff : Sensor [SensorElementName] has indicated limit exceeded. (FDIMM TempLimit)

    This message is for the use case when an implementation has detected a Sensor limit was exceeded.

    May also be shown as 8005010d2b81ffff or 0x8005010d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0512
    User Response
    No action; information only.
  • 8007000d-0b01ffff : Sensor [SensorElementName] has transitioned to normal state. (RAID #1 Volume)

    This message is for the use case when an implementation has detected a Sensor transition to the normal state.

    May also be shown as 8007000d0b01ffff or 0x8007000d0b01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0518
    User Response
    No action; information only.
  • 8007000d-0b03ffff : Sensor [SensorElementName] has transitioned to normal state. (RAID #3 Volume)

    This message is for the use case when an implementation has detected a Sensor transition to the normal state.

    May also be shown as 8007000d0b03ffff or 0x8007000d0b03ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0518
    User Response
    No action; information only.
  • 80070101-0301ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (CPU 1 Overtemp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 800701010301ffff or 0x800701010301ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    1. Check the microprocessor installed is Intel E5-2690.
    2. Reduce the ambient temperature under 27 Celsius degree.
  • 80070101-0302ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (CPU 2 Overtemp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 800701010302ffff or 0x800701010302ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    1. Check the microprocessor installed is Intel E5-2690.
    2. Reduce the ambient temperature under 27 Celsius degree.
  • 80070101-2c01ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (Mezz Exp 1 Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 800701012c01ffff or 0x800701012c01ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    1. Check the microprocessor installed is Intel E5-2690.
    2. Reduce the ambient temperature under 27 Celsius degree.
  • 80070101-2c02ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (Mezz Exp 2 Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 800701012c02ffff or 0x800701012c02ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    1. Check the microprocessor installed is Intel E5-2690.
    2. Reduce the ambient temperature under 27 Celsius degree.
  • 80070101-2c05ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (LOM Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 800701012c05ffff or 0x800701012c05ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    1. Check the microprocessor installed is Intel E5-2690.
    2. Reduce the ambient temperature under 27 Celsius degree.
  • 8007010d-0b01ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (RAID #1 Volume)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 8007010d0b01ffff or 0x8007010d0b01ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    None
  • 8007010d-0b03ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (RAID #3 Volume)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 8007010d0b03ffff or 0x8007010d0b03ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    None
  • 8007010d-2b81ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (FDIMM Warranty)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 8007010d2b81ffff or 0x8007010d2b81ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    None
  • 8007010f-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (GPT Status)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 8007010f2201ffff or 0x8007010f2201ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    1. Check the IBM support site for service bulletins or firmware updates that apply to this GPT error.
    2. Set the UEFI setting DISK GPT Recovery to Automatic.
    3. Replace the corrupt disk.
  • 8007010f-2582ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (I/O Resources)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 8007010f2582ffff or 0x8007010f2582ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    1. Check the IBM support site for service bulletins or firmware updates that apply to this GPT error.
    2. Set the UEFI setting DISK GPT Recovery to Automatic.
    3. Replace the corrupt disk.
  • 80070112-0b01ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (RAID Warn Log)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 800701120b01ffff or 0x800701120b01ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    None
  • 80070114-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (TPM Lock)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.

    May also be shown as 800701142201ffff or 0x800701142201ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0520
    User Response
    1. Complete the administrative tasks that require the TPM physical presence switch to be in the ON position.
    2. Restore the physical presence switch to the OFF position.
    3. Reboot the system.
    4. (Trained technician only) If the error continues, replace the planar.
    TPM Phy Pres Set :
  • 80070201-2d01ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (PCH Overtemp)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 800702012d01ffff or 0x800702012d01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffles are in place and correctly installed, and that the server cover is installed and completely closes.
    2. Check the ambient temperature. You must be operating within the specifications (see Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n is installed correctly.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 80070202-0701ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (SysBrd Vol Fault)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 800702020701ffff or 0x800702020701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check the system-event log.
    2. Check for an error LED on the system board.
    3. Replace any failing device.
    4. Check for a server firmware update. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    5. (Trained technician only) Replace the system board.
  • 8007020d-0b01ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (RAID #1 Volume)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 8007020d0b01ffff or 0x8007020d0b01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    None
  • 8007020d-0b03ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (RAID #3 Volume)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 8007020d0b03ffff or 0x8007020d0b03ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    None
  • 8007020d-2b81ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (FDIMM Warranty)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 8007020d2b81ffff or 0x8007020d2b81ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    None
  • 8007020f-2201ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (TXT ACM Module)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 8007020f2201ffff or 0x8007020f2201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. If enabling TXT is not required, disable TXT from the Setup Utility.
    2. If enabling TXT is required, verify that the TPM is enabled and activated from the Setup Utility.
    3. If the problem remains, contact your service representative.
  • 8007020f-2582ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (I/O Resources)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 8007020f2582ffff or 0x8007020f2582ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. If enabling TXT is not required, disable TXT from the Setup Utility.
    2. If enabling TXT is required, verify that the TPM is enabled and activated from the Setup Utility.
    3. If the problem remains, contact your service representative.
  • 80070212-0b02ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (RAID Error Log)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 800702120b02ffff or 0x800702120b02ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    None
  • 80070217-2c01ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (M5115 Flt Buf)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 800702172c01ffff or 0x800702172c01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    None M5115 Flt SCp : Mezz Exp 1 Fault :
  • 80070217-2c02ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (Mezz Exp 2 Fault)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 800702172c02ffff or 0x800702172c02ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    None
  • 80070219-0701ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (Sys Board Fault)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 800702190701ffff or 0x800702190701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check for an error LED on the system board.
    2. Check the system-event log.
    3. Check for the system firmware version and update to the latest version. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    4. Unplug and restore AC power cord, then, perform step 1 and 2 again.
    5. If problems still occurred, (trained technician only) replace the system board.
  • 8007021b-0301ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 1 QPILinkErr)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 8007021b0301ffff or 0x8007021b0301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check for a server firmware update.
    2. Make sure that the installed microprocessors are compatible.
    3. Make sure the microprocessor 2 expansion board is installed correctly (see Installing the microprocessor 2 expansion board).
    4. (Trained technician only) Replace microprocessor
    5. (Trained technician only) Replace microprocessor 2 expansion board.
  • 8007021b-0302ffff : Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 2 QPILinkErr)

    This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

    May also be shown as 8007021b0302ffff or 0x8007021b0302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0522
    User Response
    1. Check for a server firmware update.
    2. Make sure that the installed microprocessors are compatible.
    3. Make sure the microprocessor 2 expansion board is installed correctly (see Installing the microprocessor 2 expansion board).
    4. (Trained technician only) Replace microprocessor
    5. (Trained technician only) Replace microprocessor 2 expansion board.
  • 80070301-0301ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (CPU 1 Overtemp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 800703010301ffff or 0x800703010301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 80070301-0302ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (CPU 2 Overtemp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 800703010302ffff or 0x800703010302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 80070301-2c01ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (Mezz Exp 1 Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 800703012c01ffff or 0x800703012c01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 80070301-2c02ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (Mezz Exp 2 Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 800703012c02ffff or 0x800703012c02ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 80070301-2c05ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (LOM Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 800703012c05ffff or 0x800703012c05ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 80070301-2d01ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (PCH Overtemp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 800703012d01ffff or 0x800703012d01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
    3. Make sure that the heat sink for microprocessor n.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 8007030d-0b01ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (RAID #1 Volume)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 8007030d0b01ffff or 0x8007030d0b01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    None
  • 8007030d-0b03ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (RAID #3 Volume)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 8007030d0b03ffff or 0x8007030d0b03ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    None
  • 8007030d-2b81ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (FDIMM Warranty)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 8007030d2b81ffff or 0x8007030d2b81ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    None
  • 80070319-2201ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (S3 Resume Fail)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable from less severe.

    May also be shown as 800703192201ffff or 0x800703192201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0524
    User Response
    None
  • 80070401-2c01ffff : Sensor [SensorElementName] has transitioned to non-critical from a more severe state. (Mezz Exp 1 Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from more severe.

    May also be shown as 800704012c01ffff or 0x800704012c01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0526
    User Response
    No action; information only.
  • 80070401-2c02ffff : Sensor [SensorElementName] has transitioned to non-critical from a more severe state. (Mezz Exp 2 Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from more severe.

    May also be shown as 800704012c02ffff or 0x800704012c02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0526
    User Response
    No action; information only.
  • 80070401-2c05ffff : Sensor [SensorElementName] has transitioned to non-critical from a more severe state. (LOM Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from more severe.

    May also be shown as 800704012c05ffff or 0x800704012c05ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0526
    User Response
    No action; information only.
  • 80070601-2c01ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (Mezz Exp 1 Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

    May also be shown as 800706012c01ffff or 0x800706012c01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    None
  • 80070601-2c02ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (Mezz Exp 2 Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

    May also be shown as 800706012c02ffff or 0x800706012c02ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    None
  • 80070601-2c05ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (LOM Temp)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

    May also be shown as 800706012c05ffff or 0x800706012c05ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    None
  • 8007060f-2201ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (BOFM Config Err)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

    May also be shown as 8007060f2201ffff or 0x8007060f2201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    None
  • 80070614-2201ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (TPM Phy Pres Set)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

    May also be shown as 800706142201ffff or 0x800706142201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    1. Update the server firmware (see Recovering the server firmware).
    2. If the problem persists, (trained technician only) replace the system board (see Removing the system board and Installing the system board).
  • 80070617-2c01ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (Mezz Exp 1 Fault)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

    May also be shown as 800706172c01ffff or 0x800706172c01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    None
  • 80070617-2c02ffff : Sensor [SensorElementName] has transitioned to non-recoverable. (Mezz Exp 2 Fault)

    This message is for the use case when an implementation has detected a Sensor transitioned to non-recoverable.

    May also be shown as 800706172c02ffff or 0x800706172c02ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0530
    User Response
    None
  • 80080017-0f01ffff : Device [LogicalDeviceElementName] has been removed from unit [PhysicalPackageElementName]. (SAS BP)

    This message is for the use case when an implementation has detected a Device was removed.

    May also be shown as 800800170f01ffff or 0x800800170f01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0537
    User Response
    No action; information only.
  • 8008010f-2101ffff : Device [LogicalDeviceElementName] has been added. (Phy Presence Jmp)

    This message is for the use case when an implementation has detected a Device was inserted.

    May also be shown as 8008010f2101ffff or 0x8008010f2101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0536
    User Response
    No action; information only.
  • 80080128-2101ffff : Device [LogicalDeviceElementName] has been added. (Low Security Jmp)

    This message is for the use case when an implementation has detected a Device was inserted.

    May also be shown as 800801282101ffff or 0x800801282101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0536
    User Response
    No action; information only.
  • 8009000c-0701ffff : Device [LogicalDeviceElementName] has been disabled. (Performance Mode)

    This message is for the use case when an implementation has detected a Device was disabled.

    May also be shown as 8009000c0701ffff or 0x8009000c0701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0539
    User Response
    No action; information only.
  • 8009010c-0701ffff : Device [LogicalDeviceElementName] has been enabled. (Performance Mode)

    This message is for the use case when an implementation has detected a Device was enabled.

    May also be shown as 8009010c0701ffff or 0x8009010c0701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0538
    User Response
    No action; information only.
  • 80090112-2101ffff : Device [LogicalDeviceElementName] has been enabled. (IPMI/SNMP Accts)

    This message is for the use case when an implementation has detected a Device was enabled.

    May also be shown as 800901122101ffff or 0x800901122101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0538
    User Response
    No action; information only.
  • 800a030d-2b81ffff : Sensor [SensorElementName] has indicated a on-line state. (FDIMM Mode)

    This message is for the use case when an implementation has detected a Sensor transitioned to on-line.

    May also be shown as 800a030d2b81ffff or 0x800a030d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0546
    User Response
    No action; information only.
  • 800a040d-2b81ffff : Sensor [SensorElementName] has indicated an off-line state. (FDIMM Mode)

    This message is for the use case when an implementation has detected a Sensor transitioned to off-line.

    May also be shown as 800a040d2b81ffff or 0x800a040d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0548
    User Response
    No action; information only.
  • 800a060d-2b81ffff : Sensor [SensorElementName] has indicated a degraded state. (FDIMM Mode)

    This message is for the use case when an implementation has detected a Sensor transitioned to a degraded state.

    May also be shown as 800a060d2b81ffff or 0x800a060d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0552
    User Response
    No action; information only.
  • 800b010c-2581ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Backup Memory)

    This message is for the use case when Redundancy Lost has asserted.

    May also be shown as 800b010c2581ffff or 0x800b010c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0802
    User Response
    1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
    2. Re-enable mirroring in the Setup utility.
  • 800b030c-2581ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted. (Backup Memory)

    This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or Fully Redundant to Non-redundant:Sufficient.

    May also be shown as 800b030c2581ffff or 0x800b030c2581ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0806
    User Response
    1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
    2. Re-enable mirroring in the Setup utility.
  • 800b050c-2581ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted. (Backup Memory)

    This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient Resources.

    May also be shown as 800b050c2581ffff or 0x800b050c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0810
    User Response
    1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
    2. Re-enable mirroring in the Setup utility.
  • 806f0007-0301ffff : [ProcessorElementName] has Failed with IERR. (CPU 1)

    This message is for the use case when an implementation has detected a Processor Failed - IERR Condition.

    May also be shown as 806f00070301ffff or 0x806f00070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0042
    User Response
    1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    2. Run the DSA program.
    3. Reseat the adapter.
    4. Replace the adapter.
    5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    6. (Trained technician only) Replace the system board.
  • 806f0007-0302ffff : [ProcessorElementName] has Failed with IERR. (CPU 2)

    This message is for the use case when an implementation has detected a Processor Failed - IERR Condition.

    May also be shown as 806f00070302ffff or 0x806f00070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0042
    User Response
    1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    2. Run the DSA program.
    3. Reseat the adapter.
    4. Replace the adapter.
    5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    6. (Trained technician only) Replace the system board.
  • 806f0007-2584ffff : [ProcessorElementName] has Failed with IERR. (All CPUs)

    This message is for the use case when an implementation has detected a Processor Failed - IERR Condition.

    May also be shown as 806f00072584ffff or 0x806f00072584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0042
    User Response
    1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    2. Run the DSA program.
    3. Reseat the adapter.
    4. Replace the adapter.
    5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    6. (Trained technician only) Replace the system board.
    One of CPUs :
  • 806f0009-0701ffff : [PowerSupplyElementName] has been turned off. (Host Power)

    This message is for the use case when an implementation has detected a Power Unit that has been Disabled.

    May also be shown as 806f00090701ffff or 0x806f00090701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Power Off
    SNMP Trap ID
    23
    CIM Information
    Prefix: PLAT ID: 0106
    User Response
    No action; information only.
  • 806f000d-0400ffff : The [StorageVolumeElementName] has been added. (Drive 0)

    This message is for the use case when an implementation has detected a Drive has been Added.

    May also be shown as 806f000d0400ffff or 0x806f000d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    No action; information only.
  • 806f000d-0401ffff : The [StorageVolumeElementName] has been added. (Drive 1)

    This message is for the use case when an implementation has detected a Drive has been Added.

    May also be shown as 806f000d0401ffff or 0x806f000d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    No action; information only.
  • 806f000d-0402ffff : The [StorageVolumeElementName] has been added. (Drive 2)

    This message is for the use case when an implementation has detected a Drive has been Added.

    May also be shown as 806f000d0402ffff or 0x806f000d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    No action; information only.
  • 806f000d-0403ffff : The [StorageVolumeElementName] has been added. (Drive 3)

    This message is for the use case when an implementation has detected a Drive has been Added.

    May also be shown as 806f000d0403ffff or 0x806f000d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    No action; information only.
  • 806f000d-0404ffff : The [StorageVolumeElementName] has been added. (Drive 4)

    This message is for the use case when an implementation has detected a Drive has been Added.

    May also be shown as 806f000d0404ffff or 0x806f000d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    No action; information only.
  • 806f000d-0405ffff : The [StorageVolumeElementName] has been added. (Drive 5)

    This message is for the use case when an implementation has detected a Drive has been Added.

    May also be shown as 806f000d0405ffff or 0x806f000d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    No action; information only.
  • 806f000d-0406ffff : The [StorageVolumeElementName] has been added. (Drive 6)

    This message is for the use case when an implementation has detected a Drive has been Added.

    May also be shown as 806f000d0406ffff or 0x806f000d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    No action; information only.
  • 806f000d-0407ffff : The [StorageVolumeElementName] has been added. (Drive 7)

    This message is for the use case when an implementation has detected a Drive has been Added.

    May also be shown as 806f000d0407ffff or 0x806f000d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0162
    User Response
    No action; information only.
  • 806f000f-220101ff : The System [ComputerSystemElementName] has detected no memory in the system. (ABR Status)

    This message is for the use case when an implementation has detected that memory was detected in the system.

    May also be shown as 806f000f220101ff or 0x806f000f220101ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0794
    User Response
    This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
  • 806f000f-220102ff : Subsystem [MemoryElementName] has insufficient memory for operation. (ABR Status)

    This message is for the use case when an implementation has detected that the usable Memory is insufficient for operation.

    May also be shown as 806f000f220102ff or 0x806f000f220102ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0132
    User Response
    This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
  • 806f000f-220103ff : The System [ComputerSystemElementName] encountered firmware error - unrecoverable boot device failure. (ABR Status)

    This message is for the use case when an implementation has detected that System Firmware Error Unrecoverable boot device failure has occurred.

    May also be shown as 806f000f220103ff or 0x806f000f220103ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0770
    User Response
    This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
  • 806f000f-220104ff : The System [ComputerSystemElementName]has encountered a motherboard failure. (ABR Status)

    This message is for the use case when an implementation has detected that a fatal motherboard failure in the system.

    May also be shown as 806f000f220104ff or 0x806f000f220104ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0795
    User Response
    This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
  • 806f000f-220107ff : The System [ComputerSystemElementName] encountered firmware error - unrecoverable keyboard failure. (ABR Status)

    This message is for the use case when an implementation has detected that System Firmware Error Unrecoverable Keyboard failure has occurred.

    May also be shown as 806f000f220107ff or 0x806f000f220107ff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0764
    User Response
    This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
  • 806f000f-22010aff : The System [ComputerSystemElementName] encountered firmware error - no video device detected. (ABR Status)

    This message is for the use case when an implementation has detected that System Firmware Error No video device detected has occurred.

    May also be shown as 806f000f22010aff or 0x806f000f22010aff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0766
    User Response
    This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
  • 806f000f-22010bff : Firmware BIOS (ROM) corruption was detected on system [ComputerSystemElementName] during POST. (ABR Status)

    Firmware BIOS (ROM) corruption was detected on the system during POST.

    May also be shown as 806f000f22010bff or 0x806f000f22010bff

    Severity
    Info
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0850
    User Response
    1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
    2. Recover the server firmware from the backup page: a.Restart the server. b.At the prompt, press F3 to recover the firmware.
    3. Update the server firmware to the latest level (see Updating the firmware). Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    4. Remove components one at a time, restarting the server each time, to see if the problem goes away.
    5. If the problem remains, (trained service technician) replace the system board.
    Firmware Error : Sys Boot Status :
  • 806f000f-22010cff : CPU voltage mismatch detected on [ProcessorElementName]. (ABR Status)

    This message is for the use case when an implementation has detected a CPU voltage mismatch with the socket voltage.

    May also be shown as 806f000f22010cff or 0x806f000f22010cff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0050
    User Response
    This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
  • 806f000f-2201ffff : The System [ComputerSystemElementName] encountered a POST Error. (ABR Status)

    This message is for the use case when an implementation has detected a Post Error.

    May also be shown as 806f000f2201ffff or 0x806f000f2201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0184
    User Response
    This is a UEFI detected event. The UEFI(POST) error code for this event can be found in the logged IMM message text. Please refer to the UEFI(POST) error code in the "UEFI(POST) error code" section of the Information Center for the appropriate user response. Firmware Error : Sys Boot Status :
  • 806f0013-1701ffff : A diagnostic interrupt has occurred on system [ComputerSystemElementName]. (NMI State)

    This message is for the use case when an implementation has detected a Front Panel NMI / Diagnostic Interrupt.

    May also be shown as 806f00131701ffff or 0x806f00131701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0222
    User Response
    If the NMI button has not been pressed, complete the following steps:
    1. Make sure that the NMI button is not pressed.
    2. Replace the operator information panel cable.
    3. Replace the operator information panel.
  • 806f001e-2201ffff : No bootable media available for system [ComputerSystemElementName]. (No Boot Device)

    This message is for the use case when an implementation has detected a System with No Bootable Media.

    May also be shown as 806f001e2201ffff or 0x806f001e2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0286
    User Response
    No action; information only.
  • 806f0021-2201ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. (No Op ROM Space)

    This message is for the use case when an implementation has detected a Fault in a slot.

    May also be shown as 806f00212201ffff or 0x806f00212201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    1. Check the PCI LED.
    2. Reseat the affected adapters and riser card.
    3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    4. Replace the affected adapters.
    5. Replace the riser card.
    6. (Trained service technicians only) Replace the system board.
  • 806f0021-2582ffff : Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. (PCIe Error)

    This message is for the use case when an implementation has detected a Fault in a slot.

    May also be shown as 806f00212582ffff or 0x806f00212582ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0330
    User Response
    1. Check the PCI LED.
    2. Reseat the affected adapters and riser card.
    3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    4. Replace the affected adapters.
    5. Replace the riser card.
    6. (Trained service technicians only) Replace the system board.
  • 806f0023-2101ffff : Watchdog Timer expired for [WatchdogElementName]. (IPMI Watchdog)

    This message is for the use case when an implementation has detected a Watchdog Timer Expired.

    May also be shown as 806f00232101ffff or 0x806f00232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0368
    User Response
    No action; information only.
  • 806f0028-2101ffff : Sensor [SensorElementName] is unavailable or degraded on management system [ComputerSystemElementName]. (TPM Cmd Failures)

    This message is for the use case when an implementation has detected a Sensor is Unavailable or degraded.

    May also be shown as 806f00282101ffff or 0x806f00282101ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0398
    User Response
    1. Turn off the server and disconnect the power cords. Reconnect the power cords and restart the server.
    2. If the problem remains, (trained technician only) replace the system board.
  • 806f0107-0301ffff : An Over-Temperature Condition has been detected on [ProcessorElementName]. (CPU 1)

    This message is for the use case when an implementation has detected an Over-Temperature Condition Detected for Processor.

    May also be shown as 806f01070301ffff or 0x806f01070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0036
    User Response
    1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of the server), the air baffles are in place and correctly installed, and the server cover is installed and completely closed.
    2. Make sure that the heat sink for microprocessor n is installed correctly.
    3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 806f0107-0302ffff : An Over-Temperature Condition has been detected on [ProcessorElementName]. (CPU 2)

    This message is for the use case when an implementation has detected an Over-Temperature Condition Detected for Processor.

    May also be shown as 806f01070302ffff or 0x806f01070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0036
    User Response
    1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of the server), the air baffles are in place and correctly installed, and the server cover is installed and completely closed.
    2. Make sure that the heat sink for microprocessor n is installed correctly.
    3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 806f0107-2584ffff : An Over-Temperature Condition has been detected on [ProcessorElementName]. (All CPUs)

    This message is for the use case when an implementation has detected an Over-Temperature Condition Detected for Processor.

    May also be shown as 806f01072584ffff or 0x806f01072584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0036
    User Response
    1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of the server), the air baffles are in place and correctly installed, and the server cover is installed and completely closed.
    2. Make sure that the heat sink for microprocessor n is installed correctly.
    3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    One of CPUs :
  • 806f0109-0701ffff : [PowerSupplyElementName] has been Power Cycled. (Host Power)

    This message is for the use case when an implementation has detected a Power Unit that has been power cycled.

    May also be shown as 806f01090701ffff or 0x806f01090701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0108
    User Response
    No action; information only.
  • 806f010c-2001ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2001ffff or 0x806f010c2001ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2002ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2002ffff or 0x806f010c2002ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2003ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2003ffff or 0x806f010c2003ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2004ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2004ffff or 0x806f010c2004ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2005ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2005ffff or 0x806f010c2005ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2006ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2006ffff or 0x806f010c2006ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2007ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2007ffff or 0x806f010c2007ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2008ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2008ffff or 0x806f010c2008ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2009ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2009ffff or 0x806f010c2009ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-200affff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c200affff or 0x806f010c200affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-200bffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c200bffff or 0x806f010c200bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-200cffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c200cffff or 0x806f010c200cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-200dffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c200dffff or 0x806f010c200dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-200effff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c200effff or 0x806f010c200effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-200fffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c200fffff or 0x806f010c200fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2010ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2010ffff or 0x806f010c2010ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2011ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2011ffff or 0x806f010c2011ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2012ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2012ffff or 0x806f010c2012ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2013ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2013ffff or 0x806f010c2013ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2014ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2014ffff or 0x806f010c2014ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2015ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2015ffff or 0x806f010c2015ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2016ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2016ffff or 0x806f010c2016ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2017ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2017ffff or 0x806f010c2017ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2018ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2018ffff or 0x806f010c2018ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f010c-2581ffff : Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (All DIMMs)

    This message is for the use case when an implementation has detected a Memory uncorrectable error.

    May also be shown as 806f010c2581ffff or 0x806f010c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0138
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
    One of the DIMMs :
  • 806f010d-0400ffff : The [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 0)

    This message is for the use case when an implementation has detected a Drive was Disabled due to fault.

    May also be shown as 806f010d0400ffff or 0x806f010d0400ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f010d-0401ffff : The [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 1)

    This message is for the use case when an implementation has detected a Drive was Disabled due to fault.

    May also be shown as 806f010d0401ffff or 0x806f010d0401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f010d-0402ffff : The [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 2)

    This message is for the use case when an implementation has detected a Drive was Disabled due to fault.

    May also be shown as 806f010d0402ffff or 0x806f010d0402ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f010d-0403ffff : The [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 3)

    This message is for the use case when an implementation has detected a Drive was Disabled due to fault.

    May also be shown as 806f010d0403ffff or 0x806f010d0403ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f010d-0404ffff : The [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 4)

    This message is for the use case when an implementation has detected a Drive was Disabled due to fault.

    May also be shown as 806f010d0404ffff or 0x806f010d0404ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f010d-0405ffff : The [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 5)

    This message is for the use case when an implementation has detected a Drive was Disabled due to fault.

    May also be shown as 806f010d0405ffff or 0x806f010d0405ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f010d-0406ffff : The [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 6)

    This message is for the use case when an implementation has detected a Drive was Disabled due to fault.

    May also be shown as 806f010d0406ffff or 0x806f010d0406ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f010d-0407ffff : The [StorageVolumeElementName] has been disabled due to a detected fault. (Drive 7)

    This message is for the use case when an implementation has detected a Drive was Disabled due to fault.

    May also be shown as 806f010d0407ffff or 0x806f010d0407ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f010d-2b81ffff : The [StorageVolumeElementName] has been disabled due to a detected fault. (FDIMM Stat)

    This message is for the use case when an implementation has detected a Drive was Disabled due to fault.

    May also be shown as 806f010d2b81ffff or 0x806f010d2b81ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0164
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f010f-2201ffff : The System [ComputerSystemElementName] encountered a firmware hang. (Firmware Error)

    This message is for the use case when an implementation has detected a System Firmware Hang.

    May also be shown as 806f010f2201ffff or 0x806f010f2201ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Boot failure
    SNMP Trap ID
    25
    CIM Information
    Prefix: PLAT ID: 0186
    User Response
    1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
    2. Update the server firmware on the primary page. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    3. (Trained technician only) Replace the system board.
  • 806f011b-0c01ffff : The connector [PhysicalConnectorElementName] has encountered a configuration error. (LightPath)

    This message is for the use case when an implementation has detected an Interconnect Configuration Error.

    May also be shown as 806f011b0c01ffff or 0x806f011b0c01ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0266
    User Response
    If the specified sensor is front USB connector, reset the front USB cable on the system board. If the specified sensor is front video connector, reset the front video cable in the system board. If the specified sensor is PwrPaddle cable, complete the following steps until problem is solved:
    1. Reseat the power paddle cable on the system board.
    2. Replace the power paddle cable.
    3. (Trained technician only) Replace the supercap n. (n = supercap number)
    4. (Trained technician only) Replace the system board.
  • 806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by [WatchdogElementName]. (IPMI Watchdog)

    This message is for the use case when an implementation has detected a Reboot by a Watchdog occurred.

    May also be shown as 806f01232101ffff or 0x806f01232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0370
    User Response
    No action; information only.
  • 806f0125-1f05ffff : [ManagedElementName] detected as absent. (LOM)

    This message is for the use case when an implementation has detected a Managed Element is Absent.

    May also be shown as 806f01251f05ffff or 0x806f01251f05ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0392
    User Response
    Please ensure the PCI riser 1 has been installed correctly.
  • 806f0207-0301ffff : [ProcessorElementName] has Failed with FRB1/BIST condition. (CPU 1)

    This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST condition.

    May also be shown as 806f02070301ffff or 0x806f02070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0044
    User Response
    1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    2. Run the DSA program.
    3. Reseat the adapter.
    4. Replace the adapter.
    5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    6. (Trained technician only) Replace the system board.
  • 806f0207-0302ffff : [ProcessorElementName] has Failed with FRB1/BIST condition. (CPU 2)

    This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST condition.

    May also be shown as 806f02070302ffff or 0x806f02070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0044
    User Response
    1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    2. Run the DSA program.
    3. Reseat the adapter.
    4. Replace the adapter.
    5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    6. (Trained technician only) Replace the system board.
  • 806f0207-2584ffff : [ProcessorElementName] has Failed with FRB1/BIST condition. (All CPUs)

    This message is for the use case when an implementation has detected a Processor Failed - FRB1/BIST condition.

    May also be shown as 806f02072584ffff or 0x806f02072584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0044
    User Response
    1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    2. Run the DSA program.
    3. Reseat the adapter.
    4. Replace the adapter.
    5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    6. (Trained technician only) Replace the system board.
    One of CPUs :
  • 806f020d-0400ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 0)

    This message is for the use case when an implementation has detected an Array Failure is Predicted.

    May also be shown as 806f020d0400ffff or 0x806f020d0400ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f020d-0401ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 1)

    This message is for the use case when an implementation has detected an Array Failure is Predicted.

    May also be shown as 806f020d0401ffff or 0x806f020d0401ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f020d-0402ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 2)

    This message is for the use case when an implementation has detected an Array Failure is Predicted.

    May also be shown as 806f020d0402ffff or 0x806f020d0402ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f020d-0403ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 3)

    This message is for the use case when an implementation has detected an Array Failure is Predicted.

    May also be shown as 806f020d0403ffff or 0x806f020d0403ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f020d-0404ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 4)

    This message is for the use case when an implementation has detected an Array Failure is Predicted.

    May also be shown as 806f020d0404ffff or 0x806f020d0404ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f020d-0405ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 5)

    This message is for the use case when an implementation has detected an Array Failure is Predicted.

    May also be shown as 806f020d0405ffff or 0x806f020d0405ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f020d-0406ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 6)

    This message is for the use case when an implementation has detected an Array Failure is Predicted.

    May also be shown as 806f020d0406ffff or 0x806f020d0406ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f020d-0407ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 7)

    This message is for the use case when an implementation has detected an Array Failure is Predicted.

    May also be shown as 806f020d0407ffff or 0x806f020d0407ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f020d-2b81ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (FDIMM Stat)

    This message is for the use case when an implementation has detected an Array Failure is Predicted.

    May also be shown as 806f020d2b81ffff or 0x806f020d2b81ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0168
    User Response
    1. Run the hard disk drive diagnostic test on drive n.
    2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
    3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
  • 806f0223-2101ffff : Powering off system [ComputerSystemElementName] initiated by [WatchdogElementName]. (IPMI Watchdog)

    This message is for the use case when an implementation has detected a Poweroff by Watchdog has occurred.

    May also be shown as 806f02232101ffff or 0x806f02232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0372
    User Response
    No action; information only.
  • 806f030c-2001ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2001ffff or 0x806f030c2001ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2002ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2002ffff or 0x806f030c2002ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2003ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2003ffff or 0x806f030c2003ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2004ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2004ffff or 0x806f030c2004ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2005ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2005ffff or 0x806f030c2005ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2006ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2006ffff or 0x806f030c2006ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2007ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2007ffff or 0x806f030c2007ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2008ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2008ffff or 0x806f030c2008ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2009ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2009ffff or 0x806f030c2009ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-200affff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c200affff or 0x806f030c200affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-200bffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c200bffff or 0x806f030c200bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-200cffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c200cffff or 0x806f030c200cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-200dffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c200dffff or 0x806f030c200dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-200effff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c200effff or 0x806f030c200effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-200fffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c200fffff or 0x806f030c200fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2010ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2010ffff or 0x806f030c2010ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2011ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2011ffff or 0x806f030c2011ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2012ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2012ffff or 0x806f030c2012ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2013ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2013ffff or 0x806f030c2013ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2014ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2014ffff or 0x806f030c2014ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2015ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2015ffff or 0x806f030c2015ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2016ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2016ffff or 0x806f030c2016ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2017ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2017ffff or 0x806f030c2017ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2018ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2018ffff or 0x806f030c2018ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
  • 806f030c-2581ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (All DIMMs)

    This message is for the use case when an implementation has detected a Memory Scrub failure.

    May also be shown as 806f030c2581ffff or 0x806f030c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0136
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Manually re-enable all affected DIMMs.
    4. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    5. If the problem follows the DIMM, replace the failing DIMM.
    6. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    7. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    8. (Trained technician only) Replace the affected microprocessor.
    One of the DIMMs :
  • 806f030d-0400ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 0)

    This message is for the use case when an implementation has detected a Hot Spare has been Enabled.

    May also be shown as 806f030d0400ffff or 0x806f030d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0170
    User Response
    No action; information only.
  • 806f030d-0401ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 1)

    This message is for the use case when an implementation has detected a Hot Spare has been Enabled.

    May also be shown as 806f030d0401ffff or 0x806f030d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0170
    User Response
    No action; information only.
  • 806f030d-0402ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 2)

    This message is for the use case when an implementation has detected a Hot Spare has been Enabled.

    May also be shown as 806f030d0402ffff or 0x806f030d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0170
    User Response
    No action; information only.
  • 806f030d-0403ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 3)

    This message is for the use case when an implementation has detected a Hot Spare has been Enabled.

    May also be shown as 806f030d0403ffff or 0x806f030d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0170
    User Response
    No action; information only.
  • 806f030d-0404ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 4)

    This message is for the use case when an implementation has detected a Hot Spare has been Enabled.

    May also be shown as 806f030d0404ffff or 0x806f030d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0170
    User Response
    No action; information only.
  • 806f030d-0405ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 5)

    This message is for the use case when an implementation has detected a Hot Spare has been Enabled.

    May also be shown as 806f030d0405ffff or 0x806f030d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0170
    User Response
    No action; information only.
  • 806f030d-0406ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 6)

    This message is for the use case when an implementation has detected a Hot Spare has been Enabled.

    May also be shown as 806f030d0406ffff or 0x806f030d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0170
    User Response
    No action; information only.
  • 806f030d-0407ffff : Hot Spare enabled for [ComputerSystemElementName]. (Drive 7)

    This message is for the use case when an implementation has detected a Hot Spare has been Enabled.

    May also be shown as 806f030d0407ffff or 0x806f030d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0170
    User Response
    No action; information only.
  • 806f0313-1701ffff : A software NMI has occurred on system [ComputerSystemElementName]. (NMI State)

    This message is for the use case when an implementation has detected a Software NMI.

    May also be shown as 806f03131701ffff or 0x806f03131701ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0228
    User Response
    1. Check the device driver.
    2. Reinstall the device driver.
    3. Update all device drivers to the latest level.
    4. Update the firmware (UEFI and IMM).
  • 806f0323-2101ffff : Power cycle of system [ComputerSystemElementName] initiated by watchdog [WatchdogElementName]. (IPMI Watchdog)

    This message is for the use case when an implementation has detected a Power Cycle by Watchdog occurred.

    May also be shown as 806f03232101ffff or 0x806f03232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0374
    User Response
    No action; information only.
  • 806f040c-2001ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2001ffff or 0x806f040c2001ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2002ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2002ffff or 0x806f040c2002ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2003ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2003ffff or 0x806f040c2003ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2004ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2004ffff or 0x806f040c2004ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2005ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2005ffff or 0x806f040c2005ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2006ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2006ffff or 0x806f040c2006ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2007ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2007ffff or 0x806f040c2007ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2008ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2008ffff or 0x806f040c2008ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2009ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2009ffff or 0x806f040c2009ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-200affff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c200affff or 0x806f040c200affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-200bffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c200bffff or 0x806f040c200bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-200cffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c200cffff or 0x806f040c200cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-200dffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c200dffff or 0x806f040c200dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-200effff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c200effff or 0x806f040c200effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-200fffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c200fffff or 0x806f040c200fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2010ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2010ffff or 0x806f040c2010ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2011ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2011ffff or 0x806f040c2011ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2012ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2012ffff or 0x806f040c2012ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2013ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2013ffff or 0x806f040c2013ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2014ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2014ffff or 0x806f040c2014ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2015ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2015ffff or 0x806f040c2015ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2016ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2016ffff or 0x806f040c2016ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2017ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2017ffff or 0x806f040c2017ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2018ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2018ffff or 0x806f040c2018ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
  • 806f040c-2581ffff : [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. (All DIMMs)

    This message is for the use case when an implementation has detected that Memory has been Disabled.

    May also be shown as 806f040c2581ffff or 0x806f040c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0131
    User Response
    1. Make sure the DIMM is installed correctly.
    2. If the DIMM was disabled because of a memory fault (memory uncorrectable error or memory logging limit reached), follow the suggested actions for that error event and restart the server.
    3. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event. If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility (ASU).
    One of the DIMMs :
  • 806f0413-2582ffff : A PCI PERR has occurred on system [ComputerSystemElementName]. (All PCI Error)

    This message is for the use case when an implementation has detected a PCI PERR.

    May also be shown as 806f04132582ffff or 0x806f04132582ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0232
    User Response
    1. Check the PCI LED.
    2. Reseat the affected adapters and riser cards.
    3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    4. Remove both adapters.
    5. Replace the PCIe adapters.
    6. Replace the riser card.
    One of PCI Error : PCIs :
  • 806f0507-0301ffff : [ProcessorElementName] has a Configuration Mismatch. (CPU 1)

    This message is for the use case when an implementation has detected a Processor Configuration Mismatch has occurred.

    May also be shown as 806f05070301ffff or 0x806f05070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0062
    User Response
    1. Make sure that the installed microprocessors are compatible with each other.
    2. (Trained technician only) Reseat microprocessor n.
    3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 806f0507-0302ffff : [ProcessorElementName] has a Configuration Mismatch. (CPU 2)

    This message is for the use case when an implementation has detected a Processor Configuration Mismatch has occurred.

    May also be shown as 806f05070302ffff or 0x806f05070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0062
    User Response
    1. Make sure that the installed microprocessors are compatible with each other.
    2. (Trained technician only) Reseat microprocessor n.
    3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 806f0507-2584ffff : [ProcessorElementName] has a Configuration Mismatch. (All CPUs)

    This message is for the use case when an implementation has detected a Processor Configuration Mismatch has occurred.

    May also be shown as 806f05072584ffff or 0x806f05072584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0062
    User Response
    1. Make sure that the installed microprocessors are compatible with each other.
    2. (Trained technician only) Reseat microprocessor n.
    3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    One of CPUs :
  • 806f050c-2001ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2001ffff or 0x806f050c2001ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2002ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2002ffff or 0x806f050c2002ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2003ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2003ffff or 0x806f050c2003ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2004ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2004ffff or 0x806f050c2004ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2005ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2005ffff or 0x806f050c2005ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2006ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2006ffff or 0x806f050c2006ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2007ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2007ffff or 0x806f050c2007ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2008ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2008ffff or 0x806f050c2008ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2009ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2009ffff or 0x806f050c2009ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-200affff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c200affff or 0x806f050c200affff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-200bffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c200bffff or 0x806f050c200bffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-200cffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c200cffff or 0x806f050c200cffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-200dffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c200dffff or 0x806f050c200dffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-200effff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c200effff or 0x806f050c200effff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-200fffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c200fffff or 0x806f050c200fffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2010ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2010ffff or 0x806f050c2010ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2011ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2011ffff or 0x806f050c2011ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2012ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2012ffff or 0x806f050c2012ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2013ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2013ffff or 0x806f050c2013ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2014ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2014ffff or 0x806f050c2014ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2015ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2015ffff or 0x806f050c2015ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2016ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2016ffff or 0x806f050c2016ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2017ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2017ffff or 0x806f050c2017ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2018ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2018ffff or 0x806f050c2018ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
  • 806f050c-2581ffff : Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (All DIMMs)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached.

    May also be shown as 806f050c2581ffff or 0x806f050c2581ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0144
    User Response
    Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server.
    1. Refer to TIP H212293 for minimum code level.
    2. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
    3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event logs) to a different memory channel or microprocessor.
    4. If the problem follows the DIMM, replace the failing DIMM.
    5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the connector contains any foreign material or is damaged, replace the system board.
    6. (Trained technician only) Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins. If a damage is found, replace the system board.
    7. (Trained technician only) Replace the affected microprocessor.
    8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10. If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server to the power source and restart the server.
    9. (Trained Service technician only) Replace the affected microprocessor.
    One of the DIMMs :
  • 806f050d-0400ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 0)

    This message is for the use case when an implementation has detected that an Array is Critical.

    May also be shown as 806f050d0400ffff or 0x806f050d0400ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Check backplane cable connection.
    5. Replace the RAID adapter.
    6. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0401ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 1)

    This message is for the use case when an implementation has detected that an Array is Critical.

    May also be shown as 806f050d0401ffff or 0x806f050d0401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Check backplane cable connection.
    5. Replace the RAID adapter.
    6. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0402ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 2)

    This message is for the use case when an implementation has detected that an Array is Critical.

    May also be shown as 806f050d0402ffff or 0x806f050d0402ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Check backplane cable connection.
    5. Replace the RAID adapter.
    6. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0403ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 3)

    This message is for the use case when an implementation has detected that an Array is Critical.

    May also be shown as 806f050d0403ffff or 0x806f050d0403ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Check backplane cable connection.
    5. Replace the RAID adapter.
    6. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0404ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 4)

    This message is for the use case when an implementation has detected that an Array is Critical.

    May also be shown as 806f050d0404ffff or 0x806f050d0404ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Check backplane cable connection.
    5. Replace the RAID adapter.
    6. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0405ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 5)

    This message is for the use case when an implementation has detected that an Array is Critical.

    May also be shown as 806f050d0405ffff or 0x806f050d0405ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Check backplane cable connection.
    5. Replace the RAID adapter.
    6. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0406ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 6)

    This message is for the use case when an implementation has detected that an Array is Critical.

    May also be shown as 806f050d0406ffff or 0x806f050d0406ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Check backplane cable connection.
    5. Replace the RAID adapter.
    6. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f050d-0407ffff : Array [ComputerSystemElementName] is in critical condition. (Drive 7)

    This message is for the use case when an implementation has detected that an Array is Critical.

    May also be shown as 806f050d0407ffff or 0x806f050d0407ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0174
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Check backplane cable connection.
    5. Replace the RAID adapter.
    6. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f0513-2582ffff : A PCI SERR has occurred on system [ComputerSystemElementName]. (All PCI Error)

    This message is for the use case when an implementation has detected a PCI SERR.

    May also be shown as 806f05132582ffff or 0x806f05132582ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0234
    User Response
    1. Check the PCI LED.
    2. Reseat the affected adapters and riser card.
    3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    4. Make sure that the adapter is supported. For a list of supported optional devices, see http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/.
    5. Remove both adapters.
    6. Replace the PCIe adapters.
    7. Replace the riser card.
    One of PCI Error : PCIs :
  • 806f052b-2101ffff : Invalid or Unsupported firmware or software was detected on system [ComputerSystemElementName]. (IMM2 FW Failover)

    This message is for the use case when an implementation has detected an Invalid/Unsupported Firmware/Software Version.

    May also be shown as 806f052b2101ffff or 0x806f052b2101ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0446
    User Response
    1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
    2. Recover the server firmware from the backup page by restarting the server.
    3. Update the server firmware to the latest level (see Updating the firmware). Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    4. Remove components one at a time, restarting the server each time, to see if the problem goes away.
    5. If the problem remains, (trained service technician) replace the system board.
  • 806f0607-0301ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted. (CPU 1)

    This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.

    May also be shown as 806f06070301ffff or 0x806f06070301ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0816
    User Response
    1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    2. Run the DSA program.
    3. Reseat the adapter.
    4. Replace the adapter.
    5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    6. (Trained technician only) Replace the system board.
  • 806f0607-0302ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted. (CPU 2)

    This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.

    May also be shown as 806f06070302ffff or 0x806f06070302ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0816
    User Response
    1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    2. Run the DSA program.
    3. Reseat the adapter.
    4. Replace the adapter.
    5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    6. (Trained technician only) Replace the system board.
  • 806f0607-2584ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted. (All CPUs)

    This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.

    May also be shown as 806f06072584ffff or 0x806f06072584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0816
    User Response
    1. Update the latest level of system firmware and device drivers are installed for all adapters and standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    2. Run the DSA program.
    3. Reseat the adapter.
    4. Replace the adapter.
    5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    6. (Trained technician only) Replace the system board.
    One of CPUs :
  • 806f060d-0400ffff : Array [ComputerSystemElementName] has failed. (Drive 0)

    This message is for the use case when an implementation has detected that an Array Failed.

    May also be shown as 806f060d0400ffff or 0x806f060d0400ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Replace the RAID adapter.
    5. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f060d-0401ffff : Array [ComputerSystemElementName] has failed. (Drive 1)

    This message is for the use case when an implementation has detected that an Array Failed.

    May also be shown as 806f060d0401ffff or 0x806f060d0401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Replace the RAID adapter.
    5. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f060d-0402ffff : Array [ComputerSystemElementName] has failed. (Drive 2)

    This message is for the use case when an implementation has detected that an Array Failed.

    May also be shown as 806f060d0402ffff or 0x806f060d0402ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Replace the RAID adapter.
    5. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f060d-0403ffff : Array [ComputerSystemElementName] has failed. (Drive 3)

    This message is for the use case when an implementation has detected that an Array Failed.

    May also be shown as 806f060d0403ffff or 0x806f060d0403ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Replace the RAID adapter.
    5. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f060d-0404ffff : Array [ComputerSystemElementName] has failed. (Drive 4)

    This message is for the use case when an implementation has detected that an Array Failed.

    May also be shown as 806f060d0404ffff or 0x806f060d0404ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Replace the RAID adapter.
    5. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f060d-0405ffff : Array [ComputerSystemElementName] has failed. (Drive 5)

    This message is for the use case when an implementation has detected that an Array Failed.

    May also be shown as 806f060d0405ffff or 0x806f060d0405ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Replace the RAID adapter.
    5. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f060d-0406ffff : Array [ComputerSystemElementName] has failed. (Drive 6)

    This message is for the use case when an implementation has detected that an Array Failed.

    May also be shown as 806f060d0406ffff or 0x806f060d0406ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Replace the RAID adapter.
    5. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f060d-0407ffff : Array [ComputerSystemElementName] has failed. (Drive 7)

    This message is for the use case when an implementation has detected that an Array Failed.

    May also be shown as 806f060d0407ffff or 0x806f060d0407ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0176
    User Response
    1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
    2. Make sure that the SAS cable is connected correctly.
    3. Replace the SAS cable.
    4. Replace the RAID adapter.
    5. Replace the hard disk drive that is indicated by a lit status LED.
  • 806f070c-2001ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2001ffff or 0x806f070c2001ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2002ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2002ffff or 0x806f070c2002ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2003ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2003ffff or 0x806f070c2003ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2004ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2004ffff or 0x806f070c2004ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2005ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2005ffff or 0x806f070c2005ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2006ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2006ffff or 0x806f070c2006ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2007ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2007ffff or 0x806f070c2007ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2008ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2008ffff or 0x806f070c2008ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2009ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2009ffff or 0x806f070c2009ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-200affff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c200affff or 0x806f070c200affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-200bffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c200bffff or 0x806f070c200bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-200cffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c200cffff or 0x806f070c200cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-200dffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c200dffff or 0x806f070c200dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-200effff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c200effff or 0x806f070c200effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-200fffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c200fffff or 0x806f070c200fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2010ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2010ffff or 0x806f070c2010ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2011ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2011ffff or 0x806f070c2011ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2012ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2012ffff or 0x806f070c2012ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2013ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2013ffff or 0x806f070c2013ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2014ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2014ffff or 0x806f070c2014ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2015ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2015ffff or 0x806f070c2015ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2016ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2016ffff or 0x806f070c2016ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2017ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2017ffff or 0x806f070c2017ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2018ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2018ffff or 0x806f070c2018ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication.
  • 806f070c-2581ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (All DIMMs)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected.

    May also be shown as 806f070c2581ffff or 0x806f070c2581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0126
    User Response
    Make sure that DIMMs are installed and following the memory population chart in the system publication. One of the DIMMs :
  • 806f070d-0400ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive 0)

    This message is for the use case when an implementation has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0400ffff or 0x806f070d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    No action; information only.
  • 806f070d-0401ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive 1)

    This message is for the use case when an implementation has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0401ffff or 0x806f070d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    No action; information only.
  • 806f070d-0402ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive 2)

    This message is for the use case when an implementation has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0402ffff or 0x806f070d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    No action; information only.
  • 806f070d-0403ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive 3)

    This message is for the use case when an implementation has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0403ffff or 0x806f070d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    No action; information only.
  • 806f070d-0404ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive 4)

    This message is for the use case when an implementation has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0404ffff or 0x806f070d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    No action; information only.
  • 806f070d-0405ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive 5)

    This message is for the use case when an implementation has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0405ffff or 0x806f070d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    No action; information only.
  • 806f070d-0406ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive 6)

    This message is for the use case when an implementation has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0406ffff or 0x806f070d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    No action; information only.
  • 806f070d-0407ffff : Rebuild in progress for Array in system [ComputerSystemElementName]. (Drive 7)

    This message is for the use case when an implementation has detected that an Array Rebuild is in Progress.

    May also be shown as 806f070d0407ffff or 0x806f070d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0178
    User Response
    No action; information only.
  • 806f072b-2101ffff : A successful software or firmware change was detected on system [ComputerSystemElementName]. (IMM Promotion)

    This message is for the use case when an implementation has detected a Successful Software or Firmware Change.

    May also be shown as 806f072b2101ffff or 0x806f072b2101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0450
    User Response
    No action; information only. IMM Recovery :
  • 806f072b-2201ffff : A successful software or firmware change was detected on system [ComputerSystemElementName]. (Bkup Auto Update)

    This message is for the use case when an implementation has detected a Successful Software or Firmware Change.

    May also be shown as 806f072b2201ffff or 0x806f072b2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0450
    User Response
    No action; information only. ROM Recovery :
  • 806f0807-0301ffff : [ProcessorElementName] has been Disabled. (CPU 1)

    This message is for the use case when an implementation has detected a Processor has been Disabled.

    May also be shown as 806f08070301ffff or 0x806f08070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0061
    User Response
    No action; information only.
  • 806f0807-0302ffff : [ProcessorElementName] has been Disabled. (CPU 2)

    This message is for the use case when an implementation has detected a Processor has been Disabled.

    May also be shown as 806f08070302ffff or 0x806f08070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0061
    User Response
    No action; information only.
  • 806f0807-2584ffff : [ProcessorElementName] has been Disabled. (All CPUs)

    This message is for the use case when an implementation has detected a Processor has been Disabled.

    May also be shown as 806f08072584ffff or 0x806f08072584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0061
    User Response
    No action; information only. One of CPUs :
  • 806f0813-2581ffff : An Uncorrectable Error has occurred on [SensorElementName]. (DIMMs)

    This message is for the use case when an implementation has detected a Bus Uncorrectable Error.

    May also be shown as 806f08132581ffff or 0x806f08132581ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0240
    User Response
    1. Check the system-event log.
    2. (Trained technician only) Remove the failing microprocessor from the system board (see Removing a microprocessor and heat sink).
    3. Check for a server firmware update. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    4. Make sure that the two microprocessors are matching.
    5. (Trained technician only) Replace the system board.
  • 806f0813-2584ffff : An Uncorrectable Error has occurred on [SensorElementName]. (CPUs)

    This message is for the use case when an implementation has detected a Bus Uncorrectable Error.

    May also be shown as 806f08132584ffff or 0x806f08132584ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    Yes
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0240
    User Response
    1. Check the system-event log.
    2. (Trained technician only) Remove the failing microprocessor from the system board (see Removing a microprocessor and heat sink).
    3. Check for a server firmware update. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
    4. Make sure that the two microprocessors are matching.
    5. (Trained technician only) Replace the system board.
  • 806f0823-2101ffff : Watchdog Timer interrupt occurred for [WatchdogElementName]. (IPMI Watchdog)

    This message is for the use case when an implementation has detected a Watchdog Timer interrupt occurred.

    May also be shown as 806f08232101ffff or 0x806f08232101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0376
    User Response
    No action; information only.
  • 806f090c-2001ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 1)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2001ffff or 0x806f090c2001ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2002ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 2)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2002ffff or 0x806f090c2002ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2003ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 3)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2003ffff or 0x806f090c2003ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2004ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 4)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2004ffff or 0x806f090c2004ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2005ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 5)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2005ffff or 0x806f090c2005ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2006ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 6)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2006ffff or 0x806f090c2006ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2007ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 7)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2007ffff or 0x806f090c2007ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2008ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 8)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2008ffff or 0x806f090c2008ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2009ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 9)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2009ffff or 0x806f090c2009ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-200affff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 10)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c200affff or 0x806f090c200affff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-200bffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 11)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c200bffff or 0x806f090c200bffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-200cffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 12)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c200cffff or 0x806f090c200cffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-200dffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 13)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c200dffff or 0x806f090c200dffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-200effff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 14)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c200effff or 0x806f090c200effff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-200fffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 15)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c200fffff or 0x806f090c200fffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2010ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 16)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2010ffff or 0x806f090c2010ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2011ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 17)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2011ffff or 0x806f090c2011ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2012ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 18)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2012ffff or 0x806f090c2012ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2013ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 19)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2013ffff or 0x806f090c2013ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2014ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 20)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2014ffff or 0x806f090c2014ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2015ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 21)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2015ffff or 0x806f090c2015ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2016ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 22)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2016ffff or 0x806f090c2016ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2017ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 23)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2017ffff or 0x806f090c2017ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f090c-2018ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. (DIMM 24)

    This message is for the use case when an implementation has detected Memory has been Throttled.

    May also be shown as 806f090c2018ffff or 0x806f090c2018ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    22
    CIM Information
    Prefix: PLAT ID: 0142
    User Response
    1. Reseat the DIMM, and then restart the server.
    2. Replace DIMM n. (n = DIMM number)
  • 806f0a07-0301ffff : [ProcessorElementName] is operating in a Degraded State. (CPU 1)

    This message is for the use case when an implementation has detected a Processor is running in the Degraded state.

    May also be shown as 806f0a070301ffff or 0x806f0a070301ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0038
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications.
    3. Make sure that the heat sink for microprocessor n is installed correctly.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 806f0a07-0302ffff : [ProcessorElementName] is operating in a Degraded State. (CPU 2)

    This message is for the use case when an implementation has detected a Processor is running in the Degraded state.

    May also be shown as 806f0a070302ffff or 0x806f0a070302ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0038
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications.
    3. Make sure that the heat sink for microprocessor n is installed correctly.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
  • 806f0a07-2584ffff : [ProcessorElementName] is operating in a Degraded State. (All CPUs)

    This message is for the use case when an implementation has detected a Processor is running in the Degraded state.

    May also be shown as 806f0a072584ffff or 0x806f0a072584ffff

    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0038
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Check the ambient temperature. You must be operating within the specifications.
    3. Make sure that the heat sink for microprocessor n is installed correctly.
    4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
    One of CPUs :
  • 806f0a0c-2001ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2001ffff or 0x806f0a0c2001ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2002ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2002ffff or 0x806f0a0c2002ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2003ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2003ffff or 0x806f0a0c2003ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2004ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2004ffff or 0x806f0a0c2004ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2005ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2005ffff or 0x806f0a0c2005ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2006ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2006ffff or 0x806f0a0c2006ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2007ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2007ffff or 0x806f0a0c2007ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2008ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2008ffff or 0x806f0a0c2008ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2009ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2009ffff or 0x806f0a0c2009ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-200affff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c200affff or 0x806f0a0c200affff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-200bffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c200bffff or 0x806f0a0c200bffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-200cffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c200cffff or 0x806f0a0c200cffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-200dffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c200dffff or 0x806f0a0c200dffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-200effff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c200effff or 0x806f0a0c200effff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-200fffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c200fffff or 0x806f0a0c200fffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2010ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2010ffff or 0x806f0a0c2010ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2011ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2011ffff or 0x806f0a0c2011ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2012ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2012ffff or 0x806f0a0c2012ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2013ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2013ffff or 0x806f0a0c2013ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2014ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2014ffff or 0x806f0a0c2014ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2015ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2015ffff or 0x806f0a0c2015ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2016ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2016ffff or 0x806f0a0c2016ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2017ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2017ffff or 0x806f0a0c2017ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a0c-2018ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.

    May also be shown as 806f0a0c2018ffff or 0x806f0a0c2018ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0146
    User Response
    1. Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
    2. Make sure that ambient temperature is within the specifications.
    3. If a fan has failed, complete the action for a fan failure.
    4. Replace DIMM n. (n = DIMM number)
  • 806f0a13-2401ffff : A Fatal Bus Error has occurred on bus [SensorElementName]. (SMBus)

    This message is for the use case when an implementation has detected a Bus Fatal Error.

    May also be shown as 806f0a132401ffff or 0x806f0a132401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0244
    User Response
    1. (Trained technician only)Reseat the microprocessor, and then restart the server.
    2. (Trained technician only)Replace microprocessor n. (n = microprocessor number)
  • 806f0a13-2582ffff : A Fatal Bus Error has occurred on bus [SensorElementName]. (All PCI Error)

    This message is for the use case when an implementation has detected a Bus Fatal Error.

    May also be shown as 806f0a132582ffff or 0x806f0a132582ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0244
    User Response
    1. (Trained technician only)Reseat the microprocessor, and then restart the server.
    2. (Trained technician only)Replace microprocessor n. (n = microprocessor number)
    One of PCI Error : PCIs :
  • 81010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted. (SysBrd 12V)

    This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted.

    May also be shown as 810102020701ffff or 0x810102020701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    No action; information only. SysBrd 3.3V : SysBrd 5V :
  • 81010202-2801ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has deasserted. (CMOS Battery)

    This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted.

    May also be shown as 810102022801ffff or 0x810102022801ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0481
    User Response
    No action; information only.
  • 81010701-3701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted. (Inlet Temp)

    This message is for the use case when an implementation has detected an Upper Non-critical sensor going high has deasserted.

    May also be shown as 810107013701ffff or 0x810107013701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0491
    User Response
    No action; information only.
  • 81010901-3701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted. (Inlet Temp)

    This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted.

    May also be shown as 810109013701ffff or 0x810109013701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    No action; information only.
  • 81010902-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has deasserted. (SysBrd 12V)

    This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted.

    May also be shown as 810109020701ffff or 0x810109020701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0495
    User Response
    No action; information only. SysBrd 3.3V : SysBrd 5V :
  • 81010b01-3701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted. (Inlet Temp)

    This message is for the use case when an implementation has detected an Upper Non-recoverable sensor going high has deasserted.

    May also be shown as 81010b013701ffff or 0x81010b013701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0499
    User Response
    No action; information only.
  • 81030006-2101ffff : Sensor [SensorElementName] has asserted. (Sig Verify Fail)

    This message is for the use case when an implementation has detected a Sensor has asserted.

    May also be shown as 810300062101ffff or 0x810300062101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    No action; information only.
  • 8103000f-2101ffff : Sensor [SensorElementName] has asserted. (IMM FW Corrupted)

    This message is for the use case when an implementation has detected a Sensor has asserted.

    May also be shown as 8103000f2101ffff or 0x8103000f2101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0508
    User Response
    No action; information only.
  • 8103010d-2b81ffff : Sensor [SensorElementName] has deasserted. (FDIMM Config)

    This message is for the use case when an implementation has detected a Sensor has deasserted.

    May also be shown as 8103010d2b81ffff or 0x8103010d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0509
    User Response
    No action; information only.
  • 8103010e-2581ffff : Sensor [SensorElementName] has deasserted. (Memory Resized)

    This message is for the use case when an implementation has detected a Sensor has deasserted.

    May also be shown as 8103010e2581ffff or 0x8103010e2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0509
    User Response
    No action; information only.
  • 81030112-0601ffff : Sensor [SensorElementName] has deasserted. (SMM Mode)

    This message is for the use case when an implementation has detected a Sensor has deasserted.

    May also be shown as 810301120601ffff or 0x810301120601ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0509
    User Response
    No action; information only. SMM Monitor :
  • 81030118-1701ffff : Sensor [SensorElementName] has deasserted. (Invalid NEBs Cfg)

    This message is for the use case when an implementation has detected a Sensor has deasserted.

    May also be shown as 810301181701ffff or 0x810301181701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0509
    User Response
    No action; information only.
  • 8105010d-2b81ffff : Sensor [SensorElementName] has indicated limit no longer exceeded. (FDIMM TempLimit)

    This message is for the use case when an implementation has detected a Sensor limit is no longer exceeded.

    May also be shown as 8105010d2b81ffff or 0x8105010d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0513
    User Response
    No action; information only.
  • 81070101-0301ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (CPU 1 Overtemp)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 810701010301ffff or 0x810701010301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 81070101-0302ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (CPU 2 Overtemp)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 810701010302ffff or 0x810701010302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 81070101-2c01ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (Mezz Exp 1 Temp)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 810701012c01ffff or 0x810701012c01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 81070101-2c02ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (Mezz Exp 2 Temp)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 810701012c02ffff or 0x810701012c02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 81070101-2c05ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (LOM Temp)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 810701012c05ffff or 0x810701012c05ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Temperature
    SNMP Trap ID
    12
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 8107010d-0b01ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (RAID #1 Volume)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 8107010d0b01ffff or 0x8107010d0b01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 8107010d-0b03ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (RAID #3 Volume)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 8107010d0b03ffff or 0x8107010d0b03ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 8107010d-2b81ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (FDIMM Warranty)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 8107010d2b81ffff or 0x8107010d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 8107010f-2201ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (GPT Status)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 8107010f2201ffff or 0x8107010f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 8107010f-2582ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (I/O Resources)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 8107010f2582ffff or 0x8107010f2582ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 81070112-0b01ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (RAID Warn Log)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 810701120b01ffff or 0x810701120b01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only.
  • 81070114-2201ffff : Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. (TPM Lock)

    This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non-critical from normal.

    May also be shown as 810701142201ffff or 0x810701142201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0521
    User Response
    No action; information only. TPM Phy Pres Set :
  • 81070201-2d01ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (PCH Overtemp)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 810702012d01ffff or 0x810702012d01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 81070202-0701ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (SysBrd Vol Fault)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 810702020701ffff or 0x810702020701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Voltage
    SNMP Trap ID
    1
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 8107020d-0b01ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (RAID #1 Volume)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 8107020d0b01ffff or 0x8107020d0b01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 8107020d-0b03ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (RAID #3 Volume)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 8107020d0b03ffff or 0x8107020d0b03ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 8107020d-2b81ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (FDIMM Warranty)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 8107020d2b81ffff or 0x8107020d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 8107020f-2201ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (TXT ACM Module)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 8107020f2201ffff or 0x8107020f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 8107020f-2582ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (I/O Resources)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 8107020f2582ffff or 0x8107020f2582ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 81070212-0b02ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (RAID Error Log)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 810702120b02ffff or 0x810702120b02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 81070217-2c01ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (M5115 Flt SCp)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 810702172c01ffff or 0x810702172c01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only. Mezz Exp 1 Fault :
  • 81070217-2c02ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (Mezz Exp 2 Fault)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 810702172c02ffff or 0x810702172c02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 81070219-0701ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (Sys Board Fault)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 810702190701ffff or 0x810702190701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 8107021b-0301ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (CPU 1 QPILinkErr)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 8107021b0301ffff or 0x8107021b0301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 8107021b-0302ffff : Sensor [SensorElementName] has transitioned to a less severe state from critical. (CPU 2 QPILinkErr)

    This message is for the use case when an implementation has detected a Sensor transition to less severe from critical.

    May also be shown as 8107021b0302ffff or 0x8107021b0302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0523
    User Response
    No action; information only.
  • 81070301-0301ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. (CPU 1 Overtemp)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.

    May also be shown as 810703010301ffff or 0x810703010301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    No action; information only.
  • 81070301-0302ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. (CPU 2 Overtemp)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.

    May also be shown as 810703010302ffff or 0x810703010302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    No action; information only.
  • 81070301-2c01ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. (Mezz Exp 1 Temp)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.

    May also be shown as 810703012c01ffff or 0x810703012c01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    No action; information only.
  • 81070301-2c02ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. (Mezz Exp 2 Temp)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.

    May also be shown as 810703012c02ffff or 0x810703012c02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    No action; information only.
  • 81070301-2c05ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. (LOM Temp)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.

    May also be shown as 810703012c05ffff or 0x810703012c05ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    No action; information only.
  • 81070301-2d01ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. (PCH Overtemp)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.

    May also be shown as 810703012d01ffff or 0x810703012d01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    No action; information only.
  • 8107030d-0b01ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. (RAID #1 Volume)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.

    May also be shown as 8107030d0b01ffff or 0x8107030d0b01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    No action; information only.
  • 8107030d-0b03ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. (RAID #3 Volume)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.

    May also be shown as 8107030d0b03ffff or 0x8107030d0b03ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    No action; information only.
  • 8107030d-2b81ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. (FDIMM Warranty)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable from less severe has deasserted.

    May also be shown as 8107030d2b81ffff or 0x8107030d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0525
    User Response
    No action; information only.
  • 81070601-2c01ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable. (Mezz Exp 1 Temp)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable has deasserted.

    May also be shown as 810706012c01ffff or 0x810706012c01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    No action; information only.
  • 81070601-2c02ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable. (Mezz Exp 2 Temp)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable has deasserted.

    May also be shown as 810706012c02ffff or 0x810706012c02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    No action; information only.
  • 81070601-2c05ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable. (LOM Temp)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable has deasserted.

    May also be shown as 810706012c05ffff or 0x810706012c05ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    No action; information only.
  • 8107060f-2201ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable. (BOFM Config Err)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable has deasserted.

    May also be shown as 8107060f2201ffff or 0x8107060f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    No action; information only.
  • 81070614-2201ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable. (TPM Phy Pres Set)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable has deasserted.

    May also be shown as 810706142201ffff or 0x810706142201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    No action; information only.
  • 81070617-2c01ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable. (Mezz Exp 1 Fault)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable has deasserted.

    May also be shown as 810706172c01ffff or 0x810706172c01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    No action; information only.
  • 81070617-2c02ffff : Sensor [SensorElementName] has deasserted the transition to non-recoverable. (Mezz Exp 2 Fault)

    This message is for the use case when an implementation has detected that the Sensor transition to non-recoverable has deasserted.

    May also be shown as 810706172c02ffff or 0x810706172c02ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0531
    User Response
    No action; information only.
  • 81080017-0f01ffff : Device [LogicalDeviceElementName] has been added. (SAS BP)

    This message is for the use case when an implementation has detected a Device was inserted.

    May also be shown as 810800170f01ffff or 0x810800170f01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0536
    User Response
    No action; information only.
  • 81090112-2101ffff : Device [LogicalDeviceElementName] has been disabled. (IPMI/SNMP Accts)

    This message is for the use case when an implementation has detected a Device was disabled.

    May also be shown as 810901122101ffff or 0x810901122101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0539
    User Response
    No action; information only.
  • 810b010c-2581ffff : Redundancy Lost for [RedundancySetElementName] has deasserted. (Backup Memory)

    This message is for the use case when Redundacy Lost has deasserted.

    May also be shown as 810b010c2581ffff or 0x810b010c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0803
    User Response
    No action; information only.
  • 810b030c-2581ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has deasserted. (Backup Memory)

    This message is for the use case when a Redundancy Set has transitioned from Non-redundant:Sufficient Resources.

    May also be shown as 810b030c2581ffff or 0x810b030c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0807
    User Response
    No action; information only.
  • 810b050c-2581ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has deasserted. (Backup Memory)

    This message is for the use case when a Redundancy Set has transitioned from Non-redundant:Insufficient Resources.

    May also be shown as 810b050c2581ffff or 0x810b050c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0811
    User Response
    No action; information only.
  • 816f0007-0301ffff : [ProcessorElementName] has Recovered from IERR. (CPU 1)

    This message is for the use case when an implementation has detected a Processor Recovered - IERR Condition.

    May also be shown as 816f00070301ffff or 0x816f00070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0043
    User Response
    No action; information only.
  • 816f0007-0302ffff : [ProcessorElementName] has Recovered from IERR. (CPU 2)

    This message is for the use case when an implementation has detected a Processor Recovered - IERR Condition.

    May also be shown as 816f00070302ffff or 0x816f00070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0043
    User Response
    No action; information only.
  • 816f0007-2584ffff : [ProcessorElementName] has Recovered from IERR. (All CPUs)

    This message is for the use case when an implementation has detected a Processor Recovered - IERR Condition.

    May also be shown as 816f00072584ffff or 0x816f00072584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0043
    User Response
    No action; information only. One of CPUs :
  • 816f0009-0701ffff : [PowerSupplyElementName] has been turned on. (Host Power)

    This message is for the use case when an implementation has detected a Power Unit that has been Enabled.

    May also be shown as 816f00090701ffff or 0x816f00090701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Power On
    SNMP Trap ID
    24
    CIM Information
    Prefix: PLAT ID: 0107
    User Response
    No action; information only.
  • 816f000d-0400ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 0)

    This message is for the use case when an implementation has detected a Drive has been Removed.

    May also be shown as 816f000d0400ffff or 0x816f000d0400ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
    2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
    3. Check the SAS cable.
    4. Replace the hard disk drive.
  • 816f000d-0401ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 1)

    This message is for the use case when an implementation has detected a Drive has been Removed.

    May also be shown as 816f000d0401ffff or 0x816f000d0401ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
    2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
    3. Check the SAS cable.
    4. Replace the hard disk drive.
  • 816f000d-0402ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 2)

    This message is for the use case when an implementation has detected a Drive has been Removed.

    May also be shown as 816f000d0402ffff or 0x816f000d0402ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
    2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
    3. Check the SAS cable.
    4. Replace the hard disk drive.
  • 816f000d-0403ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 3)

    This message is for the use case when an implementation has detected a Drive has been Removed.

    May also be shown as 816f000d0403ffff or 0x816f000d0403ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
    2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
    3. Check the SAS cable.
    4. Replace the hard disk drive.
  • 816f000d-0404ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 4)

    This message is for the use case when an implementation has detected a Drive has been Removed.

    May also be shown as 816f000d0404ffff or 0x816f000d0404ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
    2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
    3. Check the SAS cable.
    4. Replace the hard disk drive.
  • 816f000d-0405ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 5)

    This message is for the use case when an implementation has detected a Drive has been Removed.

    May also be shown as 816f000d0405ffff or 0x816f000d0405ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
    2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
    3. Check the SAS cable.
    4. Replace the hard disk drive.
  • 816f000d-0406ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 6)

    This message is for the use case when an implementation has detected a Drive has been Removed.

    May also be shown as 816f000d0406ffff or 0x816f000d0406ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
    2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
    3. Check the SAS cable.
    4. Replace the hard disk drive.
  • 816f000d-0407ffff : The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. (Drive 7)

    This message is for the use case when an implementation has detected a Drive has been Removed.

    May also be shown as 816f000d0407ffff or 0x816f000d0407ffff

    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0163
    User Response
    1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
    2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level.
    3. Check the SAS cable.
    4. Replace the hard disk drive.
  • 816f000f-2201ffff : The System [ComputerSystemElementName] has detected a POST Error deassertion. (ABR Status)

    This message is for the use case when an implementation has detected that Post Error has deasserted.

    May also be shown as 816f000f2201ffff or 0x816f000f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0185
    User Response
    No action; information only. Firmware Error : Sys Boot Status :
  • 816f0013-1701ffff : System [ComputerSystemElementName] has recovered from a diagnostic interrupt. (NMI State)

    This message is for the use case when an implementation has detected a recovery from a Front Panel NMI / Diagnostic Interrupt

    May also be shown as 816f00131701ffff or 0x816f00131701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0223
    User Response
    No action; information only.
  • 816f0021-2201ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName]. (No Op ROM Space)

    This message is for the use case when an implementation has detected a Fault condition in a slot has been removed.

    May also be shown as 816f00212201ffff or 0x816f00212201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    No action; information only.
  • 816f0021-2582ffff : Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName]. (PCIe Error)

    This message is for the use case when an implementation has detected a Fault condition in a slot has been removed.

    May also be shown as 816f00212582ffff or 0x816f00212582ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0331
    User Response
    No action; information only.
  • 816f0028-2101ffff : Sensor [SensorElementName] has returned to normal on management system [ComputerSystemElementName]. (TPM Cmd Failures)

    This message is for the use case when an implementation has detected a Sensor returned from degraded/unavailable/failure.

    May also be shown as 816f00282101ffff or 0x816f00282101ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Other
    SNMP Trap ID
    60
    CIM Information
    Prefix: PLAT ID: 0399
    User Response
    No action; information only.
  • 816f0107-0301ffff : An Over-Temperature Condition has been removed on [ProcessorElementName]. (CPU 1)

    This message is for the use case when an implementation has detected a Over-Temperature Condition has been Removed for Processor.

    May also be shown as 816f01070301ffff or 0x816f01070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0037
    User Response
    No action; information only.
  • 816f0107-0302ffff : An Over-Temperature Condition has been removed on [ProcessorElementName]. (CPU 2)

    This message is for the use case when an implementation has detected a Over-Temperature Condition has been Removed for Processor.

    May also be shown as 816f01070302ffff or 0x816f01070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0037
    User Response
    No action; information only.
  • 816f0107-2584ffff : An Over-Temperature Condition has been removed on [ProcessorElementName]. (All CPUs)

    This message is for the use case when an implementation has detected a Over-Temperature Condition has been Removed for Processor.

    May also be shown as 816f01072584ffff or 0x816f01072584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0037
    User Response
    No action; information only. One of CPUs :
  • 816f010c-2001ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2001ffff or 0x816f010c2001ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2002ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2002ffff or 0x816f010c2002ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2003ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2003ffff or 0x816f010c2003ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2004ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2004ffff or 0x816f010c2004ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2005ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2005ffff or 0x816f010c2005ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2006ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2006ffff or 0x816f010c2006ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2007ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2007ffff or 0x816f010c2007ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2008ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2008ffff or 0x816f010c2008ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2009ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2009ffff or 0x816f010c2009ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-200affff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c200affff or 0x816f010c200affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-200bffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c200bffff or 0x816f010c200bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-200cffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c200cffff or 0x816f010c200cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-200dffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c200dffff or 0x816f010c200dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-200effff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c200effff or 0x816f010c200effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-200fffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c200fffff or 0x816f010c200fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2010ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2010ffff or 0x816f010c2010ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2011ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2011ffff or 0x816f010c2011ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2012ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2012ffff or 0x816f010c2012ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2013ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2013ffff or 0x816f010c2013ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2014ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2014ffff or 0x816f010c2014ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2015ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2015ffff or 0x816f010c2015ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2016ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2016ffff or 0x816f010c2016ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2017ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2017ffff or 0x816f010c2017ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2018ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2018ffff or 0x816f010c2018ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only.
  • 816f010c-2581ffff : Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (All DIMMs)

    This message is for the use case when an implementation has detected a Memory uncorrectable error recovery.

    May also be shown as 816f010c2581ffff or 0x816f010c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0139
    User Response
    No action; information only. One of the DIMMs :
  • 816f010d-0400ffff : The [StorageVolumeElementName] has been enabled. (Drive 0)

    This message is for the use case when an implementation has detected a Drive was Enabled.

    May also be shown as 816f010d0400ffff or 0x816f010d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    No action; information only.
  • 816f010d-0401ffff : The [StorageVolumeElementName] has been enabled. (Drive 1)

    This message is for the use case when an implementation has detected a Drive was Enabled.

    May also be shown as 816f010d0401ffff or 0x816f010d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    No action; information only.
  • 816f010d-0402ffff : The [StorageVolumeElementName] has been enabled. (Drive 2)

    This message is for the use case when an implementation has detected a Drive was Enabled.

    May also be shown as 816f010d0402ffff or 0x816f010d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    No action; information only.
  • 816f010d-0403ffff : The [StorageVolumeElementName] has been enabled. (Drive 3)

    This message is for the use case when an implementation has detected a Drive was Enabled.

    May also be shown as 816f010d0403ffff or 0x816f010d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    No action; information only.
  • 816f010d-0404ffff : The [StorageVolumeElementName] has been enabled. (Drive 4)

    This message is for the use case when an implementation has detected a Drive was Enabled.

    May also be shown as 816f010d0404ffff or 0x816f010d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    No action; information only.
  • 816f010d-0405ffff : The [StorageVolumeElementName] has been enabled. (Drive 5)

    This message is for the use case when an implementation has detected a Drive was Enabled.

    May also be shown as 816f010d0405ffff or 0x816f010d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    No action; information only.
  • 816f010d-0406ffff : The [StorageVolumeElementName] has been enabled. (Drive 6)

    This message is for the use case when an implementation has detected a Drive was Enabled.

    May also be shown as 816f010d0406ffff or 0x816f010d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    No action; information only.
  • 816f010d-0407ffff : The [StorageVolumeElementName] has been enabled. (Drive 7)

    This message is for the use case when an implementation has detected a Drive was Enabled.

    May also be shown as 816f010d0407ffff or 0x816f010d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    No action; information only.
  • 816f010d-2b81ffff : The [StorageVolumeElementName] has been enabled. (FDIMM Stat)

    This message is for the use case when an implementation has detected a Drive was Enabled.

    May also be shown as 816f010d2b81ffff or 0x816f010d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0167
    User Response
    No action; information only.
  • 816f010f-2201ffff : The System [ComputerSystemElementName] has recovered from a firmware hang. (Firmware Error)

    This message is for the use case when an implementation has recovered from a System Firmware Hang.

    May also be shown as 816f010f2201ffff or 0x816f010f2201ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0187
    User Response
    No action; information only.
  • 816f011b-0c01ffff : The connector [PhysicalConnectorElementName] configuration error has been repaired. (LightPath)

    This message is for the use case when an implementation has detected an Interconnect Configuration was Repaired.

    May also be shown as 816f011b0c01ffff or 0x816f011b0c01ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0267
    User Response
    No action; information only.
  • 816f0125-1f05ffff : [ManagedElementName] detected as present. (LOM)

    This message is for the use case when an implementation has detected a Managed Element is now Present.

    May also be shown as 816f01251f05ffff or 0x816f01251f05ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0390
    User Response
    No action; information only.
  • 816f0207-0301ffff : [ProcessorElementName] has Recovered from FRB1/BIST condition. (CPU 1)

    This message is for the use case when an implementation has detected a Processor Recovered - FRB1/BIST condition.

    May also be shown as 816f02070301ffff or 0x816f02070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0045
    User Response
    No action; information only.
  • 816f0207-0302ffff : [ProcessorElementName] has Recovered from FRB1/BIST condition. (CPU 2)

    This message is for the use case when an implementation has detected a Processor Recovered - FRB1/BIST condition.

    May also be shown as 816f02070302ffff or 0x816f02070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0045
    User Response
    No action; information only.
  • 816f0207-2584ffff : [ProcessorElementName] has Recovered from FRB1/BIST condition. (All CPUs)

    This message is for the use case when an implementation has detected a Processor Recovered - FRB1/BIST condition.

    May also be shown as 816f02072584ffff or 0x816f02072584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0045
    User Response
    No action; information only. One of CPUs :
  • 816f020d-0400ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 0)

    This message is for the use case when an implementation has detected an Array Failure is no longer Predicted.

    May also be shown as 816f020d0400ffff or 0x816f020d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    No action; information only.
  • 816f020d-0401ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 1)

    This message is for the use case when an implementation has detected an Array Failure is no longer Predicted.

    May also be shown as 816f020d0401ffff or 0x816f020d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    No action; information only.
  • 816f020d-0402ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 2)

    This message is for the use case when an implementation has detected an Array Failure is no longer Predicted.

    May also be shown as 816f020d0402ffff or 0x816f020d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    No action; information only.
  • 816f020d-0403ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 3)

    This message is for the use case when an implementation has detected an Array Failure is no longer Predicted.

    May also be shown as 816f020d0403ffff or 0x816f020d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    No action; information only.
  • 816f020d-0404ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 4)

    This message is for the use case when an implementation has detected an Array Failure is no longer Predicted.

    May also be shown as 816f020d0404ffff or 0x816f020d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    No action; information only.
  • 816f020d-0405ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 5)

    This message is for the use case when an implementation has detected an Array Failure is no longer Predicted.

    May also be shown as 816f020d0405ffff or 0x816f020d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    No action; information only.
  • 816f020d-0406ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 6)

    This message is for the use case when an implementation has detected an Array Failure is no longer Predicted.

    May also be shown as 816f020d0406ffff or 0x816f020d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    No action; information only.
  • 816f020d-0407ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Drive 7)

    This message is for the use case when an implementation has detected an Array Failure is no longer Predicted.

    May also be shown as 816f020d0407ffff or 0x816f020d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    No action; information only.
  • 816f020d-2b81ffff : Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (FDIMM Stat)

    This message is for the use case when an implementation has detected an Array Failure is no longer Predicted.

    May also be shown as 816f020d2b81ffff or 0x816f020d2b81ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Predicted Failure
    SNMP Trap ID
    27
    CIM Information
    Prefix: PLAT ID: 0169
    User Response
    No action; information only.
  • 816f030c-2001ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 1)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2001ffff or 0x816f030c2001ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2002ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 2)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2002ffff or 0x816f030c2002ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2003ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 3)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2003ffff or 0x816f030c2003ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2004ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 4)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2004ffff or 0x816f030c2004ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2005ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 5)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2005ffff or 0x816f030c2005ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2006ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 6)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2006ffff or 0x816f030c2006ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2007ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 7)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2007ffff or 0x816f030c2007ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2008ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 8)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2008ffff or 0x816f030c2008ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2009ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 9)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2009ffff or 0x816f030c2009ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-200affff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 10)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c200affff or 0x816f030c200affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-200bffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 11)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c200bffff or 0x816f030c200bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-200cffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 12)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c200cffff or 0x816f030c200cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-200dffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 13)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c200dffff or 0x816f030c200dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-200effff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 14)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c200effff or 0x816f030c200effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-200fffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 15)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c200fffff or 0x816f030c200fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2010ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 16)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2010ffff or 0x816f030c2010ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2011ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 17)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2011ffff or 0x816f030c2011ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2012ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 18)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2012ffff or 0x816f030c2012ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2013ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 19)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2013ffff or 0x816f030c2013ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2014ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 20)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2014ffff or 0x816f030c2014ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2015ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 21)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2015ffff or 0x816f030c2015ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2016ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 22)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2016ffff or 0x816f030c2016ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2017ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 23)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2017ffff or 0x816f030c2017ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2018ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (DIMM 24)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2018ffff or 0x816f030c2018ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only.
  • 816f030c-2581ffff : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. (All DIMMs)

    This message is for the use case when an implementation has detected a Memory Scrub failure recovery.

    May also be shown as 816f030c2581ffff or 0x816f030c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0137
    User Response
    No action; information only. One of the DIMMs :
  • 816f030d-0400ffff : Hot spare disabled for [ComputerSystemElementName]. (Drive 0)

    This message is for the use case when an implementation has detected a Hot Spare has been Disabled.

    May also be shown as 816f030d0400ffff or 0x816f030d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0171
    User Response
    No action; information only.
  • 816f030d-0401ffff : Hot spare disabled for [ComputerSystemElementName]. (Drive 1)

    This message is for the use case when an implementation has detected a Hot Spare has been Disabled.

    May also be shown as 816f030d0401ffff or 0x816f030d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0171
    User Response
    No action; information only.
  • 816f030d-0402ffff : Hot spare disabled for [ComputerSystemElementName]. (Drive 2)

    This message is for the use case when an implementation has detected a Hot Spare has been Disabled.

    May also be shown as 816f030d0402ffff or 0x816f030d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0171
    User Response
    No action; information only.
  • 816f030d-0403ffff : Hot spare disabled for [ComputerSystemElementName]. (Drive 3)

    This message is for the use case when an implementation has detected a Hot Spare has been Disabled.

    May also be shown as 816f030d0403ffff or 0x816f030d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0171
    User Response
    No action; information only.
  • 816f030d-0404ffff : Hot spare disabled for [ComputerSystemElementName]. (Drive 4)

    This message is for the use case when an implementation has detected a Hot Spare has been Disabled.

    May also be shown as 816f030d0404ffff or 0x816f030d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0171
    User Response
    No action; information only.
  • 816f030d-0405ffff : Hot spare disabled for [ComputerSystemElementName]. (Drive 5)

    This message is for the use case when an implementation has detected a Hot Spare has been Disabled.

    May also be shown as 816f030d0405ffff or 0x816f030d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0171
    User Response
    No action; information only.
  • 816f030d-0406ffff : Hot spare disabled for [ComputerSystemElementName]. (Drive 6)

    This message is for the use case when an implementation has detected a Hot Spare has been Disabled.

    May also be shown as 816f030d0406ffff or 0x816f030d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0171
    User Response
    No action; information only.
  • 816f030d-0407ffff : Hot spare disabled for [ComputerSystemElementName]. (Drive 7)

    This message is for the use case when an implementation has detected a Hot Spare has been Disabled.

    May also be shown as 816f030d0407ffff or 0x816f030d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0171
    User Response
    No action; information only.
  • 816f0313-1701ffff : System [ComputerSystemElementName] has recovered from an NMI. (NMI State)

    This message is for the use case when an implementation has detected a Software NMI has been Recovered from.

    May also be shown as 816f03131701ffff or 0x816f03131701ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0230
    User Response
    No action; information only.
  • 816f040c-2001ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2001ffff or 0x816f040c2001ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2002ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2002ffff or 0x816f040c2002ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2003ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2003ffff or 0x816f040c2003ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2004ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2004ffff or 0x816f040c2004ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2005ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2005ffff or 0x816f040c2005ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2006ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2006ffff or 0x816f040c2006ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2007ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2007ffff or 0x816f040c2007ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2008ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2008ffff or 0x816f040c2008ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2009ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2009ffff or 0x816f040c2009ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-200affff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c200affff or 0x816f040c200affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-200bffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c200bffff or 0x816f040c200bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-200cffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c200cffff or 0x816f040c200cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-200dffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c200dffff or 0x816f040c200dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-200effff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c200effff or 0x816f040c200effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-200fffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c200fffff or 0x816f040c200fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2010ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2010ffff or 0x816f040c2010ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2011ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2011ffff or 0x816f040c2011ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2012ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2012ffff or 0x816f040c2012ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2013ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2013ffff or 0x816f040c2013ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2014ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2014ffff or 0x816f040c2014ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2015ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2015ffff or 0x816f040c2015ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2016ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2016ffff or 0x816f040c2016ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2017ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2017ffff or 0x816f040c2017ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2018ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2018ffff or 0x816f040c2018ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only.
  • 816f040c-2581ffff : [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. (All DIMMs)

    This message is for the use case when an implementation has detected that Memory has been Enabled.

    May also be shown as 816f040c2581ffff or 0x816f040c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0130
    User Response
    No action; information only. One of the DIMMs :
  • 816f0413-2582ffff : A PCI PERR recovery has occurred on system [ComputerSystemElementName]. (All PCI Error)

    This message is for the use case when an implementation has detected a PCI PERR recovered.

    May also be shown as 816f04132582ffff or 0x816f04132582ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0233
    User Response
    No action; information only. One of PCI Error : PCIs :
  • 816f0507-0301ffff : [ProcessorElementName] has Recovered from a Configuration Mismatch. (CPU 1)

    This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch.

    May also be shown as 816f05070301ffff or 0x816f05070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0063
    User Response
    No action; information only.
  • 816f0507-0302ffff : [ProcessorElementName] has Recovered from a Configuration Mismatch. (CPU 2)

    This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch.

    May also be shown as 816f05070302ffff or 0x816f05070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0063
    User Response
    No action; information only.
  • 816f0507-2584ffff : [ProcessorElementName] has Recovered from a Configuration Mismatch. (All CPUs)

    This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch.

    May also be shown as 816f05072584ffff or 0x816f05072584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0063
    User Response
    No action; information only. One of CPUs :
  • 816f050c-2001ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2001ffff or 0x816f050c2001ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2002ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2002ffff or 0x816f050c2002ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2003ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2003ffff or 0x816f050c2003ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2004ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2004ffff or 0x816f050c2004ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2005ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2005ffff or 0x816f050c2005ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2006ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2006ffff or 0x816f050c2006ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2007ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2007ffff or 0x816f050c2007ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2008ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2008ffff or 0x816f050c2008ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2009ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2009ffff or 0x816f050c2009ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-200affff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c200affff or 0x816f050c200affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-200bffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c200bffff or 0x816f050c200bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-200cffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c200cffff or 0x816f050c200cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-200dffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c200dffff or 0x816f050c200dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-200effff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c200effff or 0x816f050c200effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-200fffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c200fffff or 0x816f050c200fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2010ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2010ffff or 0x816f050c2010ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2011ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2011ffff or 0x816f050c2011ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2012ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2012ffff or 0x816f050c2012ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2013ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2013ffff or 0x816f050c2013ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2014ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2014ffff or 0x816f050c2014ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2015ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2015ffff or 0x816f050c2015ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2016ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2016ffff or 0x816f050c2016ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2017ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2017ffff or 0x816f050c2017ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2018ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2018ffff or 0x816f050c2018ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only.
  • 816f050c-2581ffff : Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (All DIMMs)

    This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed.

    May also be shown as 816f050c2581ffff or 0x816f050c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - Memory
    SNMP Trap ID
    43
    CIM Information
    Prefix: PLAT ID: 0145
    User Response
    No action; information only. One of the DIMMs :
  • 816f050d-0400ffff : Critical Array [ComputerSystemElementName] has deasserted. (Drive 0)

    This message is for the use case when an implementation has detected that an Critiacal Array has deasserted.

    May also be shown as 816f050d0400ffff or 0x816f050d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    No action; information only.
  • 816f050d-0401ffff : Critical Array [ComputerSystemElementName] has deasserted. (Drive 1)

    This message is for the use case when an implementation has detected that an Critiacal Array has deasserted.

    May also be shown as 816f050d0401ffff or 0x816f050d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    No action; information only.
  • 816f050d-0402ffff : Critical Array [ComputerSystemElementName] has deasserted. (Drive 2)

    This message is for the use case when an implementation has detected that an Critiacal Array has deasserted.

    May also be shown as 816f050d0402ffff or 0x816f050d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    No action; information only.
  • 816f050d-0403ffff : Critical Array [ComputerSystemElementName] has deasserted. (Drive 3)

    This message is for the use case when an implementation has detected that an Critiacal Array has deasserted.

    May also be shown as 816f050d0403ffff or 0x816f050d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    No action; information only.
  • 816f050d-0404ffff : Critical Array [ComputerSystemElementName] has deasserted. (Drive 4)

    This message is for the use case when an implementation has detected that an Critiacal Array has deasserted.

    May also be shown as 816f050d0404ffff or 0x816f050d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    No action; information only.
  • 816f050d-0405ffff : Critical Array [ComputerSystemElementName] has deasserted. (Drive 5)

    This message is for the use case when an implementation has detected that an Critiacal Array has deasserted.

    May also be shown as 816f050d0405ffff or 0x816f050d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    No action; information only.
  • 816f050d-0406ffff : Critical Array [ComputerSystemElementName] has deasserted. (Drive 6)

    This message is for the use case when an implementation has detected that an Critiacal Array has deasserted.

    May also be shown as 816f050d0406ffff or 0x816f050d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    No action; information only.
  • 816f050d-0407ffff : Critical Array [ComputerSystemElementName] has deasserted. (Drive 7)

    This message is for the use case when an implementation has detected that an Critiacal Array has deasserted.

    May also be shown as 816f050d0407ffff or 0x816f050d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0175
    User Response
    No action; information only.
  • 816f0607-0301ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has deasserted. (CPU 1)

    This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted.

    May also be shown as 816f06070301ffff or 0x816f06070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0817
    User Response
    No action; information only.
  • 816f0607-0302ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has deasserted. (CPU 2)

    This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted.

    May also be shown as 816f06070302ffff or 0x816f06070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0817
    User Response
    No action; information only.
  • 816f0607-2584ffff : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has deasserted. (All CPUs)

    This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted.

    May also be shown as 816f06072584ffff or 0x816f06072584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - CPU
    SNMP Trap ID
    40
    CIM Information
    Prefix: PLAT ID: 0817
    User Response
    No action; information only. One of CPUs :
  • 816f060d-0400ffff : Array in system [ComputerSystemElementName] has been restored. (Drive 0)

    This message is for the use case when an implementation has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0400ffff or 0x816f060d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    No action; information only.
  • 816f060d-0401ffff : Array in system [ComputerSystemElementName] has been restored. (Drive 1)

    This message is for the use case when an implementation has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0401ffff or 0x816f060d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    No action; information only.
  • 816f060d-0402ffff : Array in system [ComputerSystemElementName] has been restored. (Drive 2)

    This message is for the use case when an implementation has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0402ffff or 0x816f060d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    No action; information only.
  • 816f060d-0403ffff : Array in system [ComputerSystemElementName] has been restored. (Drive 3)

    This message is for the use case when an implementation has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0403ffff or 0x816f060d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    No action; information only.
  • 816f060d-0404ffff : Array in system [ComputerSystemElementName] has been restored. (Drive 4)

    This message is for the use case when an implementation has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0404ffff or 0x816f060d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    No action; information only.
  • 816f060d-0405ffff : Array in system [ComputerSystemElementName] has been restored. (Drive 5)

    This message is for the use case when an implementation has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0405ffff or 0x816f060d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    No action; information only.
  • 816f060d-0406ffff : Array in system [ComputerSystemElementName] has been restored. (Drive 6)

    This message is for the use case when an implementation has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0406ffff or 0x816f060d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    No action; information only.
  • 816f060d-0407ffff : Array in system [ComputerSystemElementName] has been restored. (Drive 7)

    This message is for the use case when an implementation has detected that a Failed Array has been Restored.

    May also be shown as 816f060d0407ffff or 0x816f060d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Hard Disk drive
    SNMP Trap ID
    5
    CIM Information
    Prefix: PLAT ID: 0177
    User Response
    No action; information only.
  • 816f070c-2001ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 1)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2001ffff or 0x816f070c2001ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2002ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 2)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2002ffff or 0x816f070c2002ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2003ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 3)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2003ffff or 0x816f070c2003ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2004ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 4)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2004ffff or 0x816f070c2004ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2005ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 5)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2005ffff or 0x816f070c2005ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2006ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 6)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2006ffff or 0x816f070c2006ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2007ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 7)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2007ffff or 0x816f070c2007ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2008ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 8)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2008ffff or 0x816f070c2008ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2009ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 9)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2009ffff or 0x816f070c2009ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-200affff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 10)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c200affff or 0x816f070c200affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-200bffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 11)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c200bffff or 0x816f070c200bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-200cffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 12)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c200cffff or 0x816f070c200cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-200dffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 13)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c200dffff or 0x816f070c200dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-200effff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 14)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c200effff or 0x816f070c200effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-200fffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 15)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c200fffff or 0x816f070c200fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2010ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 16)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2010ffff or 0x816f070c2010ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2011ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 17)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2011ffff or 0x816f070c2011ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2012ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 18)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2012ffff or 0x816f070c2012ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2013ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 19)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2013ffff or 0x816f070c2013ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2014ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 20)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2014ffff or 0x816f070c2014ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2015ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 21)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2015ffff or 0x816f070c2015ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2016ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 22)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2016ffff or 0x816f070c2016ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2017ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 23)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2017ffff or 0x816f070c2017ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2018ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (DIMM 24)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2018ffff or 0x816f070c2018ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only.
  • 816f070c-2581ffff : Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. (All DIMMs)

    This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted.

    May also be shown as 816f070c2581ffff or 0x816f070c2581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Memory
    SNMP Trap ID
    41
    CIM Information
    Prefix: PLAT ID: 0127
    User Response
    No action; information only. One of the DIMMs :
  • 816f070d-0400ffff : Rebuild completed for Array in system [ComputerSystemElementName]. (Drive 0)

    This message is for the use case when an implementation has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0400ffff or 0x816f070d0400ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    No action; information only.
  • 816f070d-0401ffff : Rebuild completed for Array in system [ComputerSystemElementName]. (Drive 1)

    This message is for the use case when an implementation has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0401ffff or 0x816f070d0401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    No action; information only.
  • 816f070d-0402ffff : Rebuild completed for Array in system [ComputerSystemElementName]. (Drive 2)

    This message is for the use case when an implementation has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0402ffff or 0x816f070d0402ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    No action; information only.
  • 816f070d-0403ffff : Rebuild completed for Array in system [ComputerSystemElementName]. (Drive 3)

    This message is for the use case when an implementation has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0403ffff or 0x816f070d0403ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    No action; information only.
  • 816f070d-0404ffff : Rebuild completed for Array in system [ComputerSystemElementName]. (Drive 4)

    This message is for the use case when an implementation has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0404ffff or 0x816f070d0404ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    No action; information only.
  • 816f070d-0405ffff : Rebuild completed for Array in system [ComputerSystemElementName]. (Drive 5)

    This message is for the use case when an implementation has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0405ffff or 0x816f070d0405ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    No action; information only.
  • 816f070d-0406ffff : Rebuild completed for Array in system [ComputerSystemElementName]. (Drive 6)

    This message is for the use case when an implementation has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0406ffff or 0x816f070d0406ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    No action; information only.
  • 816f070d-0407ffff : Rebuild completed for Array in system [ComputerSystemElementName]. (Drive 7)

    This message is for the use case when an implementation has detected that an Array Rebuild has Completed.

    May also be shown as 816f070d0407ffff or 0x816f070d0407ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0179
    User Response
    No action; information only.
  • 816f0807-0301ffff : [ProcessorElementName] has been Enabled. (CPU 1)

    This message is for the use case when an implementation has detected a Processor has been Enabled.

    May also be shown as 816f08070301ffff or 0x816f08070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0060
    User Response
    No action; information only.
  • 816f0807-0302ffff : [ProcessorElementName] has been Enabled. (CPU 2)

    This message is for the use case when an implementation has detected a Processor has been Enabled.

    May also be shown as 816f08070302ffff or 0x816f08070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0060
    User Response
    No action; information only.
  • 816f0807-2584ffff : [ProcessorElementName] has been Enabled. (All CPUs)

    This message is for the use case when an implementation has detected a Processor has been Enabled.

    May also be shown as 816f08072584ffff or 0x816f08072584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0060
    User Response
    No action; information only. One of CPUs :
  • 816f0813-2581ffff : Bus [SensorElementName] has recovered from an Uncorrectable Error. (DIMMs)

    This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error.

    May also be shown as 816f08132581ffff or 0x816f08132581ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0241
    User Response
    No action; information only.
  • 816f0813-2584ffff : Bus [SensorElementName] has recovered from an Uncorrectable Error. (CPUs)

    This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error.

    May also be shown as 816f08132584ffff or 0x816f08132584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0241
    User Response
    No action; information only.
  • 816f090c-2001ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 1)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2001ffff or 0x816f090c2001ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2002ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 2)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2002ffff or 0x816f090c2002ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2003ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 3)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2003ffff or 0x816f090c2003ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2004ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 4)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2004ffff or 0x816f090c2004ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2005ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 5)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2005ffff or 0x816f090c2005ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2006ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 6)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2006ffff or 0x816f090c2006ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2007ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 7)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2007ffff or 0x816f090c2007ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2008ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 8)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2008ffff or 0x816f090c2008ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2009ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 9)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2009ffff or 0x816f090c2009ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-200affff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 10)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c200affff or 0x816f090c200affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-200bffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 11)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c200bffff or 0x816f090c200bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-200cffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 12)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c200cffff or 0x816f090c200cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-200dffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 13)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c200dffff or 0x816f090c200dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-200effff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 14)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c200effff or 0x816f090c200effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-200fffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 15)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c200fffff or 0x816f090c200fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2010ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 16)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2010ffff or 0x816f090c2010ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2011ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 17)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2011ffff or 0x816f090c2011ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2012ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 18)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2012ffff or 0x816f090c2012ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2013ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 19)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2013ffff or 0x816f090c2013ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2014ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 20)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2014ffff or 0x816f090c2014ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2015ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 21)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2015ffff or 0x816f090c2015ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2016ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 22)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2016ffff or 0x816f090c2016ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2017ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 23)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2017ffff or 0x816f090c2017ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f090c-2018ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. (DIMM 24)

    This message is for the use case when an implementation has detected Memory is no longer Throttled.

    May also be shown as 816f090c2018ffff or 0x816f090c2018ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    System - Other
    SNMP Trap ID
    CIM Information
    Prefix: PLAT ID: 0143
    User Response
    No action; information only.
  • 816f0a07-0301ffff : The Processor [ProcessorElementName] is no longer operating in a Degraded State. (CPU 1)

    This message is for the use case when an implementation has detected a Processor is no longer running in the Degraded state.

    May also be shown as 816f0a070301ffff or 0x816f0a070301ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0039
    User Response
    No action; information only.
  • 816f0a07-0302ffff : The Processor [ProcessorElementName] is no longer operating in a Degraded State. (CPU 2)

    This message is for the use case when an implementation has detected a Processor is no longer running in the Degraded state.

    May also be shown as 816f0a070302ffff or 0x816f0a070302ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0039
    User Response
    No action; information only.
  • 816f0a07-2584ffff : The Processor [ProcessorElementName] is no longer operating in a Degraded State. (All CPUs)

    This message is for the use case when an implementation has detected a Processor is no longer running in the Degraded state.

    May also be shown as 816f0a072584ffff or 0x816f0a072584ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Warning - CPU
    SNMP Trap ID
    42
    CIM Information
    Prefix: PLAT ID: 0039
    User Response
    No action; information only. One of CPUs :
  • 816f0a0c-2001ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 1)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2001ffff or 0x816f0a0c2001ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2002ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 2)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2002ffff or 0x816f0a0c2002ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2003ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 3)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2003ffff or 0x816f0a0c2003ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2004ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 4)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2004ffff or 0x816f0a0c2004ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2005ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 5)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2005ffff or 0x816f0a0c2005ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2006ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 6)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2006ffff or 0x816f0a0c2006ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2007ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2007ffff or 0x816f0a0c2007ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2008ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 8)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2008ffff or 0x816f0a0c2008ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2009ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 9)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2009ffff or 0x816f0a0c2009ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-200affff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 10)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c200affff or 0x816f0a0c200affff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-200bffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 11)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c200bffff or 0x816f0a0c200bffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-200cffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 12)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c200cffff or 0x816f0a0c200cffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-200dffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 13)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c200dffff or 0x816f0a0c200dffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-200effff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 14)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c200effff or 0x816f0a0c200effff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-200fffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 15)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c200fffff or 0x816f0a0c200fffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2010ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 16)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2010ffff or 0x816f0a0c2010ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2011ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 17)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2011ffff or 0x816f0a0c2011ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2012ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 18)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2012ffff or 0x816f0a0c2012ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2013ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 19)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2013ffff or 0x816f0a0c2013ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2014ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 20)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2014ffff or 0x816f0a0c2014ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2015ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 21)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2015ffff or 0x816f0a0c2015ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2016ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 22)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2016ffff or 0x816f0a0c2016ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2017ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 23)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2017ffff or 0x816f0a0c2017ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a0c-2018ffff : An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 24)

    This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed.

    May also be shown as 816f0a0c2018ffff or 0x816f0a0c2018ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Temperature
    SNMP Trap ID
    0
    CIM Information
    Prefix: PLAT ID: 0147
    User Response
    No action; information only.
  • 816f0a13-2401ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error. (SMBus)

    This message is for the use case when an implementation has detected that a system has recovered from a Bus Fatal Error.

    May also be shown as 816f0a132401ffff or 0x816f0a132401ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0245
    User Response
    1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat sink and Replacing a microprocessor and heat sink).
    2. If the problem persists and there is no other CPU with the same error indication, replace the system board.
    3. (Trained technician only) Replace the system board (see Removing the system board and Replacing the system board). (n = microprocessor number)
  • 816f0a13-2582ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error. (All PCI Error)

    This message is for the use case when an implementation has detected that a system has recovered from a Bus Fatal Error.

    May also be shown as 816f0a132582ffff or 0x816f0a132582ffff

    Severity
    Info
    Serviceable
    No
    Automatically notify support
    No
    Alert Category
    Critical - Other
    SNMP Trap ID
    50
    CIM Information
    Prefix: PLAT ID: 0245
    User Response
    1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat sink and Replacing a microprocessor and heat sink).
    2. If the problem persists and there is no other CPU with the same error indication, replace the system board.
    3. (Trained technician only) Replace the system board (see Removing the system board and Replacing the system board). (n = microprocessor number)
    One of PCI Error : PCIs :