Skip to main content

202-902-000 : MemStr Test Failed

MemStr Test Failed

Internal Event

No

Severity

Error

Serviceable

Yes

Recoverable

No

Automatically Notify Support

No

User Response

Complete the following steps:

  1. Ensure that all memory is enabled by checking the "Available System Memory" in the "Resource Utilization" section of the DSA Diagnostic Event log.
  2. If necessary, access the Configuration/Setup Utility program by pressing F1 during system boot and enable all memory.
  3. Make sure that the DSA Diagnostic code is at the latest level.
  4. Run the test again.
  5. Execute the standard DSA memory diagnostics to validate all memory.
  6. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.

Date Message Added

09/04/2012

Reviewed

09/04/2012