LCD display panel messages

This section provides descriptions and actions for the messages that might display in the LCD system information display panel on the server.

The LCD system information display panel on the server provides messages about the server progress during POST and the actions plan to follow and correct the problem. Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. For more information about the LCD display panel, see LCD system information display panel.

The following table lists the messages that might display in the LCD display panel on the server.

Table 1. LCD display panel messages.

Three-column table with the LCD display messages and actions to correct the problem

MessageDescriptionAmount of time before the system timeout if no activityAction
SYS OFF/BLK PWRThe system is off; no power permissions granted by IMM.-Normal. No action is required.
SYSTEM OFFThe system is off.-Normal. No action is required.
UEFI: AUTH USERAuthenticating the user.-Normal. No action is required.
UEFI: F1 SETUPWaiting at F1 menu.-Normal. No action is required.
UEFI: BOOT DIAGSThe system is booting to pDSA-Normal. No action is required.
UEFI: BOOT UEFIControl has been passed to the operating system bootloader.-Normal. No action is required.
OPERATING SYS.UEFI has passed control to the operating system.-Normal. No action is required.
UEFI: CSM INITPreparing for legacy boot.-Normal. No action is required.
UEFI: CSM DONEReady to boot legacy.-Normal. No action is required.
IMM: READYIMM is done loading.-Normal. No action is required.
Power Fault XXhA system power fault has occurred.Immediately
  1. Identify the FRU associated with the VRD.
  2. Check the IMM log.
SYSTEM ONThe system is on. The microprocessor has not attempted to fetch from UEFI ROM.After 1 minuteInspect the microprocessor (s).
WAITING ON UEFIUEFI has not fetched code.After 1 minute
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: MEASUR.IMGUEFI is running.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: SIG.CHK.PRVerifying the signature of the primary bank.After 2 minutesFlash the UEFI primary bank.
UEFI: SIG.CHK.BKVerifying the signature of the backup bank.After 2 minutesFlash the UEFI backup bank.
UEFI: UPDATE PRIUEFI is updating the primary bank.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: UPDATE BKPUEFI is updating the backup bank.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: END SECUEFI is running.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: START PEIUEFI is running.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: MEM INITMRC is running.After 2 minutes
  1. Inspect the memory in the compute books.
  2. Check the IMM log.
UEFI: DXE INITDXE is running.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: PECI INITThe PECI data is ready to be read by IMM.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: USB INITThe USB bus is being initialized.After 2 minutes
  1. Inspect the USB subsystem.
  2. Restart the server.
UEFI: PCI INITPCIe initialization is running.After 10 minutesInspect the PCIe subsystem.
UEFI: VIDEO INITVideo initialization is running.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: SMBIOS RDYThe SMBIOS tables are ready to be sent to IMM.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: SMI INSUEFI is running.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
UEFI: BOOTLEGBooting legacy.After 2 minutesMake sure that the boot operating system is installed correctly.
UEFI: UNMAP DSAUEFI is running.After 2 minutes
  1. Restart the server.
  2. Flash the UEFI firmware.
  3. Clear CMOS.
IMM: UBOOTIMM is loading UBOOT.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Reset IMM, see Setup utility menu choices.
  3. Replace the standard I/O book.
IMM: LOADINGIMM is loading the kernel.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Perform a web or inband flash of the IMM firmware using TFTP burn.
IMM: SECURE BOOTIMM is loading the kernel.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Reset IMM, see Setup utility menu choices.
  3. Replace the standard I/O book.
IMM: KERNEL BOOTIMM is loading the kernel.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Reset IMM, see Setup utility menu choices.
  3. Replace the standard I/O book.
IMM: NETWORKIMM is loading the kernel.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Perform a web or inband flash of the IMM firmware using TFTP burn.
IMM: BOOTINGIMM is loading the kernel.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Perform a web or inband flash of the IMM firmware using TFTP burn.
IMM: PWR ACTIONSIMM is loading the kernel.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Perform a web or inband flash of the IMM firmware using TFTP burn.
IMM: THERMALIMM is loading the kernel.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Perform a web or inband flash of the IMM firmware using TFTP burn.
IMM: FLASH MNGRIMM is loading the kernel.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Perform a web or inband flash of the IMM firmware using TFTP burn.
IMM: UEFI SYNCIMM is loading the kernel.After 15 minutes of no activity or 10 IMM reboot cycles
  1. Disconnect the power from the server.
  2. Perform a web or inband flash of the IMM firmware using TFTP burn.