Skip to main content

IMM self tests

Use this information to resolve IMM self-test errors by referencing the error codes and following the suggested corrective actions.

Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
  • See Parts listing to determine which components are consumable, structural, or CRU parts.
  • If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained technician.
Error codeDescriptionAction
166-000-xxxPassed the IMM test.N/A
166-801-xxxIMM test stopped: the IMM returned an incorrect response length.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at (http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter).
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-802-xxxIMM test stopped: the test cannot be completed for an unknown reason.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-803-xxxIMM test stopped: the node is busy; try later.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-804-xxxIMM test stopped: invalid command.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-805-xxxIMM test stopped: invalid command for the given LUN.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-806-xxxIMM test stopped: timeout while processing the command.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-807-xxxIMM test stopped: out of space.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-808-xxxIMM test stopped: reservation canceled or invalid reservation ID.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-809-xxxIMM test stopped: request data was truncated.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-810-xxxIMM test stopped: request data length is invalid.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-811-xxxIMM test stopped: request data field length limit is exceeded.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-812-xxxIMM Test stopped a parameter is out of range.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-813-xxxIMM test stopped: cannot return the number of requested data bytes.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-814-xxxIMM test stopped: requested sensor, data, or record is not present.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-815-xxxIMM test stopped: invalid data field in the request.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-816-xxxIMM test stopped: the command is illegal for the specified sensor or record type.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-817-xxxIMM test stopped: a command response could not be provided.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-818-xxxIMM test stopped: cannot execute a duplicated request.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-819-xxxIMM test stopped: a command response could not be provided; the SDR repository is in update mode.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-820-xxxIMM test stopped: a command response could not be provided; the device is in firmware update mode.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-821-xxxIMM test stopped: a command response could not be provided; IMM initialization is in progress.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-822-xxxIMM test stopped: the destination is unavailable.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-823-xxxIMM test stopped: cannot execute the command; insufficient privilege level.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-824-xxxIMM test stopped: cannot execute the command.
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Rerun the test.
  7. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-901-xxxFailed the IMM test due to a failure in Private bus (BUS 0).
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Turn off the blade server and reseat the blade server in the blade server bay and turn on the blade server. See Removing the blade server from the BladeCenter unit, Installing the blade server in a BladeCenter unit, and Turning on the blade server.
  7. Rerun the test. See Diagnostic tools overview.
  8. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-902-xxxFailed the IMM self test due to a failure in Emulex BE3 bus (BUS 1)
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit for more information.
  2. Wait 45 seconds and reseat the blade server in the blade server bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM and the component firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Turn off the blade server and reseat the blade server in the blade server bay and turn on the blade server.
  7. Rerun the test.
  8. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-903-xxxFailed the IMM self test due to a failure in the DIMM bus (BUS 2).
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade module bay, but do not remove it. See Removing the blade server from the BladeCenter unit for more information.
  2. Reseat the DIMMs (see Removing a memory module and Installing a memory module).
  3. Wait 45 seconds and reseat the blade server in the blade module bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  4. Rerun the test. See Diagnostic tools overview.
  5. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  7. Turn off the blade server and reseat the blade server in the blade server bay and turn on the blade server. See Removing the blade server from the BladeCenter unit for more information.
  8. Rerun the test.
  9. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-904-xxxFailed the IMM self test due to a failure in the Lightpath bus (BUS 3).
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit for more information.
  2. Wait 45 seconds and reseat the blade server in the blade module bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Turn off the blade server and reseat the blade server in the blade server bay and turn on the blade server. See Removing the blade server from the BladeCenter unit for more information.
  7. Rerun the test. See Diagnostic tools overview.
  8. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-906-xxxFailed the IMM self test due to a failure in the DIMM bus (BUS 5).
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade module bay, but do not remove it. See Removing the blade server from the BladeCenter unit for more information.
  2. Reseat the DIMMs (see Removing a memory module and Installing a memory module).
  3. Wait 45 seconds and reseat the blade server in the blade module bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  4. Rerun the test. See Diagnostic tools overview.
  5. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support website at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  7. Turn off the blade server and reseat the blade server in the blade server bay and turn on the blade server. See Removing the blade server from the BladeCenter unit for more information.
  8. Rerun the test.
  9. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.
166-908-xxxFailed the IMM self test due to a failure in the SAS bus (BUS 7).
  1. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it. See Removing the blade server from the BladeCenter unit for more information.
  2. Wait 45 seconds and reseat the blade server in the blade module bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  3. Rerun the test. See Diagnostic tools overview.
  4. Make sure that the DSA Diagnostic code is up-to-date, upgrade if necessary; then, rerun the test. The latest code can be found on the IBM support Web site at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  5. Make sure that the IMM firmware level is up-to-date, upgrade if necessary; then, rerun the test. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. The latest level firmware for this component can be found on the IBM support Web site at http://www-933.ibm.com/ support/fixcentral/systemx/groupView? query.productGroup=ibm%2FBladeCenter.
  6. Turn off the blade server, open the blade server release levers and pull the blade server away from the blade server bay, but do not remove it from the bay. See Removing the blade server from the BladeCenter unit for more information.
  7. Wait 45 seconds and reseat the blade server in the blade module bay and turn on the blade server. See Installing the blade server in a BladeCenter unit and Turning on the blade server.
  8. Rerun the test. See Diagnostic tools overview.
  9. If the failure remains, refer to Removing and replacing blade server components to replace the failed component.