80070101-2c01ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (ML2 OverTemp)
Sensor [SensorElementName] has transitioned from normal to non-critical state. (ML2 OverTemp)
This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.
May also be shown as 800701012c01ffff or 0x800701012c01ffff
Severity
Warning
Alert Category
Warning - Temperature
Serviceable
Yes
SNMP Trap ID
12
Automatically Notify Support
No
User Response
- Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
- Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
- Replace the failed ML2 card.
Give documentation feedback