Installing the Brocade FC switch RCF file

When you configure a Brocade FC switch, you can install the switch configuration files that provide the complete switch settings for certain configurations.

These steps must be repeated on each of the Brocade FC switches in the MetroCluster fabric configuration.

  1. Initiate the download and configuration process: configDownload
    Respond to the prompts as shown in the following example.

    FC_switch_A_1:admin> configDownload
    Protocol (scp, ftp, sftp, local) [ftp]:
    Server Name or IP Address [host]: <user input>
    User Name [user]:<user input>
    Path/Filename [<home dir>/config.txt]:path to configuration file
    Section (all|chassis|switch [all]): all
    .
    .
    .
    Do you want to continue [y/n]: y
    Password: <user input>
    After entering your password, the switch downloads and executes the configuration file.
  2. Persistently enable the switch: switchcfgpersistentenable
    The example shows how to persistently enable FC switch_A_1.

    FC_switch_A_1:admin> switchcfgpersistentenable
  3. Run the following command to confirm that the configuration file has set the switch domain: switchShow
    Each switch is assigned a different domain number depending on which configuration file the switch used.

    FC_switch_A_1:admin> switchShow
    switchName: FC_switch_A_1
    switchType: 109.1
    switchState: Online
    switchMode: Native
    switchRole: Subordinate
    switchDomain: 5
  4. Verify that your switch is assigned the correct domain value as indicated in the following table.
    FabricSwitchSwitch domain
    1A_15
    B_17
    2A_26
    B_28
  5. Change the port speed: portcfgspeed

    FC_switch_A_1:admin> portcfgspeed port number port speed
    Note
    By default, all the ports are configured to operate at 16 Gbps. You might change the port speed for the following reasons:
    • The interconnect switch ports speed should be changed when an 8-Gbps FC-VI adapter is used and the switch port speed should set to 8 Gbps.
    • The switch ports speed should be changed when an 8-Gbps HBA adapter is used for ATTO FibreBridge 6500N.
    • The ISL ports' speed must be changed when the ISL is not capable of running at 16 Gbps.
  6. Calculate the ISL distance.
    Due to the behavior of the FC-VI, you must set the distance to 1.5 times the real distance with a minimum of 10 (LE). The distance for the ISL is calculated as follows, rounded up to the next full kilometer: 1.5 × real distance = distance.

    If the distance is 3 km, then 1.5 × 3 km = 4.5. This is lower than 10; therefore, you must set the ISL to the LE distance level.

    The distance is 20 km, then 1.5 × 20 km = 30. You must set the ISL to the LS distance level.

  7. Set the distance for each ISL port using the following command: portcfglongdistanceport levelvc_link_initdistance
    A vc_link_init value of 1 uses the fillword 'ARB' by default. A value of 0 uses the fillword 'IDLE'. The required value might vary depending on the link you use. In this example, the default is set and the distance is assumed to be 20 km. Hence, the setting is '30' with a vc_link_init value of 1, and the ISL port is 21.

    Example: LS

    FC_switch_A_1:admin> portcfglongdistance 21 LS 1 -distance 30



    Example: LE

    FC_switch_A_1:admin> portcfglongdistance 21 LE 1 
  8. Verify if the IP address is set correctly: ipAddrshow

    FC_switch_A_1:admin> ipAddrshow
    You can set the IP address with the following command if required: ipAddrSet
  9. Set the timezone from the switch prompt: tstimezone --interactive

    You should respond to the prompts as required.

    FC_switch_A_1:admin>  tstimezone --interactive
  10. Reboot the switch: reboot

    The example shows how to reboot FC switch _A_1.

    FC_switch_A_1:admin> reboot
  11. Verify the distance setting: portbuffershow
    A distance setting of LE appears as 10 km.

    FC_Switch_A_1:admin> portbuffershow
    User Port Lx Max/Resv Buffer Needed Link Remaining
    Port Type Mode Buffers Usage Buffers Distance Buffers
    ---- ---- ---- ------- ------ ------- --------- ----------
    ...
    21 E - 8 67 67 30 km
    22 E - 8 67 67 30 km
    ...
    23 - 8 0 - - 466
  12. Reconnect the ISL cables to the ports on the switches where they were removed.
    The ISL cables were disconnected when the factory settings were reset to the default settings.
  13. Validate the configuration.
    1. Verify that the switches form one fabric:switchshow

      The following example shows the output for a configuration that uses ISLs on ports 20 and port 21.

      FC_switch_A_1:admin> switchshow
      switchName: FC_switch_A_1
      switchType: 109.1
      switchState:Online
      switchMode: Native
      switchRole: Subordinate
      switchDomain: 5
      switchId: fffc01
      switchWwn: 10:00:00:05:33:86:89:cb
      zoning: OFF
      switchBeacon: OFF

      Index Port Address Media Speed State Proto
      ===========================================
      ...
      20 20 010C00 id 16G Online FC LE E-Port 10:00:00:05:33:8c:2e:9a "FC_switch_B_1" (downstream)(trunk master)
      21 21 010D00 id 16G Online FC LE E-Port (Trunk port, master is Port 20)
      ...


    2. Confirm the configuration of the fabrics: fabricshow

      FC_switch_A_1:admin> fabricshow
      Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
      -----------------------------------------------------------------
      1: fffc01 10:00:00:05:33:86:89:cb 10.10.10.55 0.0.0.0 "FC_switch_A_1"
      3: fffc03 10:00:00:05:33:8c:2e:9a 10.10.10.65 0.0.0.0 >"FC_switch_B_1"
    3. Very that the ISLs are working: islshow

      FC_switch_A_1:admin> islshow
    4. Confirm that zoning is properly replicated by running the following commands: cfgshowzoneshow
      Both switches in a fabric should have the same zones.
    5. If trunking is used, you can confirm the trunking with the following command: trunkShow

      FC_switch_A_1:admin> trunkshow