Skip to main content

FQXSPPW0063M : Sensor [SensorElementName] has transitioned to critical from a less severe state.

Sensor [SensorElementName] has transitioned to critical from a less severe state.

This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

Severity​

Error

Alert Category​

Critical - Voltage

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0522

SNMP Trap ID​

1

Automatically Notify Support​

Yes

User Action​

Complete the following steps until the problem is solved:

  1. If the specified sensor is Planar 3.3V or Planar 5V, replace the system board (trained technician only).
  2. If the specified sensor is Planar 12V, check XClarity Controller (XCC)event log for power-supply-related issues and resolve those issues. If the problem remains, replace the system board (trained technician only).
  3. Contact local service provider. To locate a reseller authorized by Lenovo to provide warranty service, go to http://www.ibm.com/partnerworld and click Business Partner Locator.