FQXSFMA0049M : DIMM [arg1] disabled due to memory module power failure. DIMM [arg2] detected and good, DIMM [arg3] not detected.
DIMM [arg1] disabled due to memory module power failure. DIMM [arg2] detected and good, DIMM [arg3] not detected.
Parameters
[arg1] Disabled slot
[arg2] Disabled but detected DIMMs
[arg3] Disabled but not detected DIMMs e.g. “DIMM 1,2 disabled due to memory module power failure. DIMM 2 detected and good, DIMM 1 not detected.”
This message is reported when DDRIO power failure detected.
Severity
Warning
User Action
Complete the following steps:
- Power off the system and remove A/C power.
- Check DIMM slots specified in the message. If DIMM installed but undetected, remove it and then restore the A/C power and power on the system.
- If all DIMMs detected or error persists after removing undetected DIMMs, reseat all the DIMMs in the slots specified by the message and then restore the A/C power and power on the system.
- If the problem persists or undetected DIMM needs to be replaced, collect service data logs and contact Lenovo Support.
Envoyer des commentaires