FQXSPCA0017M : PCIe [SensorName] overtemperature has transitioned to critical from a less severe state.
PCIe [SensorName] overtemperature has transitioned to critical from a less severe state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check the XCC event log for any fan or cooling related issues and address them first.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are correctly installed and are in place.
- Make sure that the room temperature is within operating specifications.
- Upgrade all system and chassis (if applicable) firmware to the latest level.
- If the problem persists, collect service data log.
- Contact Lenovo Support.
フィードバックを送る