FQXSPMA0012M : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
Check the event log of XClarity Controller (XCC) for any fan- or cooling-related issues.
Make sure that the airflow at the front and rear of the chassis is not obstructed and arei n place,clean, and correctly installed.
Make sure that the room temperature is within operating specifications.
If the problem remains and no other DIMMs have the same indication, replace the DIMM.
Give documentation feedback