FQXSFIO0008M : An intra-board UPI dynamic link width reduction has been detected on the link between processor [arg1] port [arg2] and processor [arg3] port [arg4].
An intra-board UPI dynamic link width reduction has been detected on the link between processor [arg1] port [arg2] and processor [arg3] port [arg4].
Parameters
[arg1] Socket number, 1-based
[arg2] Port Number
[arg3] Socket number, 1-based
[arg4] Port Number
Severity
Warning
User Action
Complete the following steps:
Power off the system and remove A/C power.
Restore A/C power and power on the system.
If the problem persists, collect Service Data logs and contact Lenovo Support.
NoteThe solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.
Give documentation feedback