Supports RAID levels 0 and 1 for SATA storage including 7mm 2.5-inch solid-state drives and M.2 drives.
Supports RAID levels 0 and 1 for NVMe storage (Intel VROC NVMe RAID).
Note
VROC Intel-SSD-Only supports Intel NVMe drives.
VROC Premium requires an activation key for non-Intel NVMe drives. For more information about acquiring and installing the activation key, see Lenovo Features on Demand website
Video controller (integrated into Lenovo XClarity Controller)
ASPEED
SVGA compatible video controller
Avocent Digital Video Compression
Video memory is not expandable
Note
Maximum video resolution is 1920 x 1200 at 60 Hz.
Input/Output (I/O) features
Node operator panel
USB 3.0 Console Breakout Cable connector
External LCD diagnostics handset connector
One 1 Gb RJ45 Ethernet port with share-NIC feature for Lenovo XClarity Controller
One 25 Gb SFP28 Ethernet port with share-NIC feature for Lenovo XClarity Controller
Note
Lenovo XClarity Controller can be accessed by either RJ45 Ethernet port or SFP28 Ethernet port.
Adjust ambient temperature when specific components are installed:
Keep ambient temperature to 30°C or lower when one or more of the following processors are installed:
Processors with TDP (thermal design power) 165 watts or lower
Keep ambient temperature to 25°C or lower when one or more of the following processors are installed:
Processors with TDP (thermal design power) higher than 165 watts
Intel(R) Xeon(R) Gold 6334 (165 watts, 8 core)
Environment
The ThinkSystem SD630 V2 Compute Node complies with ASHRAE Class A2 specifications.
The ThinkSystem SD630 V2 Compute Node is supported in the following environment:
Air temperature:
Operating: 10°C - 35°C (50°F - 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft)
Solution powered off: 5°C to 45°C (41°F to 113°F)
Maximum altitude: 3,050 m (10,000 ft)
Relative humidity (non-condensing):
Operating: 20% - 80%, maximum dew point: 21°C (70°F)
Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the solution. For information about the limits for particulates and gases, see Particulate contamination.