21070273 : Aux7/Prim8 SIO: Slot Or Connector, transition to Critical from less severe was asserted.

Aux7/Prim8 SIO: Slot Or Connector, transition to Critical from less severe was asserted.

The indicated auxiliary compute node does not acquired power permission since the indicated primary compute node has power faults.

Severity

Error

Alert Category

Node - Node event

SNMP Trap ID

554107507

User Action

  1. Ensure the indicated primary node is power on.
  2. If the event persists, reset the BMC on indicated auxiliary compute node.
  3. If the event persists, ensure the indicated primary compute node is power off, and then reseat it. (Service technician only)
  4. If the event persists, ensure the indicated primary compute node is power off, and then replace the indicated auxiliary compute node. (Service technician only)
  5. If the event persists, please consult with technical service.