Skip to main content

Remove the drip sensor assembly

Use this information to remove the drip sensor assembly.

About this task

S002
disconnect all power
CAUTION
The power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
Attention

Procedure

  1. Make preparations for this task.
    1. ❶ Press down the blue latch and ❷ rotate the top of the shield rearward; then, ❸ lift the shield up to clear the manifold pipe that enters the enclosure.
      Figure 1. Lower left EMC shield removal
      Lower left EMC shield removal
      Note
      If there is a manifold vertical pipe in front of the EMC shield, you need to slide it sideways out from underneath the pipe.
      Figure 2. Lower left EMC shield removal
      Lower left EMC shield removal
  2. Remove the drip sensor assembly.
    1. ❶ Push the latch up upwards.
    2. ❷ Slide the drip sensor assembly backwards, then; lift the drip sensor assembly up to clear sensor post and pull it out of the enclosure.
    Figure 3. Drip sensor assembly removal
    Drip sensor assembly removal
    Figure 4. Drip sensor assembly
    Drip sensor assembly
    Table 1. Drip sensor assembly
    1 Connector2 Latch

After you finish