Skip to main content

FQXSFSR0001M : [arg1] GPT corruption detected, DiskGUID: [arg2]

[arg1] GPT corruption detected, DiskGUID: [arg2]

Severity

Warning

User Action

Complete the following steps:

  1. Remove all the external drives during POST to avoid this event to be falsely triggered.
  2. Check the XCC event log, if this event has a follow-up recovery event log, it means that GTP corruption has been recovered successfully, then ignore this event message and do not perform the remaining steps.
  3. Back up the data disk.
  4. Press F1 Setup->SystemSettings->Recovery->Disk GPT Recovery and set to "Automatic."
  5. Save settings and restart the system.
  6. Boot to F1 setup; the system automatically tries to recover the GPT during the POST.
  7. Restart the system.
  8. Re-format the LUN or disks and re-install the OS.
  9. If the problem persists, collect Service Data logs and contact Lenovo Support.