Power cords

Several power cords are available, depending on the country and region where the server is installed.

To view the power cords that are available for the server:
  1. Go to:

    Data Center Solution Configurator

  2. Click Preconfigured Model or Configure to order.

  3. Enter the machine type and model for your server to display the configurator page.

  4. Click Power > Power Cables to see all line cords.

Note
  • For your safety, a power cord with a grounded attachment plug is provided to use with this product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.

  • Power cords for this product that are used in the United States and Canada are listed by Underwriter's Laboratories (UL) and certified by the Canadian Standards Association (CSA).

  • For units intended to be operated at 115 volts: Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a parallel blade, grounding-type attachment plug rated 15 amperes, 125 volts.

  • For units intended to be operated at 230 volts (U.S. use): Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a tandem blade, grounding-type attachment plug rated 15 amperes, 250 volts.

  • For units intended to be operated at 230 volts (outside the U.S.): Use a cord set with a grounding-type attachment plug. The cord set should have the appropriate safety approvals for the country in which the equipment will be installed.

  • Power cords for a specific country or region are usually available only in that country or region.

DC terminal block cable

Connect the SE350 V2 node to DC power source with ThinkEdge SE350 V2 DC Terminal Block Cable.

  • For more information of ThinkEdge SE350 V2 DC Terminal Block Cable, see Lenovo ServerProven website.

  • Connect the terminal block cable to the power connector and threaded stud at the rear of node. See Rear view to locate the power connector and threaded stud.

  • For proper connection between DC power source and the terminal block cable, refer to the following information:

    Table 1. ThinkEdge SE350 V2 DC Terminal Block Cable pin assignment
    FromLabelWire typeWire color
    Power connector1PositiveRed
    Power connector2PositiveRed
    Power connector3PositiveRed
    Power connector4NegativeBlack
    Power connector5NegativeBlack
    Power connector6NegativeBlack
    Threaded studN/AGroundingYellow/Green