Parts list

Use the parts list to identify each of the components that are available for your server.

For more information about ordering parts:
  1. Go to Lenovo Data Center Support and navigate to the support page for the specific server.

  2. Click Parts.

  3. Enter the serial number to view a listing of parts for the specific server.

It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.

Note
Depending on the model, your server might look slightly different from the illustration.
The parts listed in the following table are identified as one of the following:
  • T1: Tier 1 customer replaceable unit (CRU). Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request with no service agreement, you will be charged for the installation.
  • T2: Tier 2 customer replaceable unit (CRU). You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.
  • F: Field replaceable unit (FRU). FRUs must be installed only by trained service technicians.
  • C: Consumable and Structural parts. Purchase and replacement of consumable and structural parts is your responsibility. If Lenovo acquires or installs a structural component at your request, you will be charged for the service.

Enclosure components

Figure 1. Enclosure components
Enclosure components
Table 1. Enclosure parts listing
DescriptionTypeDescriptionType
1 Power adapter support bracketT14 Enclosure bracket dust filter setT1
2 ThinkEdge SE350 V2 EnclosureF5 Node dummy fillerT1
3 Enclosure front shipping bracketT1  

Node components

Figure 2. Server components
Server components
DescriptionTypeDescriptionType
1 ThinkEdge 300W 230V/115V external power adapterT120 MicroSD cardT1
2 Cable wallT121 25GbE/10GbE front I/O bezel T1
3 12-48V DC power module boardF22 1GbE front I/O bezel T1
4 Top coverT123 I/O fillersC
5 Memory moduleT224 CMOS battery (CR2032)C
6 FanT125 Node chassisF
7 System board with processorF26 Front operator panel assemblyF
8 Anti-tampering keylock switch bracketT127 7mm 2.5-inch drive fillerC
9 Anti-tampering keylock switch with cableT228 7mm 2.5-inch hot-swap driveT1
10 DC power input board moduleF29 15mm 2.5-inch drive fillerC
11 Processor heat sinkF30 15mm 2.5-inch hot-swap driveT1
12 Air baffleT131 7mm drive cageT1
13 Bridge boardF32 Kensington lock (exterior)T1
14 15mm/7mm Drive Backplane 1 (lower)F33 CablesT1
15 7mm Drive Backplane 2 (upper)F34 15mm drive cageT1
16 1GbE I/O module boardF35 AC power input board moduleF
17 10/25GbE I/O module boardF36 Internal power supply unit (AC power module board)F
18 M.2 heat sinkF37 Intrusion switch holderT2
19 M.2 boot driveT138 Intrusion switch with cableT2