Skip to main content

FQXSPCA0017M : Sensor [SensorElementName] has transitioned to critical from a less severe state.

Sensor [SensorElementName] has transitioned to critical from a less severe state.

This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0522

SNMP Trap ID

0

Automatically Notify Support

No

User Action

Complete the following steps:

  1. Check the event log of XClarity Controller for any fan or cooling-related issues or power-related issues.
  2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place, clean, and correctly installed.
  3. Make sure that the room temperature is within operating specifications.