Skip to main content

Observable problems

Use this information to solve observable problems.

Compute node hangs during the UEFI boot process

If the system hangs during the UEFI boot process with the message UEFI: DXE INIT on the display, make sure that Option ROMs were not configured with a setting of Legacy. You can remotely view the current settings for Option ROMs by running the following command using the Lenovo XClarity Essentials OneCLI:

onecli config show EnableDisableAdapterOptionROMSupport --bmc xcc_userid:xcc_password@xcc_ipaddress

To recover a system that hangs during the boot process with Legacy Option ROM settings, see the following Tech Tip:

ThinkSystem server hangs during UEFI boot with "UEFI:DXE INIT" when option ROM settings configured for legacy

If legacy Option ROMs must be used, do not set slot Option ROMs to Legacy on the Devices and I/O Ports menu. Instead, set slot Option ROMs to Auto (the default setting), and set the System Boot Mode to Legacy Mode. Legacy option ROMs will be invoked shortly before the system boots.

The compute node immediately displays the POST Event Viewer when it is turned on

Complete the following steps until the problem is solved.
  1. Correct any errors that are indicated by the light path diagnostics LEDs.

  2. Make sure that the compute node supports all the processors and that the processors match in speed and cache size.

    You can view processor details from system setup.

    To determine if the processor is supported for the compute node, see Lenovo ServerProven website.

  3. (Trained technician only) Make sure that processor 1 is seated correctly

  4. (Trained technician only) Remove processor 2 and restart the compute node.

  5. Replace the following components one at a time, in the order shown, restarting the compute node each time:

    1. (Trained technician only) Processor

    2. (Trained technician only) System board

Compute node is unresponsive (POST is complete and operating system is running)

Complete the following steps until the problem is solved.
  • If you are in the same location as the compute node, complete the following steps:

    1. If you are using a KVM connection, make sure that the connection is operating correctly. Otherwise, make sure that the keyboard and mouse are operating correctly.

    2. If possible, log in to the compute node and verify that all applications are running (no applications are hung).

    3. Restart the compute node.

    4. If the problem remains, make sure that any new software has been installed and configured correctly.

    5. Contact your place of purchase of the software or your software provider.

  • If you are accessing the compute node from a remote location, complete the following steps:

    1. Make sure that all applications are running (no applications are hung).

    2. Attempt to log out of the system and log back in.

    3. Validate the network access by pinging or running a trace route to the compute node from a command line.

      1. If you are unable to get a response during a ping test, attempt to ping another compute node in the enclosure to determine whether it is a connection problem or compute node problem.

      2. Run a trace route to determine where the connection breaks down. Attempt to resolve a connection issue with either the VPN or the point at which the connection breaks down.

    4. Restart the compute node remotely through the management interface.

    5. If the problem remains, verify that any new software has been installed and configured correctly.

    6. Contact your place of purchase of the software or your software provider.

Voltage planar fault is displayed in the event log

Complete the following steps until the problem is solved.
  1. Revert the system to the minimum configuration. See Specifications for the minimally required number of processors and DIMMs.

  2. Restart the system.

    • If the system restarts, add each of the removed items one at a time and restart the system each time until the error occurs. Replace the item for which the error occurs.

    • If the system does not restart, suspect the system board.

Unusual smell

Complete the following steps until the problem is solved.

  1. An unusual smell might be coming from newly installed equipment.
  2. If the problem remains, contact Lenovo Support.

Compute node seems to be running hot

Complete the following steps until the problem is solved.

Multiple compute nodes or chassis:

  1. Make sure that the room temperature is within the specified range (see Specifications).
  2. Check the management processor event log for rising temperature events. If there are no events, the compute node is running within normal operating temperatures. Note that you can expect some variation in temperature.

Cannot enter legacy mode after installing a new adapter

Complete the following procedure to solve the problem.

  1. Go to UEFI Setup > Devices and I/O Ports > Set Option ROM Execution Order.
  2. Move the RAID adapter with operation system installed to the top of the list.
  3. Select Save.
  4. Reboot the system and auto boot to operation system.

Cracked parts or cracked chassis

Contact Lenovo Support.