Skip to main content

FQXSPPW0101J : Redundancy Degraded for [RedundancySetElementName] has asserted.

Redundancy Degraded for [RedundancySetElementName] has asserted.

This message is for the use case when Redundancy Degraded has asserted.

Severity

Warning

Alert Category

Warning - Redundant Power Supply

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0804

SNMP Trap ID

10

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Check if one of power supplies is missing, failed or not installed properly. If so, re-install it.
  2. Check the power supply max rate and power capping policy. If the required power resource is not met, change the power supply or modify power capping mechanism.
  3. Upgrade all system and chassis (if applicable) firmware to the latest level.
    Note
    If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before the update.
  4. Collect Service Data log.