FQXSPUN0041J : Redundancy Degraded for [RedundancySetElementName] has asserted.

Redundancy Degraded for [RedundancySetElementName] has asserted.

This message is for the use case when Redundancy Degraded has asserted.

Severity

Warning

Alert Category

Warning - Other

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0804

SNMP Trap ID

60

Automatically Notify Support

No

User Action

Complete the following steps until the problem is solved:

  1. Check the LEDs on the PSU:
    1. If AC LED is not lit, check power cord and input voltage;
    2. If DC LED is not lit, remove and re-install power supply.
  2. The total maximum power required by the solution exceeds the capability of PSUs. Change PSU configuration mode to no redundancy.
  3. Consider reconfiguring the solution with larger power rating PSU's.
  4. If problem persists, collect Service Data log.