FQXSPPW0061M : Sensor [SensorElementName] has transitioned to critical from a less severe state.

Sensor [SensorElementName] has transitioned to critical from a less severe state.

This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

Severity​

Error

Alert Category​

Critical - Power

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0522

SNMP Trap ID​

4

Automatically Notify Support​

No

User Action​

Complete the following steps until the problem is solved:

  1. Check the LED's on the PSU:
    1. if AC LED is not lit, check power cord and input voltage
    2. if DC LED is not lit, remove and re-install power supply
  2. If problem persists, collect Service Data log.