Skip to main content

FQXSPUN0041J : Redundancy Degraded for [RedundancySetElementName] has asserted.

Redundancy Degraded for [RedundancySetElementName] has asserted.

This message is for the use case when Redundancy Degraded has asserted.

Severity​

Warning

Alert Category​

Warning - Other

Serviceable​

Yes

CIM Information​

Prefix:PLAT

and ID:0804

SNMP Trap ID​

60

Automatically Notify Support​

No

User Action​

Complete the following steps until the problem is solved:

  1. Check the LEDs on the PSU:
    1. If AC LED is not lit, check power cord and input voltage;
    2. If DC LED is not lit, remove and re-install power supply.
  2. The total maximum power required by the solution exceeds the capability of PSUs. Change PSU configuration mode to no redundancy.
  3. Consider reconfiguring the solution with larger power rating PSU's.
  4. If problem persists, collect Service Data log.
  5. Contact Lenovo Support.