FQXSPPW0104J : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted.
Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or Fully Redundant to Non-redundant:Sufficient.
Severity
Warning
Alert Category
Warning - Redundant Power Supply
Serviceable
Yes
SNMP Trap ID
10
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check the LED's on the PSU:
- if AC LED is not lit, check power cord and input voltage
- if DC LED is not lit, remove and re-install power supply
- If problem persists, collect Service Data log.
- Contact Lenovo Support.
Give documentation feedback