2.5-inch (8 SAS/SATA)
Configuration | Rear BP | Storage controller | ||
Qty. | Type | Qty. | Type | |
Config. 1 | ||||
Config. 2 | 1 | SFF 8i RAID/HBA | ||
Config. 3 | 1 | CFF 8i/16i RAID/HBA | ||
Config. 4 | 1 | 2 x 2.5" SAS/SATA | ||
Config. 5 | 1 | 2 x 2.5" SAS/SATA | 1 | SFF 8i RAID |
Config. 6 | 1 | 2 x 2.5" SAS/SATA | 1 | CFF 16i RAID/HBA |
Depending on your server configurations, refer to one of the following sections for cable routing information.
Configuration 1 – 3:
Front BP: 8 x 2.5'' SAS/SATA BP
Config. | Front BP | System board | Storage controller | |
SFF 8i RAID/HBA | CFF 8i/16i RAID/HBA | |||
1 | SAS 0 | PCIe 2 | ||
SAS 1 | PCIe 4 | |||
2 | SAS 0, SAS 1 | Gen 4: C 0 Gen 3: C 0, C 1 | ||
3 | SAS 0 | C 0 | ||
SAS 1 | C 1 | |||
| MB |
Example
Figure 1. Configuration 2
Configuration 4 – 6:
Front BP: 8 x 2.5'' SAS/SATA BP
Rear BP: 2 x 2.5'' SAS/SATA BP
Config. | Front BP | Rear BP | System board | Storage controller | |
SFF 8i RAID | CFF 16i RAID/HBA | ||||
4 | SAS 0 | PCIe 2 | |||
SAS 1 | PCIe 4 | ||||
SAS | PCIe 5 | ||||
5 | SAS 0, SAS 1 | Gen 4: C 0 Gen 3: C 0, C 1 | |||
SAS | PCIe 5 | ||||
6 | SAS 0 | C 0 | |||
SAS 1 | C 1 | ||||
PCIe 8 | MB | ||||
SAS | C 3 |
Example
Figure 2. Configuration 6
Give documentation feedback