Skip to main content

2.5-inch (10 AnyBay)

ConfigurationRear BPStorage controller
Qty.TypeQty.Type
Config. 1  1SFF 16i RAID/HBA
Config. 21SFF 16i RAID(Tri-mode)
Config. 312 x 2.5" SAS/SATA1SFF 16i RAID/HBA
Config. 412 x 2.5" NVMe1SFF 16i RAID/HBA
Depending on your server configurations, refer to one of the following sections for cable routing information.

Configuration 1:

Front BP: 10 x 2.5'' AnyBay BP

Note
Connectors marked with asterisk (*) are NOT needed for single CPU configuration.
Config.Front BPSystem boardStorage controller
SFF 16i RAID/HBASFF 16i RAID(Tri-mode)
1NVMe 0-1PCIe 1, PCIe 2  
NVMe 2-3PCIe 3  
*NVMe 4-5*PCIe 7  
*NVMe 6-7*PCIe 8  
*NVMe 8-9*PCIe 6  
SAS 0, SAS 1 

Gen 4: C 0

Gen 3: C 0, C 1

 
SAS 2 Gen 3: C 2 
2SAS 0, SAS 1  

Gen 4: C 0

SAS 2  

Gen 4: C 1

Example

Figure 1. Configuration 1
Cable routing for configuration 1

Configuration 2 – 3:

Front BP: 10 x 2.5'' AnyBay BP

Rear BP: 2 x 2.5'' NVMe BP/ 2 x 2.5'' SAS/SATA BP

Config.Front BPRear BPSystem boardStorage controller
SFF 16i RAID/HBA
3NVMe 0-1 PCIe 1, PCIe 2 
NVMe 2-3 PCIe 3 
NVMe 4-5 PCIe 7 
NVMe 6-7 PCIe 8 
NVMe 8-9 PCIe 6 
SAS 0, SAS 1  

Gen 4: C 0

Gen 3: C 0, C 1

SAS 2SAS 

Gen 4: C 1

Gen 3: C 2, C 3

4NVMe 0-1 PCIe 1, PCIe 2 
NVMe 2-3 PCIe 3 
NVMe 4-5 PCIe 7 
NVMe 6-7 PCIe 8 
NVMe 8-9 PCIe 6 
SAS 0, SAS 1  

Gen 4: C 0

Gen 3: C 0, C 1

SAS 2  

Gen 4: C 1

Gen 3: C 2

 NVMe 0, NVMe 1PCIe 9 

Example

Figure 2. Configuration 3
Cable routing for configuration 3