UC, dissipateur thermique et combinaisons de ventilateurs
Modèles : 4 x 2,5 pouces
CPU group | Config. | Heat sink | Fan |
Z/X | All configurations | Performance | Performance |
Modèles : 8 x 2,5 pouces / 4 x 3,5 pouces
CPU group | Config. | Heat sink | Fan |
C | Non Mellanox ConnextX-6 NIC | Aluminum | Standard |
All other configurations | Aluminum | Performance | |
B | Non Mellanox ConnextX-6 NIC | Aluminum | Standard |
All other configurations | Aluminum | Performance | |
A | All configurations | Standard | Performance |
D | All configurations | Performance | Performance |
Modèles : 10 x 2,5 pouces
CPU group | Config. | Heat sink | Fan |
C | Non Mellanox ConnextX-6 NIC | Aluminum | Standard |
All other configurations | Aluminum | Performance | |
B | All configurations | Aluminum | Performance |
A | All configurations | Standard | Performance |
D | All configurations | Performance | Performance |
Remarque
Une UC requiert 6 ventilateurs (emplacements 1 à 6) et 2 ventilateurs factices (emplacements 7 à 8) ; deux UC nécessitent 8 ventilateurs (emplacements 1 à 8).
Si un adaptateur Ethernet OCP 3.0 est installé, lorsque le système est mis hors tension mais encore branché sur le secteur, les ventilateurs 5 et 6 continuent de tourner à une vitesse nettement inférieure. Il s'agit de la conception système pour assurer le refroidissement approprié de l'adaptateur Ethernet OCP 3.0.
Envoyer des commentaires